EN 13200-3-2005 en Spectator facilities - Part 3 Separating elements - Requirements《观众设施 第3部分 分隔单元 要求》.pdf
《EN 13200-3-2005 en Spectator facilities - Part 3 Separating elements - Requirements《观众设施 第3部分 分隔单元 要求》.pdf》由会员分享,可在线阅读,更多相关《EN 13200-3-2005 en Spectator facilities - Part 3 Separating elements - Requirements《观众设施 第3部分 分隔单元 要求》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 13200-3:2005Spectator facilities Part 3: Separating elements RequirementsThe European Standard EN 13200-3:2005 has the status of a British StandardICS 91.040.10; 97.200.10; 97.220.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g
2、3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 13200-3:2005This British Standard was published under the authority of the Standards Policy and Strategy Committee on 26 January 2006 BSI 26 January 2006ISBN 0 580 47617 0National forewordTh
3、is British Standard is the official English language version of EN 13200-3:2005.The UK participation in its preparation was entrusted to Technical Committee B/552, Spectator facilities, which has the responsibility to: A list of organizations represented on this committee can be obtained on request
4、to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electro
5、nic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to unde
6、rstand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a f
7、ront cover, an inside front cover, the EN title page, pages 2 to 19 and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 13200-3Novem
8、ber 2005ICS 91.040.10; 97.200.10; 97.220.10English VersionSpectator facilities - Part 3: Separating elements - RequirementsInstallations pour spectateurs - Partie 3: Elments desparation - ExigencesZuschaueranlagen - Teil 3: Abschrankungen -AnforderungenThis European Standard was approved by CEN on 7
9、 October 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be o
10、btained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Sec
11、retariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Port
12、ugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reservedwor
13、ldwide for CEN national Members.Ref. No. EN 13200-3:2005: EEN 13200-3:2005 (E) 2 Contents Page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .5 4 General requirements6 4.1 Preliminary considerations.6 4.2 Barrier design and loading .7 4.3 Design procedures 7 4.
14、4 Barrier heights .7 4.5 Deflection8 4.6 Fixings 8 4.7 Safety details8 4.8 Support from adjacent construction8 4.9 Maintenance .8 4.10 Barriers and sightline considerations .8 5 Specific requirements .8 5.1 General8 5.2 External perimeter barriers.9 5.3 Activity area barriers .9 5.4 Segregation elem
15、ents .10 5.5 Crush Barriers11 5.5.1 Main design criteria .11 5.5.2 Crush barriers - factors determining the horizontal imposed load 11 5.6 Barriers in front and behind seating12 5.7 Barriers in spectator galleries12 5.8 Ingress and turnstiles .12 5.8.1 The need to count12 5.8.2 Loads 12 5.9 Exit doo
16、rs and gates .13 5.9.1 Loads 13 5.10 Temporary barriers13 5.11 Front of stage barriers 13 Annex A (normative) Tables and Figures .14 A.1 General notes to Tables A.1, A.2 and A.315 A.2 Notes to Table A.115 A.3 Notes to Table A.216 A.4 Notes to Table A.316 Bibliography 19 EN 13200-3:2005 (E) 3 Forewor
17、d This European Standard (EN 13200-3:2005) has been prepared by Technical Committee CEN/TC 315 “Spectator facilities”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at th
18、e latest by May 2006, and conflicting national standards shall be withdrawn at the latest by May 2006. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Rep
19、ublic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 13200-3:2005 (E) 4 Introduction This European Standard has b
20、een prepared in order to specify the general design criteria for spectator facilities (permanent, movable, demountable and telescopic), with the purpose of enabling their functionality. Within this European Standard minimum and recommended values for dimensions and loadings are occasionally presente
21、d. It should be recognised that these values are to be considered as values that in part recognise different national requirements as a basic provision. Attention is drawn to the fact that in certain countries additional/different requirements may be applicable due to existing national regulations o
22、r equivalent. This European Standard is divided among six parts: EN 13200-1, Spectator facilities - Part 1: Layout criteria for spectator viewing area - Specification prCEN/TR 13200-2, Spectator facilities - Layout criteria of service area Part 2: Characteristics and national situations EN 13200-3,
23、Spectator facilities - Part 3: Separating elements - Requirements prEN 13200-4 Spectator facilities - Part 4: Seats - product characteristics prEN 13200-5 Spectator facilities - Part 5: Telescopic stands prEN 13200-6, Spectator facilities Part 6: Demountable (temporary) stands IMPORTANT NOTES NOTE 1
24、 The proposed values for barrier loadings contained in Tables A1, A2 and A3 may be justified from experimentally determined values appropriate to the barrier provision. NOTE 2 Separating elements for demountable and retractable stands are included within this European Standard. NOTE 3 Safety managem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1320032005ENSPECTATORFACILITIESPART3SEPARATINGELEMENTSREQUIREMENTS 观众 设施 部分 分隔 单元 要求 PDF

链接地址:http://www.mydoc123.com/p-707418.html