EN 1298-1996 en Mobile Access and Working Towers - Rules and Guidelines for the Preparation of an Instruction Manual《移动式工作吊盘 指导手册编制规则和指南》.pdf
《EN 1298-1996 en Mobile Access and Working Towers - Rules and Guidelines for the Preparation of an Instruction Manual《移动式工作吊盘 指导手册编制规则和指南》.pdf》由会员分享,可在线阅读,更多相关《EN 1298-1996 en Mobile Access and Working Towers - Rules and Guidelines for the Preparation of an Instruction Manual《移动式工作吊盘 指导手册编制规则和指南》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、CEN ENbL2 b = 3404587 0337427 93T BRITISH STANDARD Mobile access and working towers - Rules and guidelines for the preparation of an instruction manual BS EN 1298 : 1996 The European Standard EN 1298 : 1996 has the status of a British Standard ICs 91 20 F. /i 81111111 -1 * sr NO COPYING WITHOUT B _
2、CEN EN*3278 96 3404589 0337428 876 W Amd.No. BS EN 1298 : 1996 Date Text affected Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee B/514, Access and support equipment, to Subcommittee B/514/24, Access towers, upon which th
3、e following bodies were represented Construction Industry liraining Board Electrical Conh-actors Association Health and Safety Executive Hire Association of Europe Prefabricated Aluminium Scaffolding Manufacturers Association Co-opted members This British Standard, having been prepared under the dir
4、ection of the Sector Board for Building and Civil Engineering, was published under the authority of the Standards Board and comes into effect on 15 September 1996 O BSI 1996 The following BSI references relate to the work on this standard Committee reference B/514/24 DI- d) the specification of the
5、maximum wind limits: - when working on the mobile access tower is permissible; - when the freestanding mobile access tower shall be dismantled or made secure. Page 3 EN 1298 : 1996 5 Identification The instruction manual shall give information about the total structure of the mobile access tower and
6、 the individual components needed to erect the total stnxcture. NOTE. It is recommended that this information is given with clear references from individual components to the total structure, such as exploded drawings. 6 Erection and dismantling 6.1 The instruction manual shall specify the following
7、 information: a) the number of people required for erection and dismantling; b) the listing of pasts, their weights and the quantities of these parts needed for erection and dismanting of the mobile access tower to a specified height. 6.2 The instruction manual shall specify the following subjects t
8、o be checked before erecting the mobile access tower. 6.2.1 The location of the mobile access tower shall be checked to prevent hazards during erection, dismantling, moving and safe working with respect to: a) ground conditions; b) level and slope; c) obstructions; d) wind conditions. 6.2.2 It shall
9、 be checked that all parts, aiualiary tools and safety equipment (ropes, etc.) for erecting the mobile access tower are available on site. 6.3 The instruction manual shall specify the following information for erecting the mobile access tower: a) procedure for erecting the mobile access tower, descr
10、ibing the correct sequence of actions. This description shall include illustrations and, if nec-, added text to these pictures; b) method for vertical alignment of the mobile access tower within an inclination of 1 “m; c) detailed information about the way connections shall be attached and disconnec
11、ted d) description of the use and fhg of stabilizers, outriggers andor ballast; e) description of the recommended method of lifting the components for erecting the upper sections; f) the correct location of connections for braces, outriggers or stabilizers and ballast shall be clearly shown; g) desc
12、ription of the use and furing of stair or ladder access; h) description of the use and furing of guardrails and toeboards; i) procedure for dismantling the mobile access tower (if applicable with reference to the erection procedure); j) the following warning: Damaged or incorrect components shall no
13、t be used. O BSI 1996 Page 4 EN 1298: 1996 7 Stability The instruction manual shall include: a) guidelines to determine the wind conditions as given in national regulations and actions to be taken if the wind conditions exceed the values as specified in clause 4; b) instructions for the use of stabi
14、lizers, outriggers andor ballast for all conditions for which the mobile access tower is intended; c) warning about horizontal and vertical loads which contribute to overturning of the mobile access tower, such as: - horizontal loads caused by use; for example, as a result of work on an adjacent str
15、ucture; - additional wind loads (tunneiliig effect of open-ended buildings, uncladded buildings and on building corners). d) recommendations for tying in mobile access towers when left unattended; e) the instruction manual shall include the following Stabilizers or outriggers and ballast shall alway
16、s be fitted when specified. warning: 8 Use 8.1 The instruction manual shall give the following checkpoints before each use of the mobile access tower, in addition to the checks made during the erection procedure: a) that the mobile access tower is vertical or needs reaustment; b) whether the structu
17、re assembly is still correct and complete; c) that no environmental changes influence safe use of the mobile access tower. 8.2 The instruction manual shail give guidelines for the safe use of the mobile access tower, also with respect to the national or local regulations. 8.3 The instniction manual
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN12981996ENMOBILEACCESSANDWORKINGTOWERSRULESANDGUIDELINESFORTHEPREPARATIONOFANINSTRUCTIONMANUAL 移动式

链接地址:http://www.mydoc123.com/p-707049.html