《DLA MIL-PRF-39012 4 F-2013 CONNECTORS COAXIAL RADIO FREQUENCY (SERIES N (UNCABLED) RECEPTACLES JAM NUT AND FLANGE MOUNTED SOCKET CONTACT CLASS 2).pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-39012 4 F-2013 CONNECTORS COAXIAL RADIO FREQUENCY (SERIES N (UNCABLED) RECEPTACLES JAM NUT AND FLANGE MOUNTED SOCKET CONTACT CLASS 2).pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-39012/4F 14 August 2013 SUPERSEDING MIL-PRF-39012/4E 16 November 2006 PERFORMANCE SPECIFICATION SHEET CONNECTORS, COAXIAL, RADIO FREQUENCY (SERIES N (UNCABLED) RECEPTACLES JAM NUT AND FLANGE MOUNTED, SOCKET CONTACT, CLASS 2) This specification is approved for use by all Departments and Agen
2、cies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-39012. FIGURE 1. General configuration. AMSC N/A FSC 5935 INCH-POUND -X002 -X001 Provided by IHSNot for ResaleNo reproduction or networking permitted w
3、ithout license from IHS-,-,-MIL-PRF-39012/4F 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. See table I for dimensions A, B, C, and D. 4. Dimensions A and B are the largest overall dimensions of the receptacles except the flange height and width on das
4、h number 0002 or 7002. 5. All undimensioned pictorial configurations are for reference purposes only. 6. Receptacle dash number 0002 or 7002 not recommended for use on panels with greater than .071 (1.80 mm) max thickness. 7. Full threads to within .063 inch (1.60 mm) of shoulder; 1 1/2 max uneven t
5、hreads to shoulder. 8. There shall be a solid barrier in the socket between the pin entry and the solder pocket to prevent solder wicking. 9. Interface is a series N socket contact in accordance with MIL-STD-348. FIGURE 1. General configuration Continued. Inches mm Inches mm .022 0.56 .532 13.49 .11
6、0 2.79 .543 13.79 .120 3.05 .625 15.88 .130 3.30 .630 16.00 .250 6.35 .645 16.38 .354 8.99 .713 18.11 .364 9.25 .723 18.36 .492 12.50 .745 18.92 .503 12.78 .755 19.18 .526 13.36 .985 25.02 .531 13.49 1.005 25.53 -X003 Provided by IHSNot for ResaleNo reproduction or networking permitted without licen
7、se from IHS-,-,-MIL-PRF-39012/4F 3 TABLE I. Dash numbers, cross-reference, and dimensions. Dash number 1/ Type Dimension Inches (millimeters) 2/ Min Max 0001 3/ 7001 3/ Bulkhead (front mounted hermetic sealed) A B C D - - 1.125 (25.40) .702 (17.83) 1.750 (44.45) .885 (22.48) 1.250 (31.75) .721 (18.0
8、8) 0002 3/ 7002 3/ Flange (rear mounted) A B C D 1.062 (26.97) .620 (15.65) .721 (18.31) .075 (1.91) 1.156 (26.36) .670 (17.02) .751 (19.08) .085 (2.16) 0003 3/ 7003 3/ Bulkhead (rear mounted) A B C - .850 (21.59) .912 (23.16) 1.343 (34.11) .900 (22.86) .940 (23.88) 1/ For cross-reference of dash nu
9、mber to superseded Part or Identifying Number (PIN) or type designation, see table III. 2/ Dimensions are in inches. Metric equivalents are given for information only. 3/ These connectors have captivated center contacts. ENGINEERING DATA: Nominal impedance: 50 ohms. Frequency range: 0 to 11 GHz. Vol
10、tage rating 1,000 volts rms maximum working voltage at sea level. 250 volts rms maximum at 70,000 feet (4.437 kPa). Temperature rating: -65C to +165C. REQUIREMENTS: Design and configuration: See figure 1. Force to engage and disengage: Longitudinal force: Not applicable. Torque: 6 inch-pounds (.68 N
11、m) maximum. Coupling proof torque: Not applicable. Inspection conditions: Coupling torque: 6 to 10 inch-pounds (.68 to 1.13 Nm). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-39012/4F 4 Mating characteristics: In accordance with MIL-STD-348
12、. Contact with spring members: Center contact (socket): Oversize test pin: .074 inch (1.88 mm), diameter minimum (nonclosed entry contacts only). Insertion depth: .125 inch (3.17 mm), minimum. Number of insertions: 1. Insertion force test: Steel test pin diameter .066 inch (1.68 mm), minimum. Test p
13、in finish: 16 microinches (0.406 m). Insertion force: 2 pounds (8.90 N) maximum. Withdrawal force test: Steel test pin diameter .063 inch (1.60 mm), maximum. Withdrawal force: 2 ounces (.56 N) minimum. Test pin finish: 16 microinches (0.406 m). Hermetic seal: Applicable to M39012/04-0001 and M39012/
14、04-7001. (Leakage shall not exceed 1 x 10-7cm3/s of tracer gas at atmospheric pressure) Leakage (pressurized connectors): Applicable to M39012/04-0001, M39012/04-0003, M39012/04-7001 and M39012/04-7003. The receptacle shall be mounted in its normal manner on a closed container with the mating end ca
15、pped. Container interior air pressure shall be 30 psi. Insulation resistance: Method 302 of MIL-STD-202, test condition B. 5,000 megohms minimum. Center contact retention: 6 pounds (26.69 N) minimum axial force. Corrosion (salt spray): Method 101 of MIL-STD-202. Voltage standing wave ratio (VSWR): N
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF390124F2013CONNECTORSCOAXIALRADIOFREQUENCYSERIESNUNCABLEDRECEPTACLESJAMNUTANDFLANGEMOUNTEDSOCKETCONTACTCLASS2PDF

链接地址:http://www.mydoc123.com/p-692872.html