DLA A-A-59252-1998 ETCHERS ELECTRIC PORTABLE 120-VOLT A C [Superseded NAVY MIL-E-3118 C CANC NOTICE 2 NAVY MIL-E-3118 C VALID NOTICE 1 NAVY MIL-E-3118 C (1) NAVY MIL-E-3118 C NAVY .pdf
《DLA A-A-59252-1998 ETCHERS ELECTRIC PORTABLE 120-VOLT A C [Superseded NAVY MIL-E-3118 C CANC NOTICE 2 NAVY MIL-E-3118 C VALID NOTICE 1 NAVY MIL-E-3118 C (1) NAVY MIL-E-3118 C NAVY .pdf》由会员分享,可在线阅读,更多相关《DLA A-A-59252-1998 ETCHERS ELECTRIC PORTABLE 120-VOLT A C [Superseded NAVY MIL-E-3118 C CANC NOTICE 2 NAVY MIL-E-3118 C VALID NOTICE 1 NAVY MIL-E-3118 C (1) NAVY MIL-E-3118 C NAVY .pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、a INCH-POUND A-A-5 9252 June 16.1998 SUPERSEDING 12Februa1y 1974 MIL-E-3 1 18C COMMERCIAL ITEM DESCRIPTION ETCHERS, ELECTRIC, PORTABLE, 120-VOLT A.C. The General Services Administration has authorized the use of this commercial item description for ail Federal agencies. 1. SCOPE. This commercial ite
2、m description (CID) covers electric etchers of electric arc and vibrating point type. 2. CLASSIFICATION. Electric etchers covered by this CID are of the following types as specified (see 7.2). Type I - Light duty etcher, 500 watts. Type II - Heavy duty etcher, 1,000 watts. Type III - Heavy duty etch
3、er, vibrating type. 3. SALIENT CHARACTERISTICS. 3.1 Description. Type I and II etchers shall consist of a case, transformer, control panel, power ?on-off switch, power cable with plug, etching tool lead, etching tool or stylus, ground clamp, and a ground plate when funiished. Type I etchers shall co
4、nsist of a drive unit, reciprocating shafl, collet or chuck, switch, power cable, and replaceable etching points. Etchers shall operate on 120 volts (rated voltage), 50 to 60 Hertz, alternating current (AC). Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any dat
5、a which may improve this document should be sent to: officer In Charge (Code 15E2), Seabee Logistics Center, 41 11 San Pedro St., Port Hueneme, CA 930434410, by using the Standardization Document Improvement Proposai (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 513
6、0 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59252 = 90L054 0000600 Ob3 m A-A-5 9252 3.2 Standard commercial product. The etchen shall, as a minimum be in accordance with this CID and shall be the manufiadurers standard commercial product. A
7、dditional or better features which are not specifically prohibited by this CID but which are a part of the manufacturers standard commercial product, shall be included in the etchers being furnished. A standard commercial product is a product which has been sold or is being currently offered for sal
8、e on the commercial market through advertisements or manufacturers catalogs, or brochures, and represents the latest production model. 3.3 Desim. The etcher shall be designed to etch on metals by the electric-arc process for types I and II and vibratov-scariEyrng process for type III. 3.3.1 Insulati
9、on resistance. Insulation of the etcher shall be dielehc. 3.3.2 Plugs. Plugs on etcher power cables shall be rated at not less than 15 amperes, 125 volts. 3.3.3 Fastening devices. All screws, pins, bolts, and similar parts shall be installed with means of preventing loss of tightness. All such parts
10、, when subject to removal or adjustment, shall not be swaged, peened, staked, or permanently deformed. 3.3.4 Power cable. The power cable for etchers shall be not less than 5-foot (1 524 millimetre (mm) lengh of commercial type, threeanductor cable of suitable size. The cable shail be equipped with
11、the plug specified in 3.3.2. The length of cable shall be measured from the point of entry into the tool. 3.3.5 Types I and II. 3.3.5.1 Heat output. Type I and II etchers shall be capable of operating for 30 minutes at heat output of 500 to 1,000 watts respectively in “oI and “off duty cycles. The t
12、ransformer temperature shall be not greater than 149 degrees Fahrenheit (OF) (65 degrees Celsius (OC) above ambient. The etching point shall withstand the heat developed without distortion or blunting of the tip. Type I shall have not less than 3 heat-taps. Type II. shall have not less than 10 heat-
13、taps with not less than three taps below 300 watts. 3.3.5.2 Weight. The weight of type I and II etchers shall be not greater than 25 and 3 5 pounds (1 1.34 and 15.88 kilogram (kg), respectively. 3.3.5.3 Case. The case of type I and II etchers shall be made of sheet steel. The base of the case shall
14、have five embossed dimples of not less than 0.375-inch (9.53 mm) spherical radius that shall raise the inside base of the etcher case. Alternatively, rubber pads of not less than 0.875-inch (22.23 mm) diameter by 0.375-inch (9.53 mm) thick may be substituted for the dimples. The pads shall be aached
15、 with locked screws. The case shall be equipped with a handle with a hand grip. Space shail be provided within the case for stowage of the power cable, etching tool with spare points, etching point and ground leads, and a pund plate when furnished. Altematively, an integral part of the case, suitabl
16、e for use as a ground for the etching tool, may be substituted for the ground plate (see 3.3.5.8). 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- A-A-59252 9038054 O000603 TTT A-A-5 9252 3.3.5.4 Transformer. The transformer shall be designed for
17、the duty specified herein on a rated input voltage of not less than 120-volts AC, without creating a fire hazard. The transfomer shall be mounted rigidly and securely in the etcher case so that the transformer shall not become loosened or detached from its mounting. The use of an adhesive for mounti
18、ng shall not be acceptable. 3.3.5.5 Control panel. The control panel shall have an indicator light to indicate when power is on, two output terminal studs, an “on” and “off power switch, and a rotary heat-tap selector with a pointer and legible dial for indicating the applicable heat-taps (see 3.3.5
19、.1). The output terminals shall be insulated to prevent any grounding through the hole cross sectional and panel surface areas. 3.3.5.6 Etching tool and ground leads. Etching tool and ground leads shall be not less than 3-foot (914.40 mm) length of suitable size of insulated wire cable. Each lead sh
20、all be equipped with a spade-type copper terminai at one end for connection to the transformer terminal studs. An etching tool shall be attached to the other end of the etching tool lead and a positive-type grounding copper terminal shall be attached to the other end of the ground lead. 3.3.5.7 Etch
21、ing tool. The etching tool or stylus shall have an insulated holder of suitable size and shape for ease of handling and a replaceable etching point. The tool shall be provided with a spare etching point. 3.3.5.8 Ground plate. The ground plate of type I and II etchers, when furnished, shall provide e
22、lectrical conductivity and have not less than a 25 square inch (16 129 square millimetre) surface area. 3.3.5.9 Graund clamp. The ground clamp of type I and II etchers, when furnished, shall provide electrical conductivity for etching large parts that cannot be conveniently placed on the ground plat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA592521998ETCHERSELECTRICPORTABLE120VOLTACSUPERSEDEDNAVYMILE3118CCANCNOTICE2NAVYMILE3118CVALIDNOTICE1NAVYMILE3118C1NAVYMILE3118CNAVYPDF

链接地址:http://www.mydoc123.com/p-687199.html