EN 12690-1999 en Biotechnology - Performance Criteria for Shaft Seals《生物技术 轴密封的性能标准》.pdf
《EN 12690-1999 en Biotechnology - Performance Criteria for Shaft Seals《生物技术 轴密封的性能标准》.pdf》由会员分享,可在线阅读,更多相关《EN 12690-1999 en Biotechnology - Performance Criteria for Shaft Seals《生物技术 轴密封的性能标准》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、STD-BSI BS EN L2bSO-ENGL 1999 lb24bb9 0778934 510 W BRITISH STANDARD Biotechnology - Performance criteria for shaft seals The European Standasd EN 126901999 has the status of a British Standard ICs 07.080; 21.140 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN 12690:1999
2、 STDmBSI BS EN L2b70-ENGL 1777 lb24bb 0778735 457 m been prepared under the direction of the Sector Amd. No. Date Committee for Materiais and Chemicals, was published under the authority of the Standards Committee and cornes into effect on 15 June 1999 O BSI 06-1999 ISBN O 580 32270 X BS EN 126W1999
3、 Comments National foreword This British Standard is the English language version of EN 12690 1999. The UK participation in its preparation was entrusted to Technical Coinniittee CW58, Biotechnology, which has the responsibility to: - aid enquirers to understand the text; - present to the responsibl
4、e European committee any enquiries on the - monitor related international and European developments and promulgate interpretation, or proposals for change, and keep the UK interests informed; them in the UK. A list of organizations represented on this committee can be obtairied on request to its sec
5、retary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standar
6、ds Electronic Catalogue. A British Standard does not purport to include aU the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages
7、This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 7 and a back cover. STD.BS1 BS EN 12b90-ENGL L777 m lb2Libb7 077873h 373 m EUROPEAN STANDARD NORME EUR0PEE”E EUROPAISCHE NORIM EN 12690 February 1999 ICs 07.080 07.100.01 Descriptors: biotechnoloa, environmen
8、tal protection, accident prevention, work safes, hazards, contamination, microorganisms, noxious microorganisms, inspection, leaktightness, laboratory equipment, sterilization, marking, technical notices. English version Biotechnology - Perforrnance criteria for shaft se - release of microorganisms
9、after operation due to insufficient inactivation and/or removal of microorganisms when the equipment is opened or dismantled. NOTE Common causes of malfunctioning are age, loss of barrier fluid in double seals, rough shaft, incorrect fitting, incorrect specification, incorrect maintenance. 5 Perform
10、ance classes 5.1 General The shaft seal shall be classified for the following performance criteria with regard to the contained use of microorganisms: - 1eakLightness; - cleanability; - sterilizability. The performance of the shaft seal shali be determined separately for each of these criteria in ac
11、cordance with hbles 1, 2 and 3. NOTE A shaft seal can for example be in class SI-A for sterilizability, but in class LI-C for leaktightness. O BSI 061999 STD-BSI BS EN LZbSO-ENGL 1999 I Lb2LibbS 07789i.10 8/11 m Performance class for sterilizability Sterilizabilitx Index (SI) 6.2 Leaktightness The p
12、erformance classes for leaktightness of the shaft seal are given in Table 1. Table 1 - Leaktightness performance leaktightness class Leaktightness Index (LI) leakage of target microorganism not defined Description of performance class LI-B leakage) of target microorganism detected and quantified und
13、er defined conditions leakage11 of target microorganism tested under defined conditions and leakage below detection limit or Based on leakage assessment by BATNEEC (Best Available Techniques Not Entailing Excessive Costs)“ 2, Prescribed threshold value should be based on the required safety level an
14、d can for example be the detection limit of an approved BATNEEC. 6.3 Cleanability The performance classes for cleanability of the shaft seal are given in Table 2. Table 2 - Cleanabilitv Derformance Performance class for Description of performance cleanability I class Cleanability Indix (CI) I CI-A I
15、 visible soil or cleanliness I not defined I CI-B cleanabilityl) tested and quantified under defined conditions or designed with regard to specified I technical criteria CI-C I cleanabilityl) tested under defined conditions and soil below detection limit or threshold value 2, Based on assessment by
16、BATNEEC (Best Available Techniques Not Entailing Excessive Costs)* 2, Prescribed threshold value should be based on the required safety level and can for example be the detection limit of an approved BATNEEC. NOTE Cleanability applies as a performance criterion for the shaft seal where: - deposits o
17、f soil at or in the shaft seal could jeopardize the sterilization procedure if the sterilization media do not reach all parts of the shaft seal or if the required temperature is not reached; - cleaning procedures are intended to remove and inactivate microorganisms to make the shaft seal safe for ha
18、ndling without using any other sterilization or inactivation procedure. Page 5 EN 12690:1999 6.4 Sterilizability The performance classes for sterilizability of the shaft seal are given in Wle 3. Table 3 - Sterilizability performance SI-A SI-B shaft seal not suiable or not tested for reduction of via
19、ble target microorganisms shaft seal can be treated for a specified reduction of viable target microoramisms SI-C I shaft seal can be sterilized NOTE In this table the result (performance) of an inactivation procedure is described and not the way or means of achieving the result. 6.6 Use of performa
20、nce classes in equipment selection The selection of the appropriate class for performance of a shaft seal in a biotechnological process shall be made in accordance with the risk analysis as described in EN 12460. NOTE In practice the following has been found to be suitable for guidance for the usage
21、 of classes given in Tables 1, 2 and 3. if the release of microorganisms is to be minimized, a shaft seal can be used which is classified SI-B, CI-A and LI-B or better. If the release of microorganisms is to be prevented, a shaft seal can be used which is classified SI-C, CI-B and LI-C or better. if
22、 these performance classes are not used as described or are considered to be inappropriate, alternative andor additional measures are necessary e.g. procedural measures, secondary containment or disposable equipment. 6 Classieation and verincation of performance 6.1 General Shafts seals covered by t
23、his European Standard shd be classified in accordance with Tables 1,2 and 3. The performance of shaft seals is determined and verified by the manufacturer or by the user. NOTE 1 Under certain circumstances the user might reclassify the shaft seal. If for example the shaft seal could comply with ster
24、ilizability class SI-C but is classified SI-B because the manufacturer has done only a simple test, the user can reclassify the shaft seal to SI-C if he executes and documents the appropriate tests. * Use of BATNEEC does not mean that financial issues moderate the degree of safety. Where several met
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN126901999ENBIOTECHNOLOGYPERFORMANCECRITERIAFORSHAFTSEALS 生物技术 密封 性能 标准 PDF

链接地址:http://www.mydoc123.com/p-706634.html