1、AMSC N/A FSC 4940 A-A-59436A 5 October 2011 SUPERSEDING A-A-59436 17 September 1999 COMMERCIAL ITEM DESCRIPTION SEPARATORS, OIL AND WATER, COMPRESSED AIR, WALL MOUNTED The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. T
2、his commercial item description (CID) covers the general requirements for separators, oil and water, compressed air, wall mounted. Separators, oil and water, compressed air, wall mounted covered by this CID are intended for commercial/industrial applications. 2. CLASSIFICATION/PART IDENTIFICATION NU
3、MBER (PIN). This CID uses a classification system which is included in the PIN as shown in the following example (see 7.1). A-A-59436 - 01 CID Number Example: PIN denotes A-A-59436-01 wall mounted oil water, class 1 (one regulator and two air outlets.) TABLE I. Class and configuration. Designator Cl
4、ass Separator configuration -01 Class I One regulator and two air outlets -02 Class II Two regulators and four air outlets Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data that may improve this document should be sent to: DLA Land and Maritime, ATTN: VAI
5、, P.O. Box 3990, Columbus OH 43218-3990, or email FluidFlowdla.mil. Since contact information can change you may want to verify the currency of the address information using the ASSIST Online database at https:/assist.daps.dla.mil/. INCH-POUND Class (see table I). Provided by IHSNot for ResaleNo rep
6、roduction or networking permitted without license from IHS-,-,-A-A-59436A 2 3. SALIENT CHARACTERISTICS 3.1 Interface and physical dimensions. Separators, oil and water, compressed air, wall mounted supplied to this CID shall be as specified herein. 3.2 Components. a. Class I separator shall be a hea
7、d, a filtering unit, a reservoir, a drain valve, a pressure regulator, a regulated air pressure gauge, at least one regulated filtered air outlet valve, an unregulated air pressure gauge, and one supply line pressure filtered air outlet valve with necessary fittings. b. Class II separator shall have
8、 two pressure regulators, two regulated air pressure gauges, one unregulated air pressure gauge, a minimum of four air outlet valves (at least two of which will be for regulated filtered air and at least one of which will be for supply line pressure, filtered air), and the necessary fittings. 3.2.1
9、Filtering unit. The filtering unit shall be made of corrosion-resistant material. The filter shall be the cleanable or replaceable type capable of removing 10 micron or finer particle contamination. 3.2.2 Separator reservoir. The reservoir shall be made of corrosion-resistant material, shall have at
10、 least a one third (1/3) pint capacity, and shall have a valve for removing collected oil and/or water. 3.2.3 Pressure gauges. The pressure gauges shall be in accordance with ANSI B40.100, accuracy grade B. 3.2.4 Inlet and outlet fittings. The separator shall be provided with a female air inlet with
11、 inch NPT thread. All outlet valves shall have -18 NPSH thread, with a tapered seat having a 60 angle included for a female connection. 3.3 Capacity and performance. The capacity and performance requirements stated herein apply to both class I and class II separators unless otherwise indicated. Thes
12、e requirements are summarized in table II. TABLE II. Components, capacity and performance requirements. Requirements Class I Class II Inlet air pressure - 200 psig maximum X X Working temperature - 160F maximum X X Filter element 10 microns X X Cleanable/replaceable filter X X Regulator(s) 1 2 Gauge
13、s 2 3 1/3 pint reservoir X X Drain Valve X X Air passage 20 CFM 60 psig X X Regulated filtered air outlets 1 2 Total number of air outlets 2 4 Inlet fitting inch NPT thread X X Outlet fitting -18NPSH thread X X Corrosion resistant materials X X Provided by IHSNot for ResaleNo reproduction or network
14、ing permitted without license from IHS-,-,-A-A-59436A 3 3.3.1 Class I separator. With an inlet pressure of 100 pound-force per square inch gauge (psig) and regulated pressure of 60 psig, the regulated air pressure gauge shall record a drop of not more than 11 psig when the regulated air outlet valve
15、 is opened to permit air passage at a rate of 20 cubic feet per minute (CFM) free air, for a period of 30 seconds. With the inlet and regulated pressures as stated above, the regulated air pressure gauge shall record a drop of not more than 6 psig when the regulated air outlet valve is opened to per
16、mit air passage at the rate of 11 CFM free air for a period of 30 seconds. 3.3.2 Class II separator. The performance requirements for the class II separator shall be the same as the requirements for the class I separator (3.2.1 above) except that the requirements shall apply to the two regulators, i
17、ndividually, while being operated simultaneously. 3.3.3 Working pressures. The separator assembly and its component parts shall be suitable for use with a maximum working pressure of 200 psig, at a maximum operating temperature of +160F. Each pressure regulator shall be adjustable for delivery of ai
18、r at any pressure from not less than 20 to 100 psig. The differential pressure shall not be more than 5 psig from inlet to outlet over the range of regulation. 3.3.4 Safety and health requirements. The separators shall comply with the general safety and health requirements promulgated under Title 29
19、, Code for Federal Regulations (CFR) Chapter XVII, Part 1910 (http:/www.osha.gov/), which are applicable to the separators themselves. 3.3.5 Protective plugs and caps. Protective plugs and caps shall be installed in the ports and over the threaded connections to prevent damage. 3.4 Marking. Separato
20、rs, oil and water, compressed air, wall mounted supplied to this CID shall be marked with the manufacturers (MFRs) standard commercial PIN. The PIN marked on the unit pack shall be the CID PIN. 3.5 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA59436A2011SEPARATORSOILANDWATERCOMPRESSEDAIRWALLMOUNTEDPDF

链接地址:http://www.mydoc123.com/p-687383.html