1、A-A-55133 m 9999974 0320787 767 m Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be sent to: Commander, Space and Naval Warfare Command, ATTN: SPAWAR 003-114/031, Washington, DC 20363. INCH-POUND A-A- 5 5 13 3 Dec
2、ember 10, 1992 COMMERCIAL ITEM DESCRIPTION LIGHT, CHEMILUMINESCENT, 6-IN - 30 MIN - G The General Services Administration has authorized the use of this commercial item description. Abstract. This description covers a 30 minute 6 inch chemiluminescent light (commonly known as a light wand) used for
3、a variety of lighting, marking, and identification purposes. Salient characteristics. 1. Color. The color of the chemiluminescent light described in this CID is white. The color wand required shall be identified in the Part Identification Number (PIN) paragraph of this CID. AMSC N/A FSC 6260 DISTRIB
4、UTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55 13 3 2. Desisn. The chemiluminescent light shall be elongated having an overall length of 6 inches plus 0.043 minus 0.37
5、5 inches. The mid point diameter shall be no less than .500 inches and the wand shall have a flat base on one end. The diameter of the flat end shall not exceed .750 inches. The end opposite the flat base shall have a hole .188 inches nominal. Lightsticks shall have a tapered shape and shall be comp
6、atible with accessory items; Lightstick Shield (NSN 6260-01-196-0637), Ground Stake (NSN 6260-01-230-8555), Flare, Surface Trip (NSN 6260-01-247-2937), Handle, six (6) inch (NSN 6260-01-255-3345), and Magnetic Base (NSN 6260-01-255-3346). Lightsticks shall be individually wrapped in an airtight wrap
7、per. 3. Interior. The chemiluminescent light specified in this Commercial Item Description shall produce a level of light intensity as specified in Table I for a specified length of time (30 minutes). 4. Material Safety Data Sheet. Manufacturer shall provide evidence in the form of a Material Safety
8、 Data Sheet (MSDS) (Fed-Std-313) that the components shall not be highly toxic, toxic, corrosive or irritant in terms of the definitions and tests in Code of Federal Regulations, Title 16, Part 1500 (Federal Hazardous Substances Act). 5. Test criteria. Illuminance must meet or exceed the data presen
9、ted in Table I. The integrated luminance over 15 minutes starting at 5 seconds after activation measured at 75 degrees F on lightsticks a minimum of 30 days after manufacture, but not more than 90 days, must meet or exceed 12.60 foot lambert-hours - Color G (white). After Ageing Test, illuminance mu
10、st meet or exceed data in Table II. breaking the inner vial and shaking to combine components. tube shall not leak and vial will not break when subjected to an external pressure equivalent to 30,000 feet at 75 degrees F in a vacuum chamber. Must withstand, while still in wrapper, a free fall from a
11、height of 8.5 feet on a hard surface (concrete) without activating or leakage. Activated by manually flexing the plastic tube, Plastic 6. Test conditions. a. Meter: Digital Photometer, TEKTRONIX, Model J16, Sensor Probe J6501. All meters traceable to NIST. b. Wand to Tektronix J16 Meter Distance: 1.
12、50 inches 2 0.02 inches. Wand to Luminance Meter Distance: 12 inches c. Temperature stabilization: Wands while still in sealed foil wrappers, will be placed in a water bath test temperature for a minimum of one (1) hour before activation for the 75 F test temperature and for a minimum of two (2) hou
13、rs for the 32 F test temperature. d. activation. Remove wand from sealed foil wr.apper immediately before Light wand shall be handled by cap end during testing. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55133 W 9999974 0320789 53T W - A-A
14、-5 5 13 3 e. Activation method: Bend; agitate for ten (10) seconds. f. Wands shall be agitated for ten (10) seconds before each reading. O g. Wands kept under cover or in darkness; may be exposed to light during movement to and from light meter. h. All meter readings made in darkness. i. Meter kept
15、at 75 degrees F for all tests. j. Temperature tolerances: plus or minus 2 F. . k. Holder, wand test fixture in accordance with DGSC drawing, DGSCV-91-03, Part Number 3. (Enclosure 1) 1. Chemiluminescent lights shall be held in a vertical position with cap end down when light output measurement is ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA551331992LIGHTCHEMILUMINESCENT6IN30MING6IN30MING 化学 发光 PDF

链接地址:http://www.mydoc123.com/p-686536.html