EN 60255-22-6-2001 en Electrical Relays - Part 22-6 Electrical Disturbance Tests for Measuring Relays and Protection Equipment - Immunity to Conducted Disturbances Induced by Radio.pdf
《EN 60255-22-6-2001 en Electrical Relays - Part 22-6 Electrical Disturbance Tests for Measuring Relays and Protection Equipment - Immunity to Conducted Disturbances Induced by Radio.pdf》由会员分享,可在线阅读,更多相关《EN 60255-22-6-2001 en Electrical Relays - Part 22-6 Electrical Disturbance Tests for Measuring Relays and Protection Equipment - Immunity to Conducted Disturbances Induced by Radio.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD Electrical relays - Part 22-6: Electrical disturbance tests for measuring relays and protection equipment - Immunity to conducted disturbances induced by radio frequency fields The European Standard EN 60255-22-6:2001 has the status of a British Standard ICs 29.120.70 BS EN 60 2 5 5
2、-2 2-6: 2001 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW COPYRIGHT European Committee for Electrotechnical StandardizationLicensed by Information Handling ServicesBS EN 60255-22-6:2001 National foreword This British Standard, having been prepared under the direction of the
3、 Electrotechnical Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15 August 2001 This British Standard is the official English language version of EN 60255-22- 6:2001. It is identical with IEC 60255-22-6:2001. The UK participation in its prepar
4、ation was entrusted to Technical Committee PEU95, Measuring relays and protection systems, which has the responsibility to: - - aid enquirers to understand the text; present to the responsible internationallEuropean committee any enquiries on the interpretation, or proposals for change, and keep the
5、 UK interests informed; monitor related international and European developments and promulgate them in the UK. - A list of organizations represented on this committee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number.
6、 For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references i ne DrlLlSII 3LauuarUb w 1111 pleriieiit itemtind or UUrpea: publications referred
7、 to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contr
8、act. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. e mi . n *L:-I- OA.-A-A- -i-: I :- Summary of pages This document comprises a front cover, an inside front cover, the EN title
9、page, pages 2 to 12, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. I Date I Comments O BSI 07-2001 ISBN O 580 38103 X COPYRIGHT European Committee for Electrotechnical
10、 StandardizationLicensed by Information Handling ServicesI EUROPEAN STANDARD NORME EUROPEENNE EUROPISCHE NORM EN 60255-22-6 June 2001 ICs 29.120.70 English version E I ect ri ca I re I a ys Part 22-6: Electrical disturbance tests for measuring relays and protection equipment - Immunity to conducted
11、disturbances induced by radio frequency fields (IEC 60255-22-612001) Relais lectriques Elektrische Relais Partie 22-6: Essais dinfluence lectrique concernant les relais de mesure et dispositifs de protection - Immunits aux perturbations conduites induites par des champs radiolectriques (CE1 60255-22
12、-612001) Felder Teil 22-6: Prfungen der elektrischen Strfestigkeit von Merelais und Schutzeinrichtungen - Strfestigkeit gegen leitungsgefhrte Strgren, induziert durch hochfrequente (IEC 60255-22-612001) This European Standard was approved by CENELEC on 2001-0501. CENELEC members are bound to comply
13、with the CEWCENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Upto-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretar
14、iat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the
15、official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committe
16、e for Eledrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Bmssels 0 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC mem
17、bers. . Ref. No. EN 60255-22-6:2001 E COPYRIGHT European Committee for Electrotechnical StandardizationLicensed by Information Handling ServicesI Page 2 EN 60255-22-62001 Foreword The text of document 95/112/FDIS, future edition 1 of IEC 60255-22-6, prepared by IEC TC 95, Measuring relays and protec
18、tion equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60255-22-6 on 2001 -05-01. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement - lates
19、t date by which the national standards conflicting with the EN have to be withdrawn Annexes designated “normative“ are part of the body of the standard. In this standard, annex ZA is normative. Annex ZA has been added by CENELEC. (dop) 2002-02-01 (dow) 2002-02-01 Endorsement notice The text of the I
20、nternational Standard IEC 60255-22-6:2001 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60255-22-3 NOTE: Harmonized as EN 60255-22-3:2000 (not modified). IEC 61
21、0004-3 NOTE: Harmonized as EN 610004-3:1996 (modified). O BSI 07-2001 COPYRIGHT European Committee for Electrotechnical StandardizationLicensed by Information Handling ServicesI Page 3 EN 60255-22-62001 ELECTRICAL RELAYS - Part 22-6: Electrical disturbance tests for measuring relays and protection e
22、quipment - Immunity to conducted disturbances induced by radio frequency fields 1 Scope and object This part of IEC 60255 is based on IEC 61000-4-6, referring to that standard where applicable. It specifies the general requirements for conducted disturbances induced by electromagnetic fields for mea
23、suring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test (EUT) will operate correctly when energized and subjected to conducted
24、 disturbances induced by radiofrequency fields within the frequency range 150 kHz to 80 MHz. NOTE IEC 60255-22-3 (based on IEC 61000-4-3) will specify the immunity requirements of measuring relays and protection equipment over the frequency range of 80 MHz to 1 O00 MHz. The requirements specified in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN602552262001ENELECTRICALRELAYSPART226ELECTRICALDISTURBANCETESTSFORMEASURINGRELAYSANDPROTECTIONEQUIPMENTIMMUNITYTOCONDUCTEDDISTURBANCESINDUCEDBYRADIOPDF

链接地址:http://www.mydoc123.com/p-717762.html