《ECA EIA-364-101-2000 TP-101 Attenuation Test Procedure for Electrical Connectors Sockets Cable Assemblies or Interconnection Systems《TP-101 电连接器、插座和电缆组件或内连接系统的衰减试验程序》.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-101-2000 TP-101 Attenuation Test Procedure for Electrical Connectors Sockets Cable Assemblies or Interconnection Systems《TP-101 电连接器、插座和电缆组件或内连接系统的衰减试验程序》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-101 Attenuation Test Procedure for Electrical Connectors, Sockets, Cable Assemblies or Interconnection Systems EIA-364-101 May 2000 ANSI/EIA-364-101-2000(R2013) Approved: March 10, 2000 Reaffirmed: January 15, 2013 EIA-364-101 NOTICE EIA Engineering Standards and Publications are de
2、signed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence
3、 of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than
4、ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does
5、it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA St
6、andard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the ap
7、plicability of regulatory limitations before its use. (From Standards Proposal No. 4153-A, formulated under the cognizance of the EIA CE-2.0 National Connector Standards Committee and reaffirmed per Standards Proposal No. 5253.05). Published by Electronic Components Industry Association 2013 EIA Sta
8、ndards see figure A.1.a. If baluns are used for a measurement, or minimum loss pads used for impedance matching, these are included in the fixture. Figures A.2 and A.3. show typical configurations with minimum loss pads. 2.2.4 Reference fixture technique In this technique a separate fixture that com
9、bines both near end and far end is used for the fixture attenuation measurement; see figure A.1.b. This fixture shall be a duplicate of the specimen fixture, only without the specimen. Traces, if used, shall include fixture connectors, vias, bends, and corners. If baluns are used for a differential
10、measurement, or minimum loss pads used for impedance matching, these are included in the fixturing. Figures A.2 and A.3. show typical configurations with minimum loss pads. 3 Test Specimen 3.1 Description For this test procedure the test specimen shall be as follows: NOTE As the specimen length appr
11、oaches wavelength, careful interpretation of the results is required due to possible resonance effects. It is recommended t hat the specimen electrical length be 1/8 the wavelength of the maximum test frequency. 3.1.1 Separable connectors A mated pair with identified signals and grounds. 3.1.2 Cable
12、 assembly Assembled connectors and cable, and mating connector(s) with identified signal and ground contacts and wires. 3.1.3 Sockets A socket and test device or a socket and pluggable header adapter with identified signal and grounds. EIA-364-101 Page 4 4 Test procedure Unless otherwise specified a
13、ll measurement results shall contain a minimum of 200 frequency points. Each fixture measurement and its associated specimen attenuation measurement shall be taken at the same frequencies. Generate a magnitude versus frequency plot; 1 dB per division vertical scale and log frequency sweep are recomm
14、ended. When applicable, single frequency results shall be tabulated, as specified in the referencing document. Place the specimen a minimum of 5 cm from any objects that would affect measured results. NOTE The test professional should be aware of limitations of any math operation performed by an ins
15、trument, (e.g. normalization or software filtering). 4.1 Fixture attenuation Fixture attenuation shall be measured separately so that it can be removed from and compared to the specimen measurement. If the referencing document precisely specifies the fixture so that its attenuation contribution is f
16、ixed, then the fixture attenuation measurement is optional. NOTES Results may be inaccurate when: 1 The fixture attenuation is greater than the specimen attenuation. 2 The fixture electrical length is greater than 1/8 wavelength at the highest test frequency, unless special precautions are taken to
17、ensure good impedance matching throughout the measurement path. This can be confirmed by sweeping across a wide frequency range and observing if there are nulls due to moding, fixture or balun resonances, etc. 4.2 Method A, frequency domain 4.2.1 Network or spectrum analyzer (direct technique) 4.2.1
18、.1 Calibration 4.2.1.1.1 When using a network analyzer, at a minimum, a “through“ calibration at the reference plane (include analyzer cables but not specimen fixture) shall be performed. Where possible a 12 term calibration is recommended. 4.2.1.1.2 When using a spectrum analyzer and signal generat
19、or, take a reference measurement similarly. The generator output shall be kept the same for both fixture and specimen-with-fixture attenuation measurements made later. EIA-364-101 Page 5 4.2.1.2 Insertion technique 4.2.1.2.1 Assemble the fixture so that the near end is connected to the far end witho
20、ut the specimen in between; see figure A.1.a. Connect the network analyzer ports, or the signal generator and spectrum analyzer, to the appropriate locations of the driven line fixture. 4.2.1.2.2 When using a network analyzer measure the fixture attenuation (S21). 4.2.1.2.3 When using a spectrum ana
21、lyzer, measure the power from the generator through the fixture. Then divide the magnitude of this signal by that of the reference measurement performed in 4.2.1.1.2 at each frequency (subtract dB). This is the fixture attenuation. 4.2.1.3 Reference fixture technique 4.2.1.3.1 Construct a reference
22、fixture that duplicates the specimen fixture but without the specimen. Include both near and far ends; see figure A.1.b. Connect the network analyzer ports, or the signal generator and spectrum analyzer to the appropriate locations of the driven line fixture. 4.2.1.3.2 When using a network analyzer,
23、 measure the fixture attenuation (S21). 4.2.1.3.3 When using a spectrum analyzer, measure the power from the generator through the fixture. Then divide the magnitude of this signal by that of the reference measurement performed in 4.2.1.2.3 at each frequency (subtract dB). This is the fixture attenu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA3641012000TP101ATTENUATIONTESTPROCEDUREFORELECTRICALCONNECTORSSOCKETSCABLEASSEMBLIESORINTERCONNECTIONSYSTEMSTP101

链接地址:http://www.mydoc123.com/p-704193.html