《DLA DSCC-DWG-04047 REV C-2010 WIRE ELECTRICAL COMPOSITE POLYTETRAFLUOROETHYLENE POLYIMIDE INSULATED 30 28 26 AWG 600 VOLT.pdf》由会员分享,可在线阅读,更多相关《DLA DSCC-DWG-04047 REV C-2010 WIRE ELECTRICAL COMPOSITE POLYTETRAFLUOROETHYLENE POLYIMIDE INSULATED 30 28 26 AWG 600 VOLT.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、REVISIONS LTR DESCRIPTION DATE APPROVED A Technical revisions to be consistent with SAE-AS22759. Editorial changes throughout. 7/16/07 Abdo Abdouni B Added approved supplier. Technical changes throughout. Updated format. 30 March 2009 Abdo Abdouni C Added approved supplier. 8 September 2010 Abdo Abd
2、ouni Prepared in accordance with ASME Y14.100 Selected item drawing REV PAGE REV STATUS OF PAGES REV C B B B B B B B B B B B B C PAGE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC PREPARED BY DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 William Carpenter Original date of drawing 12 July 2004 CH
3、ECKED BY TITLE Lee Surowiec WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, 30, 28, 26 AWG, 600 VOLT APPROVED BY Richard L. Taylor SIZE CAGE CODE DWG. NO. 04047 A 037Z3 REV C PAGE 1 OF 14 AMSC N/A 6145-E097-010 .CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 HAS CHANGED NAMES TO:
4、DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 04047 REV B PAGE 2 FP Fluorocarbon Polymer, modified Polytetrafluor
5、oethylene (PTFE) FIGURE 1. General configuration. 1 SCOPE 1.1 Scope. This drawing covers the performance characteristics for 30, 28, 26 AWG light weight composite wire using a seamless polytetrafluoroethylene/hydrolysis resistant polyimide tape wrap insulation system. 1.2 Part or Identifying Number
6、(PIN). The complete PIN should be as specified on the requirements drawing and constructed using the following format: 04047 - 30 A - 9 Insulation color designator (see 1.2.2) Wire size (see table I) DSCC drawing number Conductor designator (see table II) CONDUCTOR, STRANDED, SMALL DIAMETER, SILVER,
7、 NICKEL, OR TIN PLATED COPPER FP / POLYIMIDE / FP TAPE FP TAPE Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 04047 REV B PAGE 3 TABLE I. Details of construction.
8、 PIN. Wire size Conductor Finished wire Stranding (number of strands X AWG gauge of strands) Diameter (in.) Resistance at 20C (68F) ohms/1000ft. (max) Diameter (in.) Weight lb/1000ft. (max) Min Max Min Max 04047-30A-* 30 7 X 38 .0110 .0130 117.4 .022 .026 0.75 04047-28A-* 28 7 X 36 .0140 .0160 74.4
9、.025 .029 1.00 04047-26A-* 26 19 X 38 .0175 .0204 44.8 .030 .034 1.43 * The asterisks in the PIN column of table I should be replaced by color code designators (see 1.2.2). Example: 04047-26-93 is white with an orange stripe. 1.2.2 Color. The color of the finished wire should be as indicated by the
10、insulation color designator (see 1.2) of the wire part number and the color specified in the contract or order. The first digit of the designator should indicate the colors of the stripes, bands, or tracers. The insulation color designator of the wire should be listed in MIL-STD-681, system I (diffe
11、rentiation color coding for chassis wiring). The preferred color and any applicable restrictions on available colors are indicated in the individual specification sheet. The color of the background insulation and the colors of any stripes, bands, or tracers, if used, should be in accordance with MIL
12、-STD-104, class I or table VI for laser marked wires. The color of the background, stripes or bands should be in accordance with MIL-STD-681 and should be capable of withstanding the durability (3.5.9) or color marking test (3.5.12) using the number of strokes and the weight specified herein (see 3.
13、7). 1.2.3 Conductor designators. Conductor designators should be as specified in table II. TABLE II. Conductor designator/temperature rating. 1/ Designator Conductor description Temperature rating A Silver plated copper alloy (SPA) 200C B Nickel plated copper alloy (NPA) 260C C Tin plated copper (TP
14、C) 150C D Silver plated copper (SPC) 200C E Nickel plated copper (NPC) 260C 1/ For a complete description of conductor material see 3.3.1 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a pa
15、rt of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-104 - Limits for Electrical Insulation Color MIL-STD-202 - Test Method Standard Electronic and Electr
16、ical Component Parts MIL-STD-2223 - Test Methods for Insulated Electric Wire (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Non-government publica
17、tions. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEF
18、ENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 04047 REV B PAGE 4 ASTM INTERNATIONAL ASTM B33 - Standard Specification for Tin Coated Soft or Annealed Copper Wire for Electrical Purposes ASTM B298 - Standard Specification for Silver Coated Soft or Annealed Copper
19、 Wire for Electronic Purposes ASTM B355 - Standard Specification for Nickel Coated Soft or Annealed Copper Wire ASTM B624 - Standard Specification for High Strength, High Conductivity Copper Alloy Wire for Electronic Application ASTM D3032 - Standard Test Methods for Hookup Wire Insulation ASTM D459
20、1 - Standard Test Method for Determining Temperatures and Heats of Transitions of Fluoropolymers by Differential Scanning Calorimetry (Copies of these documents are available from http:/www.astm.org/ or ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, Pennsylvania, USA 1942
21、8-2959.) NCSL INTERNATIONAL NCSL-Z540.3 - General Requirements for Calibration of Measuring and Test Equipment (Copies of these documents are available from http:/www.ncsli.org or to National Conference of Standards Laboratories (NCSL), 2995 Wilderness Place, Suite 107, Boulder, CO 80301-5404.) NATI
22、ONAL ELECTRICAL MANUFACTURERS ASSOCIATION NEMA WC 52 - High-Temperature and Electronic Insulated Wire - Impulse Dielectric Testing (Copies of these documents are available from http:/www.nema.org/ or .NEMA, 1300 North 17thStreet, Suite 1847, Rosslyn, VA 22209-3801). SAE INTERNATIONAL SAE-AS4373 - Te
23、st Methods for Insulated Electric Wire SAE-AS22759 - Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy SAE-AS22759/80 - Wire, Electrical, Polytetrafluoroethylene/polyimide Insulated, Light Weight, Tin Coated, Copper Conductor, 150 deg. C, 600 volts SAE-AS22759/81 - Wire, Electrical,
24、Polytetrafluoroethylene/polyimide Insulated, Light Weight, Silver Coated, High Strength or Ultra High Strength Copper Alloy, 200C, 600 Volts SAE-AS22759/82 - Wire, Electrical, Polytetrafluoroethylene/polyimide Insulated, Light Weight, Nickel Coated, High Strength or Ultra High Strength Copper Alloy,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG04047REVC2010WIREELECTRICALCOMPOSITEPOLYTETRAFLUOROETHYLENEPOLYIMIDEINSULATED302826AWG600VOLTPDF

链接地址:http://www.mydoc123.com/p-688593.html