1、 AMSC N/A FSC 6145 INCH-POUND MIL-DTL-25038J 10 January 2012 SUPERSEDING MIL-DTL-25038H 9 September 2005 DETAIL SPECIFICATION WIRE, ELECTRICAL, HIGH TEMPERATURE, FIRE RESISTANT, AND FLIGHT CRITICAL This specification is approved for use by all Departments and Agencies of the Department of Defense. 1
2、. SCOPE 1.1 Scope. This specification covers insulated single wire for electrical use in flight critical circuits and under short-time emergency conditions involving exposure to flames with temperatures up to 2,000 F (see 6.1). 1.2 Part or Identifying Number (PIN). The PIN (see 6.2) consists of the
3、letter “M”, which indicates a defense specification item; the basic number of the specification sheet; and a coded number, as shown in the following example: M25038/1 - 22 1/- 9 - A2/Defense specification Wire size Color - Flight critical sheet (see 1.2.1) (see 1.2.2) 1/ For MIL-DTL-25038/3, the hea
4、vier wall construction has an “H” designator added to the PIN. 2/ Only for flight critical applications. 1.2.1 Wire size. The wire size is identified by a number indicating the conductor wire size (AWG). Comments, suggestions, or questions on this document should be addressed to DLA Land and Maritim
5、e, ATTN: VAI, P.O. Box 3990, Columbus, OH 43218-3990, or email to WireCabledla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or ne
6、tworking permitted without license from IHS-,-,-MIL-DTL-25038J 2 1.2.2 Color. The insulation color is identified by a series of numbers. The first number is the color of the insulation; the second number represents the color of the first stripe or band; the third number, the color of the second stri
7、pe or band, and so on. The colors and their corresponding numbers are shown in table I. TABLE I. Color code. Number designator Color Number designator Color 0 Black 5 Green 1 Brown 6 Blue 2 Red 7 Violet (purple) 3 Orange 8 Gray (slate) 4 Yellow 9 White 2. APPLICABLE DOCUMENTS 2.1 General. The docume
8、nts listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this l
9、ist, document users are cautioned that they must meet all specified requirements documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards and handbooks. The following specifications, standards and handbook
10、s form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). FEDERAL STANDARD FED-STD-228 - Cable and Wire, Insulated; Methods of Testing DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PR
11、F-5606 - Hydraulic Fluid, Petroleum Base: Aircraft, Missile, and Ordnance MIL-DTL-5624 - Turbine Fuel, Aviation, Grades JP-4 and JP-5 MIL-PRF-7808 - Lubricating Oil, Aircraft Turbine Engine, Synthetic Base MIL-DTL-12468 - Decontaminating Agent, STB MIL-PRF-23699 - Lubricating Oil, Aircraft Turbine E
12、ngine, Synthetic Base, NATO Code O-156 MIL-DTL-25038/1 - Wire, Electrical, High Temperature, Fire Resistant, Flight Critical, Normal Weight MIL-DTL-25038/3 - Wire, Electrical, High Temperature, Fire Resistant, Flight Critical, Light Weight, Small Diameter Provided by IHSNot for ResaleNo reproduction
13、 or networking permitted without license from IHS-,-,-MIL-DTL-25038J 3 MIL-DTL-83133 - Turbine Fuels, Aviation, Kerosene Types, NATO F-34(JP-8), NATO F-35, and JP-8 + 100 DEPARTMENT OF DEFENSE STANDARDS MIL-STD-104 - Limits for Electrical Insulation Color MIL-STD-2223 - Insulated Electrical Wire, Te
14、st Methods for (Copies of these documents are available online at https:/assist.daps.dla.mil or from the Standardization Document Order Desk, Building 4/D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the e
15、xtent specified herein. Unless otherwise specified, the documents are the issues of the documents of the documents cited in the solicitation or contract (see 6.2). ASTM INTERNATIONAL ASTM B263 - Standard Method for Determination of Cross-Sectional Area of Stranded Conductors ASTM B355 - Standard Spe
16、cification for Nickel-Coated Soft or Annealed Copper Wire ASTM B624 - Standard Specification for High Strength, High Conductivity, Copper-Alloy Wire for Electronic Application ASTM D910 - Standard Specification for Aviation Gasolines (Copies of these documents are available online at http:/www.astm.
17、org or from ASTM International, P.O. Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.) NCSL INTERNATIONAL NCSL Z540.3 - Calibration Laboratories and Measuring and Test Equipment, General Requirements (Copies of this document are available from http:/www.ncsli.org or from NCSL Inter
18、national, 2995 Wilderness Place, Suite 107, Boulder, CO 80381-5404.) NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) NEMA-WC 56 - 3.0 kHz Insulation Continuity Proof Testing for Wire and Cable (Copies of this document are available from http:/www.nema.org or from the National Electrical Manufac
19、turers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-25038J 4 SAE INTERNATIONAL SAE J1966 - Lubricating Oil, Aircraft Piston Engine (Nondispersant Mineral Oil) SAE AS1241
20、- Fire Resistant Phosphate Ester Hydraulic Fluid for Aircraft (Copies of these documents are available online at from http:/www.sae.org or from the SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) 2.4 Order of precedence. In the event of a conflict between the text of this docu
21、ment and the references cited herein, (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Specification sheets. The indi
22、vidual item requirements shall be as specified herein and in accordance with the applicable specification sheets. In the event of any conflict between requirements of this specification and the specification sheet, the latter shall govern. 3.2 Qualification. Wires furnished under this specification
23、shall be products that are authorized by the qualifying activity for listing on the applicable qualified products list before contract award (see 6.6). 3.3 Materials. 3.3.1 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials shou
24、ld be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life-cycle costs. 3.3.2 Conductor material. Strands used in the manufacture of conductors shall be in accordance with ASTM B355,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL25038J2012WIREELECTRICALHIGHTEMPERATUREFIRERESISTANTANDFLIGHTCRITICALPDF

链接地址:http://www.mydoc123.com/p-690241.html