DLA MIL-PRF-85045 29 A-2009 CABLE FIBER OPTIC TWELVE EIGHTEEN FIBER BUNDLE BLOWN OPTICAL FIBER CABLE CONFIGURATION TYPE 3 (CABLE BUNDLE) APPLICATION B (SHIPBOARD) CABLE CLASS SM AN.pdf
《DLA MIL-PRF-85045 29 A-2009 CABLE FIBER OPTIC TWELVE EIGHTEEN FIBER BUNDLE BLOWN OPTICAL FIBER CABLE CONFIGURATION TYPE 3 (CABLE BUNDLE) APPLICATION B (SHIPBOARD) CABLE CLASS SM AN.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-85045 29 A-2009 CABLE FIBER OPTIC TWELVE EIGHTEEN FIBER BUNDLE BLOWN OPTICAL FIBER CABLE CONFIGURATION TYPE 3 (CABLE BUNDLE) APPLICATION B (SHIPBOARD) CABLE CLASS SM AN.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-85045/29A 14 May 2009 SUPERSEDING MIL-PRF-85045/29 27 March 2007 PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, TWELVE/EIGHTEEN FIBER BUNDLE, BLOWN OPTICAL FIBER CABLE CONFIGURATION TYPE 3 (CABLE BUNDLE), APPLICATION B (SHIPBOARD), CABLE CLASS SM AND MM, (METRIC) This specification is
2、approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-85045. CLASSIFICATION: Fiber optic cable configuration type (cable bundle): 3. Fiber cable class: MM (grade
3、d-index, glass core and glass cladding, multimode) SM (dispersion-unshifted, glass core and glass cladding, single mode). FIGURE 1. Blown optical fiber bundle cable. AMSC N/A FSC 6015 METRIC Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-850
4、45/29A 2 Part or Identifying Number (PIN): 12-fiber bundle cable (multimode): M85045/29-0112 18-fiber bundle cable (multimode): M85045/29-0118 12-fiber bundle cable (single mode): M85045/29-0212 18-fiber bundle cable (single mode): M85045/29-0218 DESIGN AND CONSTRUCTION: Fiber: Type MM fibers shall
5、be in accordance with MIL-PRF-49291/6. Type SM fibers shall be in accordance with MIL-PRF-49291/7. Buffer diameter: 250 15 m. Finished cable: Dimensions and configuration: See figure 1. An outer jacket shall be applied over three optical fiber bundle sub-units with rip cords in each sub-unit. OFCC k
6、ink: Not applicable. Color: Slate or blue (MIL-PRF-49291/6 fiber). Yellow (MIL-PRF-49291/7 fiber). Concentricity: Applicable with the following modification. The concentricity shall be measured by first locating the areas where the binder/inner jacket is nearest the jacket outside diameter. From the
7、se measurements the minimum and the maximum wall thicknesses will be selected and used to calculate concentricity. The ratio of the minimum wall thickness to the maximum wall thickness shall be 0.50. Jacket material: The overall jacket shall be composed of a low halogen, low toxicity polymer materia
8、l. Mass per unit length: 6 kg/km. Short-term minimum bend diameter: 76 mm. (The short term minimum bend diameter is to be used in all environmental and mechanical tests that specify a cable minimum bend diameter.) Long term minimum bend diameter: 76 mm. Minimum continuous length: The minimum continu
9、ous length of all cables shall be not less than 0.5 km. If lengths less than 0.5 km are specified in the purchase order, the delivered cable shall be accompanied by certified test data demonstrating that the conformance inspection was performed on a test specimen not less than 0.5 km in length. Prov
10、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-85045/29A 3 Marking: Marking of blown optical fiber bundles is not required. Shipping containers and bundle reels shall be marked. Fiber color coding: See table I. TABLE I. Fiber color coding. Sub-u
11、nit number Position number Fiber color 12-fiber bundle 18-fiber bundle 1 1 Blue Blue 2 Orange Orange 3 N/A - ripcord Green 4 Green Brown 5 Brown Slate 6 N/A - ripcord N/A - ripcord 7 N/A - ripcord Red 2 1 Slate Blue 2 White Orange 3 N/A - ripcord Green 4 Red Brown 5 Black Slate 6 N/A - ripcord N/A -
12、 ripcord 7 N/A - ripcord Violet 3 1 Yellow Blue 2 Violet Orange 3 N/A - ripcord Green 4 Pink Brown 5 Aqua Slate 6 N/A - ripcord N/A - ripcord 7 N/A - ripcord Yellow NOTE: PINs M85045/29-0112 and M85045/29-0212 only contain 4 fibers in each sub-unit. PERFORMANCE REQUIREMENTS: Optical properties: Maxi
13、mum attenuation rate: 3.75 dB/km at 850 20 nm, 1.25 dB/km at 1,300 20 nm for type MM fiber. 0.75 dB/km at 1,310 20 nm and 1,550 20 nm for type SM fiber. Bandwidth: Fiber with a minimum bandwidth of 500 MHz-km at 1,300 nm shall be used (multimode cables only). Bandwidth is not specified at 850 nm. Ch
14、ange in optical transmittance: Measurements to be made at 1,300 20 nm. For shock testing only four fibers are required to be monitored. (At least one fiber per sub-unit.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-85045/29A 4 Crosstalk:
15、Applicable. Mechanical properties: Tensile loading and elongation: Not applicable. Operating tensile loading: Not applicable. Dynamic bend: Not applicable. Low temperature flexibility: Not applicable. Cyclic flexing: 500 cycles at +25oC 2oC and 100 cycles at 28oC 2oC. Minimum load shall be 1.0 kg. C
16、hange in optical transmittance measurements are to be made every 100 cycles for the 500-cycle exposure and every 25 cycles for the 100-cycle exposure. Each change in optical transmittance measurement shall be performed with the test specimen in the same position in the test cycle. The cycling may be
17、 halted to perform the change in optical transmittance measurement. At low temperature, splitting, cracking or crazing of bundle jacket may be permitted so long as there is no splitting, cracking, or crazing of inner jacket. Crush: Not applicable. Cable twist bending: Not applicable. Impact: Not app
18、licable Corner bend: Not applicable. Dripping: Applicable. Cable jacket tear strength: Applicable, except the cable jacket tear strength shall be 5 N/cm minimum. Test shall be performed on test samples in shear orientation. Cable scraping resistance: Not applicable. Cable to cable abrasion: Not appl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF8504529A2009CABLEFIBEROPTICTWELVEEIGHTEENFIBERBUNDLEBLOWNOPTICALFIBERCABLECONFIGURATIONTYPE3CABLEBUNDLEAPPLICATIONBSHIPBOARDCABLECLASSSMANPDF

链接地址:http://www.mydoc123.com/p-693097.html