EN 60076-10-2001 en Power Transformers Part 10 Determination of Sound Levels (Remains Current)《电源变压器 第10部分 声级测定 IEC 60076-10-2001 替代 EN60551-1992+A1-1997》.pdf
《EN 60076-10-2001 en Power Transformers Part 10 Determination of Sound Levels (Remains Current)《电源变压器 第10部分 声级测定 IEC 60076-10-2001 替代 EN60551-1992+A1-1997》.pdf》由会员分享,可在线阅读,更多相关《EN 60076-10-2001 en Power Transformers Part 10 Determination of Sound Levels (Remains Current)《电源变压器 第10部分 声级测定 IEC 60076-10-2001 替代 EN60551-1992+A1-1997》.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD Power transformers - Part 10: Determination of sound levels The European Standard EN 60076-10:2001 has the status of a British Standard ICs 29.180 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMiTTED BY COPYRIGHT LAW BS EN IEC 60 O 76-1 0:200 1 60076-10:ZOOl BS EN 60076-10:2001 Amd
2、. No. National foreword Date Comments This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee title, was published under the authority of the Standards Policy and Strategy Committee on 5 September 2001 0 ES1 5 September 2001 This B
3、ritish Standard is the official English language version of EN 60076-10:2001. It is identical with IEC 60076-10:2001. It supersedes BS EN 60551:1993 which is withdrawn. The UK participation in its preparation was entrusted to Technical Committee PELI14, Power transformers, which has the responsibili
4、ty to: - - aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. - A li
5、st of organizations represented on this committee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numb
6、ering system to the other, publications may contain identifiers from both systems. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standard
7、s Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include ail the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard
8、does not of itselfconfer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 35 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. 2 ISBN O 580 3828
9、4 2 EUROPEAN STANDARD EN 60076-10 NORME EUROPENNE EUROPISCHE NORM July 2001 ICs 29.180 Supersedes EN 60551:1992 +A1:1997 English version Power transformers Part IO: Determination of sound levels (IEC 60076-1 0:ZOOI) Transformateurs de puissance Partie 1 O: Dtermination des niveaux de bruit (CE1 6007
10、6-10:2001) Leistungstransformatoren Teil IO: Bestimmung der Geruschpegel (IEC 60076-10:2001) This European Standard was approved by CENELEC on 2001-06-01. CENELEC members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for giving this European Standard the
11、 status of a national standard without any alteration. Up-to-date lists and bibliographiml references concerning such national standards may be obtained on application to the Central secretariat or to any CENELEC member. This European Standard exists in three offiaal versions (English, French, Germa
12、n). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Rep
13、ublic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr
14、Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 0 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide far CENELEC members. Ref. No. EN 60076-10:2001 E EN 60076-1O:ZOOl Foreword The text of document 14/390/FDIS, future edition
15、 1 of IEC 60076-10, prepared by IEC TC 14, Power transformers, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60076-10 on 2001-06-01. This European Standard supersedes EN 60551 :I992 + A1:1997. The following dates were fixed: 2 - latest date by which the EN has to b
16、e implemented at national level by publication of an identical national standard or by endorsement - latest date by which the national standards conflicting with the EN have to be withdrawn Annexes designated “normative“ are pari of the body of the standard. Annexes designated “informative” are give
17、n for information only. in this standard, annex ZA is normative and annexes A and B are informative. Annex ZA has been added by CENELEC. (dop) 2002-03-01 (dOW) 2004-06-01 Endorsement notice The text of the International Standard IEC 60076-10:2001 was approved by CENELEC as a European Standard withou
18、t any modification. EN 60076-10:2001 CONTENTS INTRODUCTION 4 Scope 6 Normative references . 6 Definitions . 7 instrumentation and calibration 8 Choice of test method 8 Load conditions . 8 6.1 General 8 6.2 6.3 6.4 Reduced-load current 10 Principal radiating surface 10 7.1 General . 10 7.2 Transforme
19、rs with or without cooling auxiliaries, dry-type transformers in enclosures and dry-type transformers with cooling auxiliaries inside the enclosure 10 7.3 Cooling auxiliaries mounted on a separate structure spaced 23 m away from the principal radiating surface of the transformer . 10 7.4 Prescribed
20、contour 11 Microphone positions 11 No-load current and rated voltage . 9 Rated current and short-circuit voltage . 9 Dry-type transformers without enclosures 1 0 10 Calculation of the area of the measurement surface 11 10.1 Measurements made at O, 3 m from the principal radiating surface . 11 10.2 M
21、easurements made at 2 m from the principal radiating surface 12 10.3 Measurements made at 1 m from the principal radiating surface 12 10.4 Measurements on test objects where safety clearance considerations require a measurement distance which for all or part of the prescribed contour(s) exceeds the
22、provisions of 10.1 to 10.3 . 12 11 Sound pressure method 12 1 I .I Test environment . 12 11.2 Sound pressure level measurements . 15 11.3 Calculation of average sound pressure level 15 12 Sound intensity method 17 12.1 Test environment . 17 12.2 Sound intensity level measurements 17 12.3 Calculation
23、 of average sound intensity level 17 13 Calculation of sound power level . 18 14 Addition of no-load and load current sound power levels . 19 15 Far-field calculations . 19 16 Presentation of results 19 Annex A (informative) Narrow-band and time-synchronous measurements . 28 Annex 6 (informative) Ty
24、pical report of sound level determination 30 Annex ZA (normative) Normative references to international publications with their corresponding European publications . 35 0 BSI 5 September 2001 EN 60076-10:2001 I NTROD U CT I ON One of the many parameters to be considered when designing and siting tra
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN60076102001ENPOWERTRANSFORMERSPART10DETERMINATIONOFSOUNDLEVELSREMAINSCURRENT 电源变压器 10 部分 声级 测定 IEC60076102001

链接地址:http://www.mydoc123.com/p-717536.html