EN 14506-2005 en Devices to prevent pollution by backflow of potable water - Automatic diverter - Family H type C《防饮用水回流污染的装置 自动排水道 C型H系列》.pdf
《EN 14506-2005 en Devices to prevent pollution by backflow of potable water - Automatic diverter - Family H type C《防饮用水回流污染的装置 自动排水道 C型H系列》.pdf》由会员分享,可在线阅读,更多相关《EN 14506-2005 en Devices to prevent pollution by backflow of potable water - Automatic diverter - Family H type C《防饮用水回流污染的装置 自动排水道 C型H系列》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 14506:2005ICS 13.060.20NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDDevices to prevent pollution by backflow of potable water Automatic diverter Family H, type C.Incorporating Corrigendum October 2009This British Standard was published under the authori
2、ty of the Standards Policy and Strategy Committee on 31 March 2009 BSI 2009ISBN 978 0 580 69362 5Amendments/corrigenda issued since publicationDate CommentsBS EN 14506:2005National forewordThis British Standard is the UK implementation of EN 14506:2005. The UK participation in its preparation was en
3、trusted to TechnicalCommittee B/504/4, Backflow Prevention.A list of organizations represented on this committee can be obtained onrequest to its secretary.The UK technical committee B/504 would like to draw attention to the procedure in 10.4.4.2 in which a low pressure is applied to the device whil
4、st in flow to bath mode. In the opinion of the committee this is unlikely to demonstrate the ability of the device to remain leak tight at the shower outlet when a high bath flow is drawn. Therefore, the committee is of the opinion that instead of a pressure being applied, a flow rate of 0,75 would
5、be a more effective method of testing.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunityfrom legal obligations.31 October 2009 Correction to national fore
6、wordBS EN 14506:2005EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14506May 2005ICS 13.060.20; 23.060.01English versionDevices to prevent pollution by backflow of potable water -Automatic diverter - Family H, type CDispositifs de protection contre la pollution de leau potablepar retour - Inverseu
7、r retour automatique - Famille H, typeCSicherungseinrichtungen zum Schutz des Trinkwassersgegen Verschmutzung durch Rckflieen - AutomatischerUmsteller - Familie H, Typ CThis European Standard was approved by CEN on 24 December 2004.CEN members are bound to comply with the CEN/CENELEC Internal Regula
8、tions which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This Europe
9、an Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national
10、standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN CO
11、MMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14506:2005: EEN 14506:2005 (E) 2 Conte
12、nts Page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Nominal size and pressure ranges 6 5 Designation 7 6 Marking and technical documents.7 7 Symbolization.8 8 General design characteristics 9 9 Physico-chemical characteristics9 10 Characteristics and te
13、sts 10 11 Acoustic characteristics .21 Annex A (normative) Sampling and test sequence22 BS EN 14506:2005EN 14506:2005 (E) 3 Foreword This document (EN 14506:2005) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by AFNOR. This European Standard sha
14、ll be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2005, and conflicting national standards shall be withdrawn at the latest by November 2005. This document has been developed with reference to EN 1717 “Protection ag
15、ainst pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow“. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Be
16、lgium, Cyprus, Czech Republic, Den-mark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxem-bourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. BS EN 14506:2005EN 14506:2005 (E) 4 I
17、ntroduction In respect of potential adverse effects on the quality of water intended for human consumption, caused by the product covered by this document: a) this document provides no information as to whether the product may be used without restriction in any of the Member States of the EU or EFTA
18、; b) it should be noted that, while awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of this product remain in force. BS EN 14506:2005EN 14506:2005 (E) 5 1 Scope This document specifies: a) field of application; b) req
19、uirements for automatic diverters; c) dimensional and the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of automatic diverters; d) test method and requirements for verifying these properties. For sanitary tapware (see Clause 2) with in-tegrated d
20、evices, the automatic diverter is only considered to be a backflow protection device if it has passed the requirements of this document and additionally those of the applicable product standard for the draw off tap or mixing valve; e) marking and presentation; f) acoustics. This document specifies t
21、he characteristics of automatic diverters suitable for use in drinking water systems at pressures up to 1 MPa (10 bar) and temperatures up to 65 C and for 1 h at 90 C. They are intended only for installation with no downstream closing device. This document is applicable to the product type indicated
22、 as follows: i) integrated in spout (outlet); ii) integrated in the mixing body; iii) non-integrated (part of a set) above the maximum water level. This document is not applicable to the product type non-integrated below the maximum water level. 2 Normative references The following referenced docume
23、nts are indispensable for the application of this document. For dated refer-ences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 200, Sanitary tapware Single taps and combination taps (PN 10) - General tec
24、hnical specification EN 248, Sanitary tapware General specification for electrodeposited coatings of Ni-Cr EN 806-1:2000, Specifications for installations inside buildings conveying water for human consumption Part 1: General EN 817, Sanitary tapware Mechanical mixers (PN 10) General technical speci
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN145062005ENDEVICESTOPREVENTPOLLUTIONBYBACKFLOWOFPOTABLEWATERAUTOMATICDIVERTERFAMILYHTYPEC 饮用水 回流 污染

链接地址:http://www.mydoc123.com/p-714225.html