1、I INCH-POUND I MIL-DTL-44400A 7 April, 2000 SUPERSEDING 11 April, 1990 . MIL-T-44400( GL) DETAILED SPECIFICATION TENT, FABRIC ASSEMBLIES, STANDARDIZED INTEGRATED COMMAND POST SYSTEM This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scop
2、e. This specification covers the fabric components of a frame-supported tent equipped, which can stand-alone or be complexed with other tents or vehicles. 1.2 Classification. (see 6.2) Class I Class II - Camouflage Green 483 - Desert Tan 459 2. APPLICABLE DOCUMENTS “2.1 General. The documents listed
3、 in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document
4、 users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. Beneficial comments (recommendations, additions, deletions, clarifications) and any pertinent data which may be of use in improving this docu
5、ment should be addressed to: Defense Supply Center Philadelphia, Clothing and Textiles Directorate, Attn: DSCP-CNR, 700 Robbins Ave., Philadelphia, PA 19111-5096 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC
6、 8340 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-44400A 2.2 Government documents. “2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specifie
7、d herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS FEDERAL DDD-L-20 - Label; For Clothing, Equipage a
8、nd Tentage (General Use) STANDARDS FEDERAL FED-STD-601 - Rubber: Sampling and Testing (Unless otherwise indicated. copies of federal and military specifications, standards, and handbooks are available from the Defense Automated Printing Service, Bldg. 4D (DPM- DODSSP), 700 Robbins Avenue, Philadelph
9、ia, PA 191 11-5094.) “2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DEPARTMENT
10、 OF THE ARMY FIELD MANUAL FM 10-16 - General Repair of Tents, Canvas and Webbing (Applications for copies should be addressed to the Superintendent of Documents, US Government printing office, Washington, DC 20402) DRAWINGS U.S. ARMY BIOLOGICAL AND CHEMICAL COMMAND 5-4-6341 - Fabric Assemblies Overv
11、iew 5-4-7676 - Instruction Label, Five Soldier Crew Tent 5-4-7678 - FSCT Pegs, Bag - more than ?A inch but not more than 1 inch - more than 1 inch 313 212 Burn through 112 Note: A seam shall be classified as open when one or more stitches joining a seam are broken, or when one or more skipped or run
12、-off stitches occur. On double stitched seams, a seam shall be classified as open when either one or both sides of a seam are open. Raw edges caught in stitching: - more than 1 inch but not more than 3 inches - more than 3 inches Note: Raw edge not securely caught in stitching shall be classified as
13、 an open seam Thread breaks: - overstitched less than 1 ?h inches on - overstitched less than 1 inch on stitch type 401 stitch type 301 Note: Thread breaks or two or more consecutive skipped or runoff stitches not overstitched shall be classified as an open seam Needle chews resulting in cut, tear o
14、r hole (see cut, tear or hole) Skipped stitches: - Overstitched less than 1 ?h inches - Overstitched less than 1 inch skipped stitches occur consecutively) on stitch type 401 on stitch type 301 (when 2 or more 314 213 315 316 214 215 9 Provided by IHSNot for ResaleNo reproduction or networking permi
15、tted without license from IHS-,-,-MIL-DTL-44400A TABLE I. &d item visual defects (cont Classification Examine Defect Maior Minor A B NOTE: Skipped stitches not overstitched shall be classified as open seams One or more required rows of stitching omitted (except on boxstitching) 113 114 Heat sealed s
16、eams Pleated, puckered, burned through, wrinkled or folded B oxstitching Incomplete: - one row of stitching omitted - two or more rows of stitching omitted More or less than specified length by more than 1/8 inch 317 216 318 Bartacking One or more bartacks omitted Any bartack not as specified or not
17、 in Loose stitching incomplete or broken Less than specified length by more than 1/8 inch Width less than 1/8 inch 115 specified location 319 320 321 217 Stitching ends Overstitched less than 1 inch on stitch type 301 (except where ends are held down by other stitching or turned under in a hem or wh
18、ere stitching is performed automatically) Secured with less than ?A inch of back stitching, Overstitching, or an increased number of stitches per inch at the end of stitch type 304 218 322 Seams Seam type Stitch type Stitch tension Stitches per inch Pleated: - on all wall, liner or floor assemblies
19、- on transport covers 219 323 Wrong seam type 116 117 Wrong stitch type Loose, resulting in exposed bobbin or top Tight, as evidenced by puckering on fabric thread for more than 6 inches for more than 6 inches 220 221 Less than minimum specified (except on panel joining seams) - one stitch - two or
20、more stitches Less than minimum specified on panel joining seams 324 222 223 10 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-44400A TABLE I. End item visual defects (&nt Classification Examine Defect Maior Minor A B More than the maximum s
21、pecified: - one stitch 325 - two or more stitches 224 Note: Variation in the number of stitches per inch, caused by the operator speeding up the machine and pulling the fabric in order to sew over heavy places or heavy seams or in turning corners shall be classified as follows: Stitching gage Not as
22、 specified Stitching margin (including tolerance): Larger or smaller than specified - for more than 2 inches but not more than 4 inches in length - for more than 4 inches in length Mends, darns Repairs not in accordance with Department or patches of The Army Field Manual FM 10-16 or not authorized b
23、y the contracting officer (see 3.3.8) 118 Components & assembly Any operation omitted or not performed in accordance with specification or drawing unless classified herein 119 Reinforce- Improperly applied, causing excessive fullness ments, on reinforcements or reinforced parts 120 Marking & labels
24、Omitted, incorrect, illegible, or misplaced: 225 326 226 327 Cleanness Grease or oil stains Thread ends not trimmed to ?h inch or less 328 4.3.4 End item dimensional examination. The end item shall be examined for the defects listed in Table II. Only those dimensions that can be evaluated without da
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL44400A2000TENTFABRICASSEMBLIESSTANDARDIZEDINTEGRATEDCOMMANDPOSTSYSTEM 规范化 综合 指挥所 系统 组织机构 帐篷

链接地址:http://www.mydoc123.com/p-690803.html