EN 54-28-2016 en Fire detection and fire alarm system - Part 28 Non-resettable line-type heat detectors《火灾探测和火灾报警系统 第28部分 不可重置线型热探测器》.pdf
《EN 54-28-2016 en Fire detection and fire alarm system - Part 28 Non-resettable line-type heat detectors《火灾探测和火灾报警系统 第28部分 不可重置线型热探测器》.pdf》由会员分享,可在线阅读,更多相关《EN 54-28-2016 en Fire detection and fire alarm system - Part 28 Non-resettable line-type heat detectors《火灾探测和火灾报警系统 第28部分 不可重置线型热探测器》.pdf(72页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 54-28:2016Fire detection and fire alarmsystemPart 28: Non-r e s e t t a b l e l i n e - t y p e h e a tdetectorsBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 54-28:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of E
2、N 54-28:2016.The UK participation in its preparation was entrusted to TechnicalCommittee FSH/12/2, Fire detectors.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. U
3、sers are responsible for its correctapplication. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 84512 3ICS 13.220.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of
4、 theStandards Policy and Strategy Committee on 30 June 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 54-28:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 54-28 February 2016 ICS 13.220.20 English Version Fire detection and fire alarm system - Part 28:
5、 Non-resettable line-type heat detectors Systmes de dtection et dalarme incendie - Partie 28 : Dtecteurs de chaleur de type linaire non renclenchables Brandmeldeanlagen - Teil 28: Nicht-rcksetzbare linienfrmige Wrmemelder This European Standard was approved by CEN on 13 December 2015. CEN members ar
6、e bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to
7、the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Ce
8、ntre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithua
9、nia, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-10
10、00 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 54-28:2016 EBS EN 54-28:2016EN 54-28:2016 (E) 2 Contents Page European foreword . 4 Introduction 6 1 Scope 7 2 Normative references 7 3 Terms, definitions and abbrevi
11、ations . 8 3.1 Terms and definitions . 8 3.2 Abbreviations . 9 4 Product characteristics . 9 4.1 General 9 4.2 Nominal activation conditions/sensitivity 9 4.3 Operational reliability 10 4.4 Tolerance to supply voltage . 12 4.5 Performance parameters under fire condition . 12 4.6 Durability of Perfor
12、mance parameters under fire condition 12 5 Testing, assessment and sampling methods 14 5.1 General . 14 5.2 Test procedures nominal activation conditions/sensitivity 18 5.3 Test procedures operational reliability. 18 5.4 Tolerance to supply parameters 20 5.5 Performance parameters under fire conditi
13、on . 20 5.6 Durability of performance parameters under fire condition 21 6 Assessment and Verification of Constancy of Performance (AVCP) 38 6.1 General . 38 6.2 Type testing 38 6.3 Factory Production Control (FPC) 40 7 Classification and designation . 45 8 Marking, labelling and packaging 45 8.1 Ma
14、rking, labelling 45 8.2 Packaging 46 Annex A (normative) Mounting of the sensing element of NLTHD in the heat tunnel . 47 A.1 General . 47 A.2 Mounting arrangement of sensing element 47 Annex B (normative) Heat tunnel for response temperature measurements 49 B.1 General . 49 B.2 Description of the h
15、eat tunnel . 49 Annex C (informative) Construction of the heat tunnel 50 C.1 General . 50 C.2 Heat tunnel construction . 50 Annex D (normative) Test arrangement for vibration tests for sensing element . 52 BS EN 54-28:2016EN 54-28:2016 (E) 3 D.1 General . 52 D.2 Test setup 52 Annex E (normative) Tes
16、t apparatus for impact test on the sensing element 53 E.1 General . 53 E.2 Test apparatus . 53 E.3 Test setup 53 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation . 56 Bibliography . 67 BS EN 54-28:2016EN 54-28:2016 (E) 4 Eu
17、ropean foreword This document (EN 54-28:2016) has been prepared by Technical Committee CEN/TC 72 “Fire detection and fire alarm systems”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by
18、 endorsement, at the latest by August 2016, and conflicting national standards shall be withdrawn at the latest by February 2020. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for
19、 identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports the basic requirements of Regulation (EU) 305/2011. For relationship with EU Regulations, see informative Annex ZA
20、 which is an integral part of this document. EN 54, Fire detection and fire alarm systems consists of the following parts: Part 1: Introduction Part 2: Control and indicating equipment Part 3: Fire alarm devices Sounders Part 4: Power supply equipment Part 5: Heat detectors Point detectors Part 7: S
21、moke detectors Point detectors using scattered light, transmitted light or ionization Part 10: Flame detectors Point detectors Part 11: Manual call points Part 12: Smoke detectors Line detectors using an optical beam Part 13: Compatibility assessment of system components Part 14: Guidelines for plan
22、ning, design, installation, commissioning, use and maintenance Part 15: Point detectors using a combination of detected phenomena Part 16: Voice alarm control and indicating equipment Part 17: Short-circuit isolators Part 18: Input/output devices Part 20: Aspirating smoke detectors BS EN 54-28:2016E
23、N 54-28:2016 (E) 5 Part 21: Alarm transmission and fault warning routing equipment Part 22: Resettable line-type heat detectors Part 23: Fire alarm devices Visual alarm devices Part 24: Components of voice alarm systems Loudspeakers Part 25: Components using radio links Part 26: Carbon monoxide dete
24、ctors Point detectors Part 27: Duct smoke detectors Part 28: Non-resettable line-type heat detectors Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors Part 30: Multi-sensor fire detectors - Point detectors using a combination of carbon monoxide and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN54282016ENFIREDETECTIONANDFIREALARMSYSTEMPART28NONRESETTABLELINETYPEHEATDETECTORS 火灾 探测 报警 系统 28 部分

链接地址:http://www.mydoc123.com/p-712358.html