《DIN EN ISO 25745-1-2013 Energy performance of lifts escalators and moving walks - Part 1 Energy measurement and verification (ISO 25745-1 2012) German version EN ISO 25745-1 2012《升.pdf》由会员分享,可在线阅读,更多相关《DIN EN ISO 25745-1-2013 Energy performance of lifts escalators and moving walks - Part 1 Energy measurement and verification (ISO 25745-1 2012) German version EN ISO 25745-1 2012《升.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、February 2013 Translation by DIN-Sprachendienst.English price group 12No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).I
2、CS 91.140.90!$R speed in the direction of the moving steps or pallets when operating the equipment in the no load condition (i.e. without persons), stated by the manufacturer as that for which the escalator has been designed2.12.2nominal speedspeed in the direction of the belt when operating the equ
3、ipment in the no load condition (i.e. without persons), stated by the manufacturer as that for which the moving walk has been designedDIN EN ISO 25745-1:2013-02 EN ISO 25745-1:2012 (E) 62.13reference cyclecycle during which the empty car is run from the bottom terminal landing, to the top terminal l
4、anding, and then back to the bottom terminal landing including two complete door cycles2.14running currentcurrent drawn by the lift, when it has achieved rated speed in either the up or down direction2.15slow speed conditioncondition when an escalator or moving walk is running at slow speed without
5、passengers2.16 Standby conditionNOTE 1 For units with power back-up systems, the lift, escalator or moving walk should be connected and operating on main power with back up power outputs disabled while the measurements are taken.NOTE 2 Care should be taken to ensure that the application of the stand
6、by condition does not compromise the safety of the installation.2.16.1standby conditioncondition when a lift is stationary at a floor and may have reduced the power consumption to a lower level set for that particular lift2.16.2standby conditioncondition when the escalator/ or moving walk is station
7、ary and powered on and can be started by authorized personnelNOTE There may be other electrical loads not associated with the escalator or moving walk, which should not be included.2.17standby currentcurrent drawn by the lift, when in standby condition2.18terminal landings cycling testtest for lifts
8、 when the car is continuously cycled between the bottom terminal landing and the top terminal landing, with the door operations enabled and no load in the car2.19verificationprocedure to identify any significant changes in energy characteristics during the life of the lift, escalator or moving walk3
9、 Measurement and verification of lift, escalator and moving walk energy usage3.1 GeneralThis part of ISO 25745 specifies:a) an accurate method of energy measurement in order to confirm manufacturers declarations of energy usage;b) quick and simple procedure for measurements to identify any significa
10、nt changes in energy usage during the life of the installation.Measurements and verifications may be performed after commissioning, in-service and after modernization if required.DIN EN ISO 25745-1:2013-02 EN ISO 25745-1:2012 (E) 7 The measurements shall be: practical in the field; repeatable; able
11、to utilize commonly available measuring equipment; performed by a trained, competent person.Tables 1 and 2 summarize measurements to be made and the instrumentation required.Table 1 Lift measurement and verification of energy usageType of measurement Measurements to be made InstrumentationEnergy mea
12、surement (see 3.2 and 4.2)Main energy runningMain energy idle and standbyAncillary energy runningAncillary energy idle and standbyEnergy meter(see 4.1)Energy verification check (see 3.3.2 and 4.3)Main current runningMain current idle and standbyAncillary current runningAncillary current idle and sta
13、ndbyCurrent probe(see 4.1)Table 2 Escalator and moving walk measurement and verification of energy usageType of measurement Measurements to be made InstrumentationPower measurement (see 3.2 and 5.2)Power in standby conditionPower in autostart conditionPower in slow speed conditionPower in no load co
14、nditionAncillary powerPower meter(see 5.1)Energy verification check (see 3.3.3 and 5.3)Power in no load condition Power meter (see 5.1)NOTE No reference cycle is used for escalators and moving walks. Therefore a power measurement and power verification check is applied.3.2 Lift energy measurements o
15、r escalator and moving walk power measurementsThis measurement may be run on request after commissioning and at any point during the equipment life cycle as needed. The specification for the measurement system is indicated in 4.1 for lifts and 5.1 for escalators and moving walks.3.3 Lift, escalator
16、and moving walk energy verification check3.3.1 GeneralThis check is to verify that power usage of a unit has not significantly changed over the life of the installation by a quick, simple procedure.DIN EN ISO 25745-1:2013-02 EN ISO 25745-1:2012 (E) 83.3.2 LiftOnly the current is measured, as this is
17、 the most likely element of energy consumption to change with equipment ageing. Initially a current or a current profile is established after equipment commissioning and after modernization. Thereafter checks may be performed at any time during the operating life of equipment, to determine whether t
18、he energy consumption of the equipment has changed. The specification for the measurement system is indicated in 4.1.Usually aging affects the energy consumption when the lift is running. Therefore unless modifications have been made it should only be necessary to measure the main current running.3.
19、3.3 Escalator and moving walkInitially power in the no load condition is measured. Thereafter, periodic checks of power in the no load condition may be performed at any time during the operating life of equipment, to determine whether the energy consumption of the equipment has changed. The specific
20、ation for the measurement system is indicated in 5.1.3.4 Multiple lift, escalator and moving walk installationsIn the case of multiple lift, escalator and moving walk installations, each unit is tested as a standalone piece of equipment.NOTE It is important to note that a group of lifts can be more
21、energy efficient than single units operating alone.4 Measurement procedures for a lift installation4.1 Preliminaries4.1.1 InstrumentationThe measuring instrumentation shall comply with the following:a) an ammeter and voltmeter capable of measuring root mean square values;b) an energy meter capable o
22、f measuring energy with unbalanced loads.The energy meters can be those defined in IEC 620532or a power and energy analyser as defined in IEC 61000-4-301or any other equivalent instrument. It is important to ensure that the instruments selected are compatible with the technology of the installation,
23、 in particular for regenerative drives or where non sinusoidal wave-shapes may be present and supply systems where no neutral is provided.4.1.2 AccuracyThe measured value shall have accuracy of at least than 10 %.4.1.3 Test set upThe set up conditions shall be as follows.a) The instrument model numb
24、ers utilized for the test procedures shall be recorded.b) The tests shall be conducted without changing any lift parameters. The lift unit parameters (ID, location, etc.) shall be recorded for identification purposes.c) Public usage or entry to the lift shall be prevented and the terminal landing en
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINENISO2574512013ENERGYPERFORMANCEOFLIFTSESCALATORSANDMOVINGWALKSPART1ENERGYMEASUREMENTANDVERIFICATIONISO2574512012GERMANVERSIONENISO2574512012

链接地址:http://www.mydoc123.com/p-682707.html