DLA A-A-55134 A-2013 LIGHT CHEMILUMINESCENT 6 IN 12 HOUR B C E F.pdf
《DLA A-A-55134 A-2013 LIGHT CHEMILUMINESCENT 6 IN 12 HOUR B C E F.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-55134 A-2013 LIGHT CHEMILUMINESCENT 6 IN 12 HOUR B C E F.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: STDZNMGTdla.mil or Defense Logistics Agency - Aviation ATTN: VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5610. Since contact information can chang
2、e, you may want to verify the currency of this address information using the ASSIST database at https:/assist.dla.mil. FSC 6260 INCH-POUND A-A-55134A 16 September 2013 SUPERSEDING A-A-55134 10 December 1992 COMMERCIAL ITEM DESCRIPTION LIGHT, CHEMILUMINESCENT, 6 IN 12 HOUR B, C, E, F The General Serv
3、ices Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. This commercial item description (CID) covers 12 hour 6 inch chemiluminescent lights (commonly known as a light stick) used for a variety of lighting, marking, and identification purpos
4、es. 2. CLASSIFICATION. These chemiluminescent lights shall be of the following colors letter as specified and shall be identified in the Part Identification Number (PIN) paragraph (see 7.2) Color B = Green Color C = Orange Color E = Red Color F = Yellow 3. SALIENT CHARACTERISTICS. 3.1 Design. The ch
5、emiluminescent light shall be elongated having an overall length of 152.4mm (6 inches) plus 2.54mm (0.100 inches) minus 9.5mm (0.375 inches.) The midpoint diameter shall be no less than 12.7mm (.500 inches) and the light stick shall have a flat base on one end. The diameter of the flat end shall not
6、 exceed 19.1mm (.750 inches). The endopposite the flat base shall have a hole 4.78mm (.188 inches) nominal. Light sticks shall have a tapered shape and shall be compatible with items in TABLE III. 3.1.1 Fluid Level. The vertical fluid level, when measured from the exterior of the flat base shall be
7、no less than 82 mm (3.250 inches.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55134A 2 3.2 Interior. The chemiluminescent lights specified in this CID shall produce a level of light intensity as specified in Table I for a specified length of
8、 time (12 hours). In addition the chromaticity of the emitted light shall meet the requirements in Table II. TABLE I. Light Intensity vs. Time (Minimum Requirements) TABLE II. 1931 CIE Chromaticity Diagram Coordinates 3.3 Test criteria. Illuminance shall meet or exceed the data presented in Table I.
9、 Activated by manually flexing the plastic tube, breaking the inner vial and shaking to combine components. Plastic tube shall not leak and vial will not break when subjected to an external pressure equivalent to 9,144m (30,000 feet) at 24o C (75o F) in a vacuum chamber. It shall withstand a free fa
10、ll; while still in wrapper from a height of 2.6 meters (8.5 feet) on a hard surface (i.e. concrete) without activating or leakage. 15 Min 1 Hour 2 Hour 3 Hour 4 Hour 5 Hour 6 Hour 8 Hour 10 Hour 12 Hour Green 32.93 25.00 20.00 15.00 11.50 8.00 5.00 2.70 1.20 0.60 Yellow 38.00 25.50 20.00 15.50 12.10
11、 9.30 7.20 4.50 2.50 1.50 Red 10.00 6.50 4.80 3.70 3.00 2.50 1.80 1.30 0.70 0.50 Orange 19.00 14.00 10.50 7.60 6.00 4.50 2.75 1.70 0.90 0.40 NOTES: 1. Unit of measure: Lumens per square meter. 2. All tests shall be conducted at 24oC 1oC (75.2 2F) Green X Coordinate 0.2164 0.2830 Y Coordinate 0.6536
12、0.6578 Yellow X Coordinate 0.4790 0.4910 Y Coordinate 0.5040 0.5139 Red X Coordinate 0.6462 0.6681 Y Coordinate 0.3336 0.3458 Orange X Coordinate 0.5927 0.6068 Y Coordinate 0.3784 0.3939 NOTES: 1. 1931 CIE Chromaticity Diagram Coordinates measured using a Topcon BM-7-232/AL-6 Colorimeter with a clos
13、e-up lens. The values on Table II identify the point that represents the shade of color for the Green, Yellow, Red, and Orange. 2. Coordinate measurements shall meet the following criteria measured 10 minutes after activation at 24C 1 C. (75.2 2F) Provided by IHSNot for ResaleNo reproduction or netw
14、orking permitted without license from IHS-,-,-A-A-55134A 3 3.3.1 Test conditions. a. Meter: Radiometer, International Light Model IL1700, Sensor probe SED 033Y filter. All meters shall be traceable to NIST. b. Light stick to IL1700 probe distance: 22 0.5 mm (0.866 0.02 inches) c. Temperature Stabili
15、zation: Light sticks will be placed in a water bath at test temperature 24oC 1oC (75.2 2F) for a minimum of one (1) hour before activation. d. Activation method: Bend; agitate for ten (10) seconds. e. Light sticks shall be agitated for ten (10) seconds before each reading. f. Light sticks shall keep
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA55134A2013LIGHTCHEMILUMINESCENT6IN12HOURBCEFPDF

链接地址:http://www.mydoc123.com/p-686537.html