DLA W-C-596 G (2)-2001 CONNECTOR ELECTRICAL POWER GENERAL SPECIFICATION FOR [Use In Lieu Of DLA W-C-00596 C]《电源连接器通用规格[使用代替 DLA W-C-00596 C]》.pdf
《DLA W-C-596 G (2)-2001 CONNECTOR ELECTRICAL POWER GENERAL SPECIFICATION FOR [Use In Lieu Of DLA W-C-00596 C]《电源连接器通用规格[使用代替 DLA W-C-00596 C]》.pdf》由会员分享,可在线阅读,更多相关《DLA W-C-596 G (2)-2001 CONNECTOR ELECTRICAL POWER GENERAL SPECIFICATION FOR [Use In Lieu Of DLA W-C-00596 C]《电源连接器通用规格[使用代替 DLA W-C-00596 C]》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 W-C-596G/GEN AMENDMENT 2 3 October 2001 SUPERSEDING AMENDMENT 1 8 September 1998 FEDERAL SPECIFICATION CONNECTOR, ELECTRICAL, POWER, GENERAL SPECIFICATION FOR The General Services Administration has authorized the use of this amendment, which forms a part of W-C-596G/GEN, dated 28 April 1995, by al
2、l federal agencies. PAGE 1 2.1, under Government publications, delete: “Military Specification MIL-C-55330 - Connectors, Electrical and Fiber Optic, Packaging of.” Delete beneficial comments block and substitute; “ Beneficial comments (recommendations, additions, deletions) and any pertinent data wh
3、ich may be of use in improving this document should be addressed to: Defense Supply Center Columbus, ATTN: DSCC-VAI, 3990 East Broad Street, Columbus, OH 43216-5000 by using the self addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by le
4、tter. ” PAGE 2 2.2, under Other publications, delete “UL 498 - Standard for Attachment Plugs and Receptacles”, and substitute: “ANSI/UL 498 - Standard for Attachment Plugs and Receptacles ANSI/UL 943 - Standard for Ground-Fault Circuit-Interrupters” 3.2.1, delete and substitute: “3.2.1 UL or CSA ver
5、ified connectors. Each contractor shall submit to the contracting agency proof that the connectors supplied under this specification conform to the requirements of American National Standard ANSI/UL 498 and applicable bulletins and, where relevant, of American National Standard ANSI/UL 943 and appli
6、cable bulletins. The U.S. listing mark of Underwriters Laboratories, Inc. (UL) or the U.S. certification mark of Canadian Standards Association (CSA/NRTL), may be accepted as evidence that the connectors conform to ANSI/UL 498 requirements for general grade connectors and to additional ANSI/UL 943 r
7、equirements for general grade connectors incorporating ground-fault circuit interrupter protection for personnel. The above listing mark and the green dot of ANSI/UL 498 may be accepted as evidence that the connectors conform to ANSI/UL 498 requirements for hospital grade connectors.” AMSC N/A 1 of
8、5 FSC 5935 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.INCH-POUNDProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-C-596G/GEN AMENDMENT 2 2 3.2.2, delete and substitute: “3.2.2 Non-UL or NON-CSA verified connector
9、s. In lieu of the listing mark or listing mark and hospital grade green dot of ANSI/UL 498, the contractor shall submit independent proof, satisfactory to the contracting agency, that the connectors conform to the applicable requirements, including methods of tests, of the published standards of ANS
10、I/UL 498 and, where applicable, ANSI/UL 943.” “NOTE: ANSI/UL 498 and ANSI/UL 943 will hereinafter be referred to as UL 498 and UL 943, respectively.” 3.5.1, delete and substitute: “3.5.1 Mounting flanges and plates. Unless otherwise specified (see 3.1), mounting flanges and plates of ferrous materia
11、l shall be protected against corrosion by galvanizing or by electrodeposition of a suitable metal. Painting alone is not acceptable.” PAGE 5 3.6.14, delete “UL tests.” and substitute, “UL 498 tests.” 3.7.1.1, delete and substitute: “3.7.1.1 General grade. Each connector shall be marked in accordance
12、 with UL 498 with the manufacturers trade mark and electrical rating (see 3.1). In addition, a Federal Specification verification mark shall appear on connectors that have met all the requirements of this specification. The Federal Specification verification mark shall be “FS-UL” or “FS-CSA” as appl
13、icable or the initials “FS” adjacent to the registered trade mark of UL or CSA. NOTE: Under the Federal Specification verification program manufacturers may mark a connector with the Federal Specification verification mark even though there is no W-C-596 specification sheet for that connector. Howev
14、er, the connector must comply with all the performance requirements of W-C-596. (This allows for broader use in manufacturing of common parts on which the manufacturer may choose to place the Federal Specification verification mark.)” 3.7.1.2, delete note. 3.7.2, delete and substitute: “3.7.2 Connec
15、tors not supplied under the Federal Specification verification program. Each connector shall be marked with the manufacturers trade mark and electrical rating (see 3.1). Connectors meeting the performance and test requirements of this specification shall be marked with the W-C-596 Part Identificatio
16、n Number (PIN) in accordance with MIL-STD-1285. The Federal Specification verification mark shall not appear on this category of connectors (see 1.2). The registered trade mark of UL or CSA shall not appear on the connector unless the device separately has UL or CSA listing for the specific grade.”
17、3.7.3, delete and substitute: “3.7.3 Package marking. The smallest unit carton or package shall be marked as specified in the contract or order (see 5.1). NOTE: Inclusion of the W-C-596 PIN and a packaging date code is optional, though suggested.Provided by IHSNot for ResaleNo reproduction or networ
18、king permitted without license from IHS-,-,-W-C-596G/GEN AMENDMENT 2 3 PAGE 6 4.4b., delete and substitute: “b. By having Underwriters Laboratories or Canadian Standards Association listing and Federal Specification verification. Manufacturers electing this option shall submit a letter of certificat
19、ion to the qualifying activity listing the Underwriters Laboratories or the Canadian Standards Association file number, report date, the Government PIN and the manufacturers PIN for each connector for which qualification is desired. Qualification approval may be granted upon successful completion of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAWC596G22001CONNECTORELECTRICALPOWERGENERALSPECIFICATIONFORUSEINLIEUOFDLAWC00596C 电源 连接器 通用 规格 使用 代替

链接地址:http://www.mydoc123.com/p-701562.html