ECA EIA-364-113-2010 TP-113 Corrosivity of Contacts Test Procedure for Electrical Connectors and Sockets.pdf
《ECA EIA-364-113-2010 TP-113 Corrosivity of Contacts Test Procedure for Electrical Connectors and Sockets.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-113-2010 TP-113 Corrosivity of Contacts Test Procedure for Electrical Connectors and Sockets.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-113 Corrosivity of Contacts Test Procedure for Electrical Connectors and Sockets EIA-364-113 March 2010 Electronic Components Industry Association ANSI/EIA-364-113-2010 (R2016) Approved: June 4, 2010 Reaffirmed: April 13, 2016 EIA-364-113NOTICE EIA Engineering Standards and Publicat
2、ions are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need
3、. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those
4、other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner
5、, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA standard is considered to have International Standardization implications, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison betwee
6、n the EIA standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to dete
7、rmine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5204 and reaffirmed by Standards Proposal No. 5361.08, formulated under the cognizance of the EIA CE-2.0 Committee on National Connector and Socket Standards). Published by ELECTRONIC COMPONENTS INDUSTRY A
8、SSOCIATION 2016 Standards & Technology Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE ! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through
9、 entering into a license agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5186), International (303-397-7956) CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 2 Test resources 1 2.1 Material . 1 3 Test specimen 1 3.1 Descr
10、iption 1 3.2 Preparation 2 4 Test procedure . 2 5 Details to be specified . 4 6 Test documentation . 4 Table 1 Test conditions 3 i (This page left blank) ii EIA-364-113 Page 1 TEST PROCEDURE No. 113 CORROSIVITY OF CONTACTS TEST PROCEDURE FOR ELECTRICAL CONNECTOR AND SOCKET (From EIA Standards Propos
11、al No. 5204, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards.) 1 Introduction 1.1 Scope 1.1.1 This test procedure establishes a test method to determine whether corrosion products as a result of residual corrosive elements may be created on contact surfaces. Said
12、 products may be a result from improper cleaning or lack thereof, improper processes, entrapped particulates, etc. The following plating systems (but not limited to) are of interest. gold over copper (alloys) with or without nickel underplate, gold over palladium-nickel over copper (alloys) with or
13、without nickel underplate, silver plated systems with or without underplates. 1.1.2 This test procedure does not determine to what extent, if any, the performance of the product tested may be affected by the presence of residual corrosive elements on the contacts or connectors and any resulting corr
14、osion from the test exposure. Any effect that the existence of residual corrosive elements may have on product performance would be dependent on many factors including the product design, the location, type, concentration of residual corrosive elements, and the actual application of the product. 2 T
15、est resources 2.1 Material Noncorrosive string or equivalent 3 Test specimen 3.1 Description 3.1.1 Specimens shall be unassembled contacts (loose or on a carry strip). Contacts used in insert moldings shall be supplied loose prior to the molding operation. All contacts shall be tested in the as rece
16、ived condition, see 3.2.3 through 3.2.5. 3.1.2 Unplated control samples shall be from the same lot of contacts used in the insert molded assemblies, see 3.2.3 through 3.2.5. EIA-364-113 Page 2 3.2. Preparation 3.2.1 The test chamber shall be thoroughly cleaned, including the water pan for the humidi
17、ty generation. Deionized water shall be used. 3.2.2 A drip shield shall be used at an angle over the specimens under test to prevent stray water droplets from depositing on the test specimens. The drip shield shall be constructed of non-reactive material. 3.2.3 A minimum of 10 as received plated spe
18、cimens shall be attached to non-reactive string. An additional five specimens minimum, of the as received samples, shall be cleaned using ultrasonics and deionized water or equivalent process. A minimum of 10 control samples from connector assemblies shall also be prepared. All test specimens shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA3641132010TP113CORROSIVITYOFCONTACTSTESTPROCEDUREFORELECTRICALCONNECTORSANDSOCKETSPDF

链接地址:http://www.mydoc123.com/p-704217.html