DLA MIL-DTL-25308 C-2010 GAGE PRESSURE DIAL INDICATING HYDRAULIC TYPE ME-1.pdf
《DLA MIL-DTL-25308 C-2010 GAGE PRESSURE DIAL INDICATING HYDRAULIC TYPE ME-1.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-25308 C-2010 GAGE PRESSURE DIAL INDICATING HYDRAULIC TYPE ME-1.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to Defense Logistic Agency Aviation VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5610 or emailed to STDZNMGTdla.mil. Since contact information can change, you may want to verify the currency of this address information
2、 using the ASSIST Online database at https:/assist.daps.dla.mil. AMSC N/A FSC 6685 MIL-DTL-25308C 1 November 2010 Superseding MIL-G-25308B 2 December 1971 DETAIL SPECIFICATION GAGE, PRESSURE, DIAL INDICATING, HYDRAULIC, TYPE ME-1 1. SCOPE 1.1 Scope. This specification covers the requirements for one
3、 type of hydraulic, dial indicating, pressure gage, designated type ME-1. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or rec
4、ommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2
5、.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks of the exact revision listed below form a part of this document to the extent specified herein. INCH-POUND Inactive for new design after 9 March 1999. Provided by IHSNot fo
6、r ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-25308C 2 FEDERAL STANDARD FED-STD-595/37038 - Black, Flat or Lusterless FED-STD-595/37875 - White, Flat or Lusterless DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-5541 - Chemical Conversion Coatings on Aluminum and
7、Aluminum Alloys MIL-PRF-6085 - Lubricating Oil: Instrument, Aircraft, Low Volatility MIL-S-7742 - Screw Threads, Standard, Optimum Selected Series: General Specification for MIL-A-8625 - Anodic Coatings for Aluminum and Aluminum Alloys MIL-B-27497 - Bearing, Jewel, Sapphire or Ruby, Synthetic MS2810
8、5 - Cover Glass, Aircraft Instrument Dial MS33639 - Cases, Instrument, Clamp-mounted, Aircraft DEPARTMENT OF DEFENSE STANDARDS MIL-STD-130 - Identification Marking of U.S. Military Property MIL-STD-810 - Environmental Engineering Considerations and Laboratory Tests MIL-STD-810B, Notice 1 - Environme
9、ntal Test Methods, dated 20 October 1969, method 514.1 Vibration test only MIL-STD-810B - Environmental Test Methods, dated 15 June 1967 and including corrections of Notice 4 dated 21 September 1970, method 504 Temperature-Altitude test only MIL-STD-889 - Dissimilar Metals DEPARTMENT OF DEFENSE HAND
10、BOOKS MIL-HDBK-781 - Reliability Test Methods, Plans, and Environments for Engineering Development, Qualification, and Production MIL-HDBK-831 - Preparation of Test Reports (Copies of the above documents are available from the Standardization Documents Order Desk, 700 Robbins Avenue, Building 4D, Ph
11、iladelphia, PA 19111-5094 or online at https:/assist.daps.dla.mil.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-25308C 3 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein.
12、 Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. SAE INTERNATIONAL AEROSPACE SAE AMS-QQ-P-416 - Plating, Cadmium (Electrodeposited) SAE AS5202 - Port or Fitting End, Internal Straight Thread, Design Standard (Copies of SAE documents are avai
13、lable from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001 or on-line at www.sae.org.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein (except for related spec
14、ification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Materials. 3.1.1 Nonmagnetic materials. Nonmagnetic materials shall be used for all parts of
15、 the gage except where magnetic materials are essential. 3.1.2 Nonferrous materials. Nonferrous materials shall be used for all parts of the gage except where ferrous materials are essential. 3.1.3 Metals. Metals shall be corrosion-resistant or suitably treated to resist corrosion due to fuels, salt
16、 fog, or atmospheric conditions likely to be met in storage or normal service. 3.1.4 Dissimilar metals. Unless suitably protected against electrolytic corrosion, dissimilar metals shall not be used in intimate contact with each other. Dissimilar metals are defined in MIL-STD-889. 3.1.5 Toxic and cor
17、rosive fumes. The gage shall be of such material and construction that fumes, when burned, or gases that combine with the atmosphere to form acid or corrosive alkali will not be liberated. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-25308
18、C 4 3.1.6 Protective treatment. When materials are used in the construction of the gage that are subject to deterioration when exposed to climatic and environmental conditions likely to occur during service usage, they shall be protected against such deterioration in a manner that will in no way pre
19、vent compliance with the requirements of this specification. The use of any protective coating that will crack, chip, or scale with age or extremes of climatic or environmental conditions shall be avoided. 3.1.7 Fungus proof materials. Materials that are nutrients for fungi shall not be used where i
20、t is practical to avoid them. Where used and not hermetically sealed, they shall be treated with a fungicidal agent acceptable to the procuring activity. 3.2 Design and construction. The gage shall be designed to indicate directly the pressure in aircraft hydraulic and pneumatic systems. The gage sh
21、all be so constructed that no parts will work loose in service and shall be built to withstand the strains, jars, vibrations and other conditions incident to shipment, storage, installation and service. 3.2.1 Pivots, bearings and gears. Pivots, bearings and gears shall neither bind nor shake and sha
22、ll be as frictionless as practicable. 3.2.2 Adjustment mechanism. When the gage is so designed as to permit adjustment, it shall be provided with a means for adjusting or correcting the indications which shall be simple to manipulate and so designed that adjustments can be made without the use of sp
23、ecial tools. The means of adjustment need not be outside the case. 3.2.3 Separate mechanism. The gage mechanism shall be comprised of units distinct from the case. The gage shall be sufficiently rugged that small distortions of the case will not affect accuracy of the indication. 3.2.4 Reliability.
24、The gage shall have a minimum acceptable mean-time-between-failures (MTBF) of 2,000 hours based upon a discrimination ratio of 1.5 and a confidence factor of 90 percent. 3.3 Performance. The gage shall operate satisfactorily after subjection to the following conditions: a. Temperatures operating tem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL25308C2010GAGEPRESSUREDIALINDICATINGHYDRAULICTYPEME1PDF

链接地址:http://www.mydoc123.com/p-690244.html