EN 50397-2-2009 en Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2 Accessories for covered co.pdf
《EN 50397-2-2009 en Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2 Accessories for covered co.pdf》由会员分享,可在线阅读,更多相关《EN 50397-2-2009 en Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2 Accessories for covered co.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationCovered conductors for overheadlines and the related accessoriesfor rated voltages above 1 kV ACand not exceeding 36 kV AC Part 2: Accessories for covered conductors Tests and ac
2、ceptance criteriaBS EN 50397-2:2009National forewordThis British Standard is the UK implementation of EN 50397-2:2009.The UK participation in its preparation was entrusted by Technical CommitteeGEL/20, Electric cables, to Subcommittee GEL/20/11, Cable accessories.A list of organizations represented
3、on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 56671 4ICS 29.240.20Compliance with a British Standard cannot confer immunity
4、 fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 January 2010Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 50397-2:2009EUROPEAN STANDARD EN 50397-2 NORME EUROPENNE EUROPISCHE NORM
5、October 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any mean
6、s reserved worldwide for CENELEC members. Ref. No. EN 50397-2:2009 E ICS 29.240.20 English version Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2: Accessories for covered conductors - Tests and acceptance criteri
7、a Conducteurs gains pour lignes ariennes et accessoires associs pour des tensions assignes suprieures 1 kV c.a. et ne dpassant pas 36 kV c.a - Partie 2: Accessoires pour conducteurs gains - Exigences et essais Kunststoffumhllte Leiter und zugehrige Armaturen fr Freileitungen mit Nennspannungen ber 1
8、 kV und nicht mehr als 36 kV Wechselspannung - Teil 2: Armaturen fr kunststoffumhllte Freileitungsseile - Prfungen und Anforderungen This European Standard was approved by CENELEC on 2009-04-22. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditi
9、ons for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in thre
10、e official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnica
11、l committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and t
12、he United Kingdom. BS EN 50397-2:2009EN 50397-2:2009 2 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric cables. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50397-2 on 2009-04-22. The following dates were fixe
13、d: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-05-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-05-01 EN 50397 consists of two parts: Part 1
14、“Covered Conductors“ and Part 2 “Accessories“. It covers the construction, performance and test acceptance criteria for covered conductors for overhead lines having a nominal voltage above 1 kV a.c. up to and including 36 kV a.c., and for the related accessories. This European Standard EN 50397-2 co
15、vers the accessories. NOTE It has been assumed in the preparation of this document that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. WARNING This European Standard calls for the use of substances and/or proce
16、dures that may be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does not absolve the user from legal obligations relating to health and safety at any stage. _ BS EN 50397-2:2009 3 EN 50397-2:2009 Contents Introduction. 5 1 Scope . 6 2 Normativ
17、e references . 6 3 Terms and definitions . 6 4 Requirements . 8 4.1 General requirements 8 4.2 Specific requirements for fittings used on covered conductor 8 4.3 Marking . 10 5 Quality assurance . 10 6 Classification of tests Type tests, sample tests, routine tests . 10 6.1 Type tests . 10 6.2 Sampl
18、e tests . 11 6.3 Routine tests . 11 7 Tests 11 7.1 Visual examination 12 7.2 Dimensional and material verification 12 7.3 Test for permanent marking . 12 7.4 Mechanical tests . 12 7.5 Hot dip galvanizing test . 31 7.6 Water tightness test for IPC . 31 7.7 Electrical ageing test for connectors 32 7.8
19、 Short-circuit test on APD or EPD . 32 7.9 Power arc test . 33 7.10 Environmental test for suspension and tension clamps 34 7.11 Environmental tests for connectors 36 Annex A (normative) Type tests, sample tests and routine tests 39 Annex B (informative) Example of sampling with inspection by attrib
20、utes 40 Annex C (informative) Example of sampling with inspection by variable 41 Bibliography 42 BS EN 50397-2:2009EN 50397-2:2009 4 Figures Figures 1 - Test arrangement for damage and failure load test . 14 Figures 2 - Test arrangement of slip test at ambient temperature 15 Figures 3 - Slip test ar
21、rangement at low temperature 17 Figure 4 - Lift and side load test 20 Figure 5 - Tensile test arrangement 22 Figure 6 - Arrangement for the low temperature zone . 23 Figure 7 - Test arrangement . 29 Figure 8 - Mechanical stresses on earth parking device 31 Figure 9 - Test arrangement for water tight
22、ness test . 32 Figure 10 - Resistance measurement 33 Figure 11 - Example of power arc test arrangement for arc protection system . 34 Tables Table 1 - Specified minimum loads . 19 Table A.1 39 BS EN 50397-2:2009 5 EN 50397-2:2009 Introduction Covered conductors consist of a conductor surrounded by a
23、 covering made of insulating material as protection against accidental contacts with other covered conductors and with grounded parts such as tree branches, etc. In comparison with insulated conductors, this covering has reduced properties, but is able to withstand the phase-to-earth voltage tempora
24、rily. Since covered conductors are unscreened, they are not touch-proof, i.e. they must be treated as bare conductors with respect to electric shock. EN 50397-2 does not cover aspects related to the installation of overhead lines such as determination of clearances, spans, sags, etc. BS EN 50397-2:2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN5039722009ENCOVEREDCONDUCTORSFOROVERHEADLINESANDTHERELATEDACCESSORIESFORRATEDVOLTAGESABOVE1KVACANDNOTEXCEEDING36KVACPART2ACCESSORIESFORCOVEREDCOPDF

链接地址:http://www.mydoc123.com/p-717104.html