ECA EIA-364-54A-1999 TP-54A Magnetic Permeability Test Procedure For Electrical Connectors Contacts and Sockets《TP-54A电子连接器、接触和插座导磁性试验程序》.pdf
《ECA EIA-364-54A-1999 TP-54A Magnetic Permeability Test Procedure For Electrical Connectors Contacts and Sockets《TP-54A电子连接器、接触和插座导磁性试验程序》.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-54A-1999 TP-54A Magnetic Permeability Test Procedure For Electrical Connectors Contacts and Sockets《TP-54A电子连接器、接触和插座导磁性试验程序》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-54A Magnetic Permeability Test Procedure For Electrical Connectors, Contacts, and Sockets EIA-364-54A (Revision of EIA-364-54) May 1999 ELECTRONIC COMPONENTS, ASSEMBLIES Low-Mu: Severn Engineering Co., Permeability Indicator #3904, or equivalent. 3 Test specimen 3.1 Description The
2、test specimen shall consist of a fully assembled connector, connector components or contacts, as specified. EIA-364-54A Page 2 4 Test procedure 4.1 Unless otherwise specified, a 2.0 Mu pellet (insert) shall be used. The magnet of the hand-held indicator shall be alternately applied to and delicately
3、 removed from all the areas of the specimen. 4.2 Pulling the magnet from the calibrated pellet (insert) of the indicator shall constitute failure. 5 Detail to be specified The following details shall be specified in the referencing document: 5.1 Number of specimens to be tested 5.2 Magnetic permeabi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36454A1999TP54AMAGNETICPERMEABILITYTESTPROCEDUREFORELECTRICALCONNECTORSCONTACTSANDSOCKETSTP54A

链接地址:http://www.mydoc123.com/p-704283.html