ECA EIA-364-103-1999 TP-103 Propagation Delay Test Procedure for Electrical Connectors Sockets Cable Assemblies or Interconnection Systems《TP-103 电连接器、插座、电缆附件或互连系统传播延迟试验程序》.pdf
《ECA EIA-364-103-1999 TP-103 Propagation Delay Test Procedure for Electrical Connectors Sockets Cable Assemblies or Interconnection Systems《TP-103 电连接器、插座、电缆附件或互连系统传播延迟试验程序》.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-103-1999 TP-103 Propagation Delay Test Procedure for Electrical Connectors Sockets Cable Assemblies or Interconnection Systems《TP-103 电连接器、插座、电缆附件或互连系统传播延迟试验程序》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-103 Propagation Delay Test Procedure for Electrical Connectors, Sockets, CableAssemblies or Interconnection Systems EIA-364-103February 1999 ELECTRONIC COMPONENTS, ASSEMBLIES see figure 1.1.2.2 Specimen environment impedanceThe impedance presented to the signal conductors by the fix
2、ture. This impedance is a result oftransmission lines, termination resistors, attached receivers or signal sources, and fixtureparasitics.1.2.3 Propagation delayThe time required for a signal to travel between two specified points of an interconnect system;see figure 2.1.2.4 Termination (electronics
3、 usage)An impedance connected to the end of a transmission line, typically to minimize reflected energyon the line.EIA-364-103Page 22 Test resources2.1 Equipment2.1.1 Pulse generator and oscilloscope, TDR or other suitable equipment with a measurementsystem rise time less than or equal to the measur
4、ed propagation delay.2.1.2 ProbesProbes, where applicable, shall have suitable rise time performance and circuit loadingcharacteristics (resistance and capacitance).2.2 MaterialWhen the fixture is a printed circuit board, the reference trace and the test trace should be madeon the same printed circu
5、it board to reduce any difference in PCB fabrication processes, dielectricmaterial variations, etc.2.3 FixtureUnless otherwise specified in the referencing document the specimen environment impedance shallmatch the impedance of the test equipment. Typically this will be 50 ohms for single-endedmeasu
6、rements and 100 ohms for differential.2.3.1 Method A, single-endedThe fixture shall allow one signal line to be driven at a time. The driven line shall be terminatedaccording to one of the methods of figure A.2 with the specimen environment impedance. Unlessotherwise specified a 1:1 signal to ground
7、 ratio shall be used with each end having all groundscommoned. Each line adjacent to the driven line(s) shall also be terminated in the specimenenvironment impedance at both near and far ends.2.3.1.1 Probe techniqueThe fixture shall be designed to allow the signal to be probed at the two points betw
8、een which thedelay is to be measured; see figure A.1.a.2.3.1.2 Insertion techniqueThe fixture shall be designed to allow measurement of propagation delay with and without thespecimen; see figure A.1.b.EIA-364-103Page 32.3.1.3 Reference fixture techniqueTwo fixtures shall be designed that include the
9、 same fixture electrical length and characteristics ofenvironment transmission line. The “specimen fixture” includes the specimen. The “referencefixture” does not include the specimen. The fixture electrical length does not include thespecimen length; see figure A.1.c.2.3.2 Method B, differentially
10、drivenThe fixture shall allow one signal pair to be driven at a time. The driven line shall be terminatedaccording to one of the methods of figure A.3 with the specimen environment impedance. Unlessotherwise specified a 2:1 signal to ground ratio shall be used. Each line adjacent to the drivenline(s
11、) shall also be terminated in the specimen environment impedance at both near and far ends.2.3.2.1 Probe techniqueThe fixture shall be designed to allow the signal pair to be probed at the points between which thedelay is to be measured; see figure A.1.a.2.3.2.2 Insertion techniqueThe fixture shall
12、be designed to allow measurement of propagation delay with and without thespecimen; see figure A.1.b.2.3.2.3 Reference fixture techniqueTwo fixtures shall be designed that include the same fixture electrical length and characteristics ofthe environment transmission line. The “specimen fixture” inclu
13、des the specimen. The “referencefixture” does not include the specimen. The fixture electrical length does not include thespecimen length; see figure A.1.c.3 Test Specimen3.1 DescriptionFor this test procedure the test specimen shall be as follows:3.1.1 Separable connectorsA mated connector pair.3.1
14、.2 Cable assemblyAssembled connectors and cables, and mated connectors.3.1.3 SocketsEIA-364-103Page 4A socket and test device or a socket and pluggable header adapter.4 Test procedureUnless otherwise specified the measurement system rise time shall be less than or equal to themeasured delay. The mea
15、surement system rise times specified in table 1 are recommended. Thethree techniques below apply to single-ended and differential measurements. For differentialmeasurements, it is necessary to determine whether any phase and/or amplitude errors existbetween the probe/channels and to provide necessar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA3641031999TP103PROPAGATIONDELAYTESTPROCEDUREFORELECTRICALCONNECTORSSOCKETSCABLEASSEMBLIESORINTERCONNECTIONSYSTEMSTP103

链接地址:http://www.mydoc123.com/p-704197.html