DIN EN 16147-2011 Heat pumps with electrically driven compressors - Testing and requirements for marking of domestic hot water units German version EN 16147 2011《带电力驱动压缩机的热泵 家庭热水机组.pdf
《DIN EN 16147-2011 Heat pumps with electrically driven compressors - Testing and requirements for marking of domestic hot water units German version EN 16147 2011《带电力驱动压缩机的热泵 家庭热水机组.pdf》由会员分享,可在线阅读,更多相关《DIN EN 16147-2011 Heat pumps with electrically driven compressors - Testing and requirements for marking of domestic hot water units German version EN 16147 2011《带电力驱动压缩机的热泵 家庭热水机组.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、 One or more corrigenda exist with corrections to this document. These can be searched online and ordered free of charge at www.beuth.de April 2011 Translation by DIN-Sprachendienst.English price group 15No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut
2、fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 27.080!$ny%“1758602www.din.deDDIN EN 16147Heat pumps with electrically driven compressors Testing and requirements for marking of domestic hot water unitsEnglish t
3、ranslation of DIN EN 16147:2011-04Wrmepumpen mit elektrisch angetriebenen Verdichtern Prfungen und Anforderungen an die Kennzeichnung von Gerten zum Erwrmen vonBrauchwarmwasserEnglische bersetzung von DIN EN 16147:2011-04Pompes chaleur avec compresseur entran par moteur lectrique Essais et exigences
4、 pour le marquage des appareils pour eau chaude sanitaireTraduction anglaise de DIN EN 16147:2011-04SupersedesDIN EN 255-3:1997-07www.beuth.deDocument comprises pagesIn case of doubt, the German-language original shall be considered authoritative.03.11 37DIN EN 16147:2011-04 A comma is used as the d
5、ecimal marker. National foreword This standard has been prepared by Technical Committee CEN/TC 113 “Heat pumps and air conditioning units” (Secretariat: AENOR, Spain). The responsible German body involved in its preparation was the Normenausschuss Kltetechnik (Refrigeration Technology Standards Comm
6、ittee), Working Committee NA 044-00-06 AA Elektromotorisch angetriebene Wrmepumpen und Luftkonditionierungsgerte. Amendments This standard differs from DIN EN 255-3:1997-07 as follows: a) Clause 3 “Terms and definitions” has been revised; b) general test conditions have been modified; c) specificati
7、ons relating to the determination of the energy consumption have been added; d) specifications relating to the performance test (Clause 6) have been completely revised; e) the former Annex A “Types of sanitary hot water heat pumps” has been deleted. Previous editions DIN 8900-2: 1980-10 DIN 8900-3:
8、1982-09 DIN 8900-4: 1982-06 DIN EN 255-3: 1997-07 2 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16147 January 2011 ICS 27.080; 27.200 Supersedes EN 255-3:1997English Version Heat pumps with electrically driven compressors - Testing and requirements for marking of domestic hot water units Po
9、mpes chaleur avec compresseur entrain par moteur lectrique - Essais et exigences pour le marquage des appareils pour eau chaude sanitaire Wrmepumpen mit elektrisch angetriebenen Verdichtern - Prfungen und Anforderungen an die Kennzeichnung von Gerten zum Erwrmen von Brauchwarmwasser This European St
10、andard was approved by CEN on 3 December 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerni
11、ng such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into i
12、ts own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
13、 Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B
14、-1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16147:2011: EEN 16147:2011 (E) 2 Contents Page Foreword . 41 Scope . 52 Normative references . 53 Terms and definitions 54 Symbols and abbreviations . 65 General t
15、est requirements . 85.1 Test apparatus and uncertainties . 85.2 Test room for the outdoor heat exchanger of air source heat pumps 105.3 Setting the external static pressure difference on the air side for heat pumps with duct connection . 105.3.1 All units 105.3.2 Non ducted units. 105.3.3 Ducted uni
16、ts 115.4 Installation and connection of the heat pump . 115.5 Installation of heat pumps consisting of several parts 125.6 Test conditions . 126 Performance test and determination of the energy consumption . 136.1 General . 136.2 Basic principles, scope of the tests 136.3 Heating up period . 146.4 S
17、tandby power input 156.5 Useful energy, electricity consumption and COP by using reference tapping cycles 156.5.1 Reference tapping cycles 156.5.2 Determination of the daily useful energy . 216.5.3 Determination of the daily electricity consumption 236.5.4 Coefficient of performance (COPDHW) 256.6 R
18、eference hot water temperature and maximum volume of usable hot water 266.7 Temperature operating range 276.7.1 General . 276.7.2 Outside the operating range 286.8 Safety devices checking test . 286.8.1 General . 286.8.2 Shutting off the heat transfer medium flows . 286.8.3 Complete power supply fai
19、lure . 286.8.4 Condensate draining 297 Test results and test report . 297.1 Data to be recorded 297.2 Test report . 317.2.1 General information 317.2.2 Main results . 318 Marking 329 Documentation 329.1 Technical data sheet 329.1.1 General description 329.1.2 Performance characteristics . 329.2 Inst
20、ructions . 339.2.1 General . 339.2.2 Physical description . 33DIN EN 16147:2011-04 EN 16147:2011 (E) 3 9.2.3 Additional heating devices, if integrated in unit . 339.2.4 Control and safety 339.2.5 Instructions for installation . 339.2.6 Instructions for maintenance 34Bibliography . 35DIN EN 16147:201
21、1-04 EN 16147:2011 (E) 4 Foreword This document (EN 16147:2011) has been prepared by Technical Committee CEN/TC 113 “Heat pumps and air conditioning units”, the secretariat of which is held by AENOR. This European Standard shall be given the status of a national standard, either by publication of an
22、 identical text or by endorsement, at the latest by July 2011, and conflicting national standards shall be withdrawn at the latest by July 2011. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held
23、responsible for identifying any or all such patent rights. This document supersedes EN 255-3:1997. This European Standard has been prepared under a mandate M/324 given to CEN by the European Commission and the European Free Trade Association. This document has been prepared by the working group CEN/
24、TC 113/WG 10 “Heat pumps and air conditioners“. This standard was submitted to enquiry under the reference prEN 255-3 which has been changed before Formal Vote to FprEN 16147. This European Standard references the document TREN D1 D(2002) M/324 for information on “Water-Heaters, Hot Water Storage Ap
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN161472011HEATPUMPSWITHELECTRICALLYDRIVENCOMPRESSORSTESTINGANDREQUIREMENTSFORMARKINGOFDOMESTICHOTWATERUNITSGERMANVERSIONEN161472011

链接地址:http://www.mydoc123.com/p-672681.html