DLA W-C-375 6 D-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP TWO POLE (15 THROUGH 125 AMPERES).pdf
《DLA W-C-375 6 D-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP TWO POLE (15 THROUGH 125 AMPERES).pdf》由会员分享,可在线阅读,更多相关《DLA W-C-375 6 D-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP TWO POLE (15 THROUGH 125 AMPERES).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5925 W-C-375/6D 14 May 2009 SUPERSEDING W-C-375/6C 04 August 2004 FEDERAL SPECIFICATION SHEET CIRCUIT BREAKERS, MOLDED CASE, BRANCH CIRCUIT AND SERVICE, TYPE I, SERIES TRIP, TWO POLE (15 THROUGH 125 AMPERES) The General Services Administration has authorized the use of this federal spec
2、ification sheet by all federal agencies. The complete requirements for procuring circuit breakers described herein shall consist of this document and the latest issue in effect of W-C-375. FIGURE 1. Interface and physical dimensions (15 through 70 amperes). INCH-POUND Provided by IHSNot for ResaleNo
3、 reproduction or networking permitted without license from IHS-,-,-W-C-375/6D 2 Inches mm Inches mm Inches mm Inches mm Inches mm .003 .08 .031 .79 .235 5.97 .562 14.27 1.478 37.54 .008 .20 .070 1.78 .243 6.17 .565 14.35 1.480 37.59 .010 .25 .110 2.79 .250 6.35 .594 15.09 2.187 55.55 .013 .33 .125 3
4、.18 .280 7.11 .70 17.8 2.312 58.72 .015 .38 .130 3.30 .290 7.37 .700 17.78 2.402 61.01 .016 .41 .140 3.56 .320 8.13 .719 18.26 2.500 63.50 .02 .5 .141 3.58 .375 9.52 .950 24.13 2.59 65.8 .020 .51 .187 4.75 .424 10.77 .952 24.18 3.000 76.20 .03 .8 .218 5.54 .429 10.90 1.17 29.7 3.045 77.34 .030 .76 .
5、230 5.84 .495 12.57 1.128 28.65 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are 0.01 (0.25 mm) for two-place decimals and 0.005 (0.13 mm) for three-place decimals and 1 on angles. 4. Load terminals shall
6、be suitable for copper (CU) and aluminum (AL) wire. FIGURE 1. Interface and physical dimensions (80 through 125 amperes) - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-C-375/6D 3 REQUIREMENTS: Interface and physical dimensions: See fi
7、gure 1 and 2. Trip indication: See figure 1 and 2. Common trip: All poles shall make and break simultaneously when operated manually or automatically. Electrical: Interrupting current rating: 10,000 amperes. Voltage rating: 120/240 V ac. Currency rating: See table I. Frequency: 60 hertz. Calibration
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAWC3756D2009CIRCUITBREAKERSMOLDEDCASEBRANCHCIRCUITANDSERVICETYPEISERIESTRIPTWOPOLE15THROUGH125AMPERESPDF

链接地址:http://www.mydoc123.com/p-701444.html