《EN 1378-1996 en Foodstuffs - Determination of Aspartame in Table Top Sweetener Preparations - Method by High Performance Liquid Chromatography《食品 块状甜品中糖精的测定 高效液体色谱分析法》.pdf》由会员分享,可在线阅读,更多相关《EN 1378-1996 en Foodstuffs - Determination of Aspartame in Table Top Sweetener Preparations - Method by High Performance Liquid Chromatography《食品 块状甜品中糖精的测定 高效液体色谱分析法》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 STD-BSI BS EN 1378-ENGL 1797 Lh2qbbS 0b332 BRITISH STANDARD Foodstfls - Determination of aspartame in table top sweetener preparations - Method by high performance liquid chromatography The hopean Standard EN 1378 : 1996 has the status of a British Standard ICs 67.180.10 NO COPYING WITHOUT BSI PERM
2、ISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW 383 BS EN 1378 : 1997 BS EN 1378 : 1997 Amd. No. This British Standard, having been prepared under the direction of the Consumer Products and Services Sector Board, was published under the authority of the Standards Board and comes into effect on 15 May 19
3、97 O BSI 1997 Date Text affected Committees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Panel AW/-B, Food analysis - Horizontal methods, upon which the following bodies were represented: Association of Public Analyss Food and Drink Federa
4、tion Mtuk of Food Science and Technology Laboratory of the Government Chemist Muustry of Agriculture, Fisheries and Food Royal Society of Chemistry The following BSI references relate to the work on this standard Committee reference AW/-/3 Draft for comment 94601926 DC ISBN O 680 27122 6 STD=BSI BS
5、EN L378-ENGL 1997 Lb2LibbS Ob33298 15b W BS EN 1378 : 1997 Contents Committees responsible Page Inside front cover National foreword ii Foreword 2 Text of EN 1378 3 * m * O BSI 1997 i STD.BSI BS EN 1378-ENGL 1777 Lb2libb b33277 072 D BS EN 1378 : 1997 National foreword This British Standard has been
6、 prepared by Technical Panel AW/B and is the English ianguage version of EN 1378 : 1996 Foodstufls - DetemL.ination of aspartume in table top sweetenerprepamtions - Method by high pm$onnance liquid chnnnutogmphy, published by the European Committee for Standardization (CEN). EN 1378 was produced as
7、a resuit of international discussions in which the United Kingdom took an active part. Cross-references Publication referred to EN IS0 3696 : 1995 Corresponing British Standard BS EN IS0 3696 : 1995 Water for analyticai labomtow use. Spehficatwn and test methods IS0 5725 : 1986, to which informative
8、 reference is made in the text, has been superseded by IS0 57251 : 1994, IS0 57252 : 1994, IS0 5725-3 : 1994, IS0 57254 : 1994 and IS0 5725-6 : 1994 which are identicai with BS IS0 5725 Acm (trueness und precision) of rn.4msu-t methods and results, BS IS0 57251 : 1994 General principles and definiti
9、ons, Bs IS0 57252 : 1994 Bmic method for ULe detemnination of -peataoil.ity and repmdmibility of a stundud meclsurement method, BS IS0 57253 : 1994 Inte?naediate measures of the precision of a standavd rrtmsurement method, BS IS0 57254 : 1994 Basic method for LD is the loss in mass on drying, in per
10、cent 6 Apparatus and equipment Usual laboratory apparatus and, in particular, the following. 6.1 Filtration unit, e.g. glass vacum lWon unit consisting of a giasS sintered disk (diameter 50 mm), a 250 mi top section and a 1 1 conical flask, ail with ground glass joints. 6.2 Membrane fzlter, suitable
11、 for the mobile phase (4.Q pore size 5 5 pn. c is the substance concentration. O BSI 1997 STD.BSI BS EN 1378-ENGL 1797 LbZIbb9 Ob33303 31i3 Page 4 EN 1378 : 1996 6.3 High pqlnmum liguid chwmatograph consisting of a pump, a sample appiicahr, a UV detedor with variable wavelength setting and an evalua
12、tion system e.g. a chart recorder or integrator. 6.4 Analytical reversed phclse separating column, e.g. C 18 reversed phase, particle size 10 pm, diameter 4 mm, length 250 mm. other particle sizes than specified in this standard may be used. Separation parameters have to be adapted to such materiais
13、 to guarantee equivalent results. NOTE. Minimal theoretical piates at the retention volume of the resolved analyte should preferably be not less than 1900 under the conditions of chromatography employed. 6 Procedure 6.1 Determination of the average tablet mass Determine the mass of at least 20 sweet
14、ener tablets to the nearest 0,l mg and calculate the average mass of one tablet. NOTE. For improved accuracy the use of 100 tablets is recommended. 6.2 Determination of loss in mass on drying of standard substance Weigh, to the nearest 0,l mg, about 1,0 g of the remaining nely ground aspartame stana
15、rd substance (4.1). Dry this portion to constant mass at (105 f 2) “C and determine the loss in mass on drying (LD) in per cent by weighing. 6.3 Preparation of the sample test solution Dissolve an amount of nely ground (mo) table top sweetener prepamlion ment to about 400 mg aspartame (corresponduig
16、 to 20 times the average mass of a tablet), and after tsansferring it to a 200 ml volumetric flask, dissolve in water and dilute to the mark mute 20,O mi of this solution with the mobile phase (4.6) to 200,O mi (VI) and lter through a membrane lter. Prepare the sample test solution on the day of the
17、 analysis. 6.4 Identification by HPLC Identify the sweetener to be determined either by comparing the retention thne in the sample with that of the standard substance, or by comparing the absorption properties of the sample with those of the standard substance after either recording the absorption c
18、urve or talnng measurements at different wavelengths in the relevant wavelength range for both sample and standard NOTE 1. if the separating column (6.4) and the mobile phase (4.6) are used, it has been found satisfactory to adopt the following experimental conditions (see figure A. 1). Flow 1,5 mlm
19、in UV detection 217 nm Volume iIyected 20 pl NOTE 2. When detecting at 210 nm, a higher sensitivity can be achieved. Possible interferences with decomposition products from aspartame such as diketopiperazine or phenylalanine can OcCui: 6.6 Determination by HPLC lb carry out the determination by the
20、external standard method, integrate the peak areas or determine the peak heights and compare the results with the corresponding value for the standard substance or use a dibraon graph. Inject equal volumes of the sample and standard test solutions. NOTE. The chromatogram shown in figure Al in was pr
21、epared using a C 18 reversed phase, particle size 10 pm, diameter 4,O mm, length 250 nun column. 7 Expression of results 7.1 Graphical evaluation (optional) Plot the absorption values of the aspartsune standard solutions (4.6) on millimetre graph paper against the aspartame concentrations in mihgram
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN13781996ENFOODSTUFFSDETERMINATIONOFASPARTAMEINTABLETOPSWEETENERPREPARATIONSMETHODBYHIGHPERFORMANCELIQUIDCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-708303.html