《EN 1822-5-2009 en High efficiency air filters (EPA HEPA and ULPA) - Part 5 Determining the efficiency of filter elements《高效空气过滤器(HEPA和ULPA) 第5部分 过滤元件效率测定》.pdf》由会员分享,可在线阅读,更多相关《EN 1822-5-2009 en High efficiency air filters (EPA HEPA and ULPA) - Part 5 Determining the efficiency of filter elements《高效空气过滤器(HEPA和ULPA) 第5部分 过滤元件效率测定》.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN1822-5:2009ICS 13.040.40; 23.120NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDHigh efficiency airfilters (EPA, HEPA andULPA)Part 5: Determining the efficiency offilter elementsThis British Standard was published under the authority of the Standards Policy
2、 and Strategy Committee on 31 January 2010 BSI 2010ISBN 978 0 580 61794 2Amendments/corrigenda issued since publicationDate CommentsBS EN 1822-5:2009National forewordThis British Standard is the UK implementation of EN 1822-5:2009. It supersedes BS EN 1822-5:2000 which is withdrawn.The UK participat
3、ion in its preparation was entrusted to Technical Committee MCE/21/3, Air filters other than for air supply for I.C. engines and compressors.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessar
4、y provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 1822-5:2009EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1822-5 November 2009 ICS 13.040.40 Supersedes EN 1822-5:2000English Ver
5、sion High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements Filtres air haute efficacit (EPA, HEPA et ULPA) - Partie 5: Mesure de lefficacit de llment filtrant Schwebstofffilter (EPA, HEPA und ULPA) - Teil 5: Abscheidegradprfung des Filterelements Th
6、is European Standard was approved by CEN on 17 October 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical refer
7、ences concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member
8、into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lat
9、via, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Bruss
10、els 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1822-5:2009: EBS EN 1822-5:2009EN 1822-5:2009 (E) 2 Contents Page Foreword 4Introduction 51 Scope .62 Normative references .63 Terms and definitions 64 Description of the met
11、hod .74.1 General 74.2 Measurement method using fixed sampling probe 84.3 Scan method .84.4 Statistical efficiency test method for EPA filters (Group E) .85 Test filter 96 Test apparatus 96.1 General 96.2 Test duct 96.2.1 Test air conditioning 96.2.2 Adjustment of the volume flow rate 96.2.3 Measure
12、ment of the volume flow rate 96.2.4 Aerosol mixing section 96.2.5 Test filter mounting assembly .96.2.6 Measuring points for the pressure drop . 106.2.7 Sampling . 106.3 Aerosol generation and measuring instruments . 116.3.1 General . 116.3.2 Apparatus for testing with a monodisperse test aerosol 11
13、6.3.3 Apparatus for testing with a polydisperse test aerosol 127 Conditions of the test air 178 Test procedure . 178.1 Preparatory checks . 178.2 Starting up the aerosol generator 178.3 Preparation of the test filter 178.3.1 Installation of the test filter . 178.3.2 Flushing the test filter . 178.4
14、Testing 188.4.1 Measuring the pressure drop . 188.4.2 Testing with a monodisperse test aerosol 188.4.3 Testing with a polydisperse test aerosol 189 Evaluation . 1810 Test report 2011 Maintenance and inspection of the test apparatus 22Annex A (informative) Testing and classification method for filter
15、s with MPPS 0,1 m (e.g. membrane medium filters) 23A.1 Background 23A.2 MPPS of filters with Membrane filter medium 23A.3 Penetration consistency and uniformity of Membrane filter medium 23BS EN 1822-5:2009EN 1822-5:2009 (E) 3 A.4 Procedure for testing and classification of filters with Membrane fil
16、ter media . 23A.4.1 Integral Penetration 23A.4.2 Classification 24A.4.3 Local Penetration . 24A.5 Publication of data and labelling of products with membrane filter media . 24Annex B (normative) Testing and classification of filters using media with (charged) synthetic fibers . 26B.1 Background . 26
17、B.2 Scope . 26B.3 Procedure for testing and classification of HEPA and ULPA filters using media with (charged) synthetic fibres . 26B.4 Publication of data and labelling of products for HEPA and ULPA filters using media with (charged) synthetic fibres . 27Bibliography . 28BS EN 1822-5:2009EN 1822-5:
18、2009 (E) 4 Foreword This document (EN 1822-5:2009) has been prepared by Technical Committee CEN/TC 195 “Air filters for general air cleaning”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text
19、or by endorsement, at the latest by May 2010, and conflicting national standards shall be withdrawn at the latest by May 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for id
20、entifying any or all such patent rights. This document supersedes EN 1822-5:2000. It contains requirements, fundamental principles of testing and the marking for efficient particulate air filters (EPA), high efficiency particulate air filters (HEPA) and ultra low penetration air filters (ULPA). EN 1
21、822, High efficiency air filters (EPA, HEPA and ULPA), consists of the following parts: Part 1: Classification, performance testing, marking Part 2: Aerosol production, measuring equipment, particle counting statistics Part 3: Testing flat sheet filter media Part 4: Determining leakage of filter ele
22、ment (scan method) Part 5: Determining the efficiency of filter elements According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Esto
23、nia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 1822-5:2009EN 1822-5:2009 (E) 5 Introduction As decided by CEN/T
24、C 195, this European Standard is based on particle counting methods which actually cover most needs of different applications. The difference between this European Standard and previous national standards lies in the technique used for the determination of the integral efficiency. Instead of mass re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN182252009ENHIGHEFFICIENCYAIRFILTERSEPAHEPAANDULPAPART5DETERMININGTHEEFFICIENCYOFFILTERELEMENTS 高效 空气

链接地址:http://www.mydoc123.com/p-709349.html