1、 EIA STANDARD Assembly Component Tray ACT EIA-960-B (Revision of EIA-960-A) April 2017 Electronic Components Industry Association ANSI/EIA-960-B-2017 Approved: April 20, 2017 EIA-960-B NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating mis
2、understandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respec
3、t preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the standard is to be used either dom
4、estically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the S
5、tandard or Publication. This EIA standard is considered to have International Standardization implications, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA standard and the IEC document can be made. This Standard doe
6、s not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (Fro
7、m Standards Proposal No. 5378, formulated under the cognizance of the EIA ACH Committee on Automated Component Handling Standards). Published by ELECTRONIC COMPONENTS INDUSTRY ASSOCIATION 2017 Standards & Technology Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE ! DONT VIOLATE TH
8、E LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: IHS Markit 15 Inverness Way East Englewood, CO 80112-5704 or
9、call USA and Canada (1-877-413-5186), International (303-397-7956) i Contents 1 Scope 1 2 Introduction 1 3 Applicable Documents . 1 4 Requirements . 1 Annex A - Informative Application Notes A-1 Figures Figure 1 - Basic Tray Dimensions 2 Figure 2 - Orientation Proof Tray Feature Locations . 3 Figure
10、 3 - 3D STACK VIEW . 4 Figure 4 - TRAY STACK DETAILS . 4 Figure 5 - STACK LUG DETAIL 5 Figure 6 - PART TRAY CLEARANCE . 5 Figure 7 - “J” TRAY DIMENSIONS . 6 Figure 8 - Maximum lateral component movement . 7 Figure A1 A-1 Figure A1 - Finger Pick Trough A-1 Figure A2a - Gripper Clearance A-1 Figure A2
11、b - Gripper Clearance . A-2 Figure A3 - Location Indicator . A-2 Left Intentionally Blank.EIA-960-B Page 1 ASSEMBLY COMPONENT TRAY ACT 1 Scope This standard covers requirements for Assembly Component Trays ACTs used during automated assembly processes. The standard size is covered which works with t
12、ray slots handling an envelope of 298.45mm (11.75inches) x 254mm (10inches) and the “J” size which works with tray slots handling an envelope of 322.58mm (12.7 inches) x 135.89mm (5.35 inches). 2 Introduction This standard was formulated to provide dimensions and tolerances necessary for trays to lo
13、cate components in matrix positions for existing automated handling equipment. The standard ACT tray will fit within the footprint of two side by side JEDEC-PGA Package trays which measure 322.58mm x 135.89mm (12.7” x 5.35”) each. They can also be used as shipment packages in the logistic chain, whe
14、re the tray box both RSC (Regular Slotted Carton) style and self-locking optimize the space used on a US 48” pallet and the A2N and L9N air cargo containers. Both RSC and self-locking boxes designed around the ACT dimensions maximize parts within the 1728 in3 shipping volume limit without incurring
15、Dimension Weight charges. The “J” ACT tray matches the outside dimensions and general geometry of PGA Package trays. It is designed as a form, fit, and function, alternative to JEDEC-PGA trays. 3 Applicable Documents Unless otherwise specified the following documents form a part of this standard to
16、the extent specified herein: EIA-383 “Preparation for the Delivery of Electrical and Electronic Components” ANSI/ESD S541 “ESD Association Standard for the Protection of Electrostatic Discharge Susceptible Items” EIA-556 “Electronic Industries Association Outer Shipping Container Bar Code Label Stan
17、dard” EIA-583 “Packaging Material Standards for Moisture Sensitive Items” EIA-624 “Product Package Bar Code Label Standard for Non-Retail Applications” 4 Requirements 4.1 Assembly Component Trays (ACTs) must meet the requirements defined in the Figures and Tables presented herein. 4.2 The packaging,
18、 materials and processes shall not adversely affect the mechanical and electrical characteristics or marking of the components. For intermediate and final packaging, refer to EIA-383 “Preparation for the Delivery of Electrical and Electronic Components,” EIA-960-B Page 2 ANSI/ESD S541 “ ESD Associat
19、ion Standard for the Protection of Electrostatic Discharge Susceptible Items,” and EIA-624 “Product Package Bar Code Label Standard for Non-Retail Applications.“ 4.3 Basic Tray Dimensions Standard ACT Tray Metric English Figure 1 Basic Tray Dimensions Notes: 1.) The pocket matrix is to be symmetric
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA960B2017ASSEMBLYCOMPONENTTRAYCACTPDF

链接地址:http://www.mydoc123.com/p-704502.html