EN 12424-2000 en Industrial Commercial and Garage Doors and Gates - Resistance to Wind Load - Classification《商业和车库门 对风负载的抗性 分级》.pdf
《EN 12424-2000 en Industrial Commercial and Garage Doors and Gates - Resistance to Wind Load - Classification《商业和车库门 对风负载的抗性 分级》.pdf》由会员分享,可在线阅读,更多相关《EN 12424-2000 en Industrial Commercial and Garage Doors and Gates - Resistance to Wind Load - Classification《商业和车库门 对风负载的抗性 分级》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 STD-BSI BS EN L2424-ENGL 2000 lb2Libb7 0875222 bOT BRITISH STANDARD Industrial, commercial and garage doors and gates - Resistance to wind load - Classification The European Standard EN 124242000 has the status of a British Standard ICs 91.060.60 BS EN 12424:ZOOO NO COPYING WITHOUT BSI PERMISSION E
2、XCEPT AS PEEMITiED BY COPYRIGET LAW National foreword direction of the Sector Amd.No. Committee for Bidding and Civil Engineering, was published under the authority of the Standards Committee and comes into effed on 15 October 2000 O BSI 10-2000 This British Standard is the official English language
3、 version of EN 124242000. The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/5, Industrial, commercial and garage doors and gates, which has the responsibility to: Date Comments - aid enqui
4、rers to understand the text; - present to the responsible European committee any enquines on the - monitor related international and European developments and promulgate interpretation, or proposals for change, and keep the UK interests informed; them in the UK A list of organizations represented on
5、 this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence In
6、dex”, or by using the “Fnd” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself c
7、onfer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 5 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. ISBN O 580 36539 5 STD-BSI BS EN LZ
8、q24-ENGL 2000 Lb24bb7 0875224 482 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12424 July 2000 ICs 91.060.50 English version Industrial, commercial and garage doors and gates - Resistance to wind load - Classification Portes quipant les locaux industriels, commerciaux et les garages - Rsista
9、nce la charge de vent - Classification Tore - Widerstand gegen Windlast - Klassifizierung This European Standard was approved by CEN on 19 July 2000. CEN members are bound to comply with the CENICENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status
10、of a national standard without any alteration. Up-to-date lists and bibliographicat references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A vers
11、ion in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, Fran
12、ce, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT6 EUROPEEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Central Secretariat: rue de Stassart, 36 8-1050 Brussels O 20
13、00 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12424:2000 E STD-BSI BS EN 12929-ENGL 2000 W Lb24bb9 0875225 317 I Page 2 EN 12424:2000 Contents Foreword 1 Scope 2 Normative References 3 Terms and definitions 4 Classification 5
14、Marking Bibliography Page 2 4 5 Foreword This European Standard has been prepared by Technical Committee CENTTC 33 II Doors, windows, shutters, building hardware and curtain walling“, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard,
15、either by publica- tion of an identical text or by endorsement, at the latest by January 2001, and conflicting national standards shall be withdrawn at the latest by January 2001. According to the CENKENELEC Internal Regulations, the national standards organizations of the following countries are bo
16、und to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Lux- embourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United King- dom. No existing EN standard is superseded. This standard is one
17、 of a series of performance standards identified within the product stan- dard prEN 13421:1998. European Standards as well as relevant national regulations and standards will enable the actual exposure levels to be determined for the individual locations of the products. 1 Scope 1.1 General This Eur
18、opean Standard specifies the classification for wind load for doors in a closed posi- tion. The doors are intended for installation in areas in the reach of people, for which the main intended uses are giving safe access for goods, vehicles and persons in industrial, commer- cial or residential prem
19、ises. STD.BS1 BS EN L2YZY-ENGL 2000 PI Lb24bb 087522b 255 m Page 3 EN 12424:2000 The doors may be manually or power operated. NOTE In case of wind load it is not necessary that the door can be opened or closed. This document applies to all doors provided in accordance with prEN 13241 :1998. 1.2 Excl
20、usions It does not apply to: - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors less than 2,5 m wide and 6,25 m2 area, designed principally for pedestrian use; - re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN124242000ENINDUSTRIALCOMMERCIALANDGARAGEDOORSANDGATESRESISTANCETOWINDLOADCLASSIFICATION 商业 车库门 负载 抗性

链接地址:http://www.mydoc123.com/p-706280.html