EN 50216-2-2002 en Power transformer and reactor fittings Part 2 Gas and oil actuated relay for liquid immersed transformers and reactors with conservator (Incorporates Amendment A.pdf
《EN 50216-2-2002 en Power transformer and reactor fittings Part 2 Gas and oil actuated relay for liquid immersed transformers and reactors with conservator (Incorporates Amendment A.pdf》由会员分享,可在线阅读,更多相关《EN 50216-2-2002 en Power transformer and reactor fittings Part 2 Gas and oil actuated relay for liquid immersed transformers and reactors with conservator (Incorporates Amendment A.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 50216-2:2002 Incorporating Amendment No. 1 Power transformer and reactor fittings Part 2: Gas and oil actuated relay for liquid immersed transformers and reactors with conservator The European Standard EN 50216-2:2002, with the incorporation of amendment A1:2002, has the statu
2、s of a British Standard ICS 29.120.70; 29.180 BS EN 50216-2:2002 This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 12 April 2002 BSI 4 Novem
3、ber 2003 ISBN 0 580 39499 9 National foreword This British Standard is the official English language version of EN 50216-2:2002, including amendment A1:2002. The UK participation in its preparation was entrusted to Technical Committee PEL/14, Power transformers, which has the responsibility to: A li
4、st of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standa
5、rds Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard
6、does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and
7、 promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 11 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No.
8、Date Comments 14729 4 November 2003 Changes to Table 6EUROPEAN STANDARD EN 50216-2 January 2002 NORME EUROPENNE + A1 December 2002 EUROPISCHE NORM CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische
9、Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50216-2:2002+A1:2002 E ICS 29.120.70; 29.180 English version Power transformer and reactor fittings Part 2: Ga
10、s and oil actuated relay for liquid immersed transformers and reactors with conservator (includes amendment A1:2002) Accessoires pour transformateurs de puissance et bobines dinductance Partie 2: Relais de protection (dgagement gazeux, niveau dhuile) pour transformateurs et ractance immergs dans un
11、dilectrique liquide quips dun conservateur (inclut lamendement A1:2002) Zubehr fr Transformatoren und Drosselspulen Teil 2: Buchholzrelais fr flssigkeitsgefllte Transformatoren und Drosselspulen mit Ausdehnungsgef (enthlt nderung A1:2002) This amendment A1 modifies the European Standard EN 50216-2:2
12、002; it was approved by CENELEC on 2002-11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references conc
13、erning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into
14、 its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Ne
15、therlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. EN 50216-2:2002 2 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN
16、50216-2 on 2001-09-25. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2002-10-01 - latest date by which the national standards conflicting with the EN have to be withdrawn
17、(dow) 2004-10-01 EN 50216-2 is to be read in conjunction with EN 50216-1. Foreword to amendment A1 This amendment was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment
18、 A1 to EN 50216-2:2002 on 2002-11-01. The following dates were fixed: - latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-11-01 - latest date by which the national standards conflicting with the am
19、endment have to be withdrawn (dow) 2005-11-01 3 EN 50216-2:2002 Contents Page 1 Scope. 4 2 Normative references 4 3 Service conditions 4 3.1 Maximum inclination4 3.2 Operating pressure4 3.3 Sensitivity of the relay contacts to magnetic fields . 5 3.4 Special mechanical conditions. 5 4 Dimensions 5 5
20、 Operational performance7 5.1 Alarm and trip contacts 7 5.2 Oil loss from tank. 8 5.3 Latching of trip element . 8 6 Electrical characteristics of switch 8 6.1 Switch type 8 6.2 Rated currents. 8 6.3 Breaking and making capacity. 8 7 Mechanical requirements.9 7.1 Terminal box 9 7.2 Testing facility
21、9 7.3 Gas sampling. 9 7.4 Draining device 9 7.5 Presence of gas in the relay 9 7.6 Mounting arrangement. 9 7.7 Pressure and vacuum 9 8 Nameplate 10 9 Tests. 10 9.1 Routine tests 10 9.2 Type tests 10 EN 50216-2:2002 4 1 Scope EN 50216-2 covers the gas and oil actuated relay (Buchholz relay) for liqui
22、d immersed power transformers and reactors with conservator for indoor or outdoor installation. The device is intended to detect gas release from the unit to be protected, oil surge from the tank to the conservator, complete loss of oil in the conservator. This part of EN 50216 defines the operating
23、 limits, dimensions, operational performance, electrical characteristics, dynamic characteristics. It applies to relays with dry contacts. It is not applicable to flameproof relays. Should environmental conditions and dynamic stress requirements differ from those detailed in clause 3 of EN 50216-1,
24、EN 50216-2 may then be applied by agreement between purchaser and supplier for those parts which are not affected by such abnormal installation conditions. NOTE EN 50216-2 may be used as far as applicable for relays with mercury switches. Restrictions on the use of mercury devices may be imposed by
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN5021622002ENPOWERTRANSFORMERANDREACTORFITTINGSPART2GASANDOILACTUATEDRELAYFORLIQUIDIMMERSEDTRANSFORMERSANDREACTORSWITHCONSERVATORINCORPORATESAMENDMENTAPDF

链接地址:http://www.mydoc123.com/p-716816.html