《DIN EN 16058-2012 Influence of metallic materials on water intended for human consumption - Dynamic rig test for assessment of surface coatings with nickel layers - Long-term test .pdf》由会员分享,可在线阅读,更多相关《DIN EN 16058-2012 Influence of metallic materials on water intended for human consumption - Dynamic rig test for assessment of surface coatings with nickel layers - Long-term test .pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、-XO7UDQVODWLRQE,16SUDFKHQGLHQVW(QJOLVKSULFHJURXS1RSDUWRIWKLVWUDQVODWLRQPDEHUHSURGXFHGZLWKRXWSULRUSHUPLVVLRQRI,1HXWVFKHV,QVWLWXWIU1RUPXQJH9%HUOLQ%HXWK9HUODJ*PE+%HUOLQ*HUPDQKDVWKHHFOXVLYHULJKWRIVDOHIRU*HUPDQ6WDQGDUGV ,11RUPHQ , analysis of nickel concentration in the stagnation water (see Clause 9). T
2、est lines shall not be emptied as a result of sampling. Water samples for the analysis of metals shall be acidified to a pH 2. Short term interruption (less than three days) of the flow regime due to maintenance or problems shall be permitted without invalidating the test. Water samples, however, sh
3、all not be taken within five days following restart. Any interruption in the test shall be reported in the test report (see Clause 11) together with a justification or explanation. 8.2 Test water sampling For the analysis of test water, samples shall be taken from the sampling point at the entry of
4、the test rig (see Annex A, Figure A.1. and Figure A.2) after flushing. 8.3 Sampling to determine metal release At weekly intervals, starting at the 3rdday of operation, water samples shall be taken in accordance with EN 15664-1:2008, from each test line after 4 h ( 5 min) stagnation time. DIN EN 160
5、58:2012-07 EN 16058:2012 (E) 9 During the sampling procedure the flow rate shall be (5 0,5) l/min (turbulent flow). 8.4 Sampling volumes For end point devices the volume of the representative water sample shall be the first (500 50) ml. For in-line devices the volume of the representative water samp
6、le shall be determined according to EN 15664-1:2008, 6.3. 9 Analysis Analyse the test water, contact water and control water using the measurement methods specified in EN 15664-1:2008, Table C.1. NOTE General guidance on analytical performance requirements such as detection limits and accuracy is co
7、ntained in ENV ISO 13530. 10 Expression of results 10.1 Nickel concentration calculation for end point devices For each individual test line (n) with end point devices, at every operating time (T), calculate the nickel concentration as follows: refnSCLnnVVTcTcTc,*)()()( =where )(*Tcnis the nickel co
8、ncentration per liter corrected by subtraction of blind value and normalized to a water sample volume of 1000 ml for line (n); )(Tcnis the nickel concentration in the water sample taken from the individual test line (n); )(TcCLis the nickel concentration in the water sample taken from the control li
9、ne CL; VS,nis the volume of the water sample in mL taken from test line n; Vrefis the reference volume of 1000 ml. For the condition: n: number of the test line (n=1, 2 , 3, 4 or 5) When )(TcCLis lower than the quantification limit of the analysis then: refnSnnVVTcTc,*)()( =. Any negative result sha
10、ll be reported as below quantification limit. DIN EN 16058:2012-07 EN 16058:2012 (E) 10 10.2 Nickel concentration calculation for in-line devices For each individual test line (n) with in-line devices, at every operating time (T), calculate the nickel concentration as follows: TSnSCLnnEPVVTcTcTc,*,)
11、()()( =where )(*,TcnEPis the equivalent pipe concentration corrected by subtraction of blind value for line (n); )(Tcnis the nickel concentration in the water sample taken from the individual test line (n); )(TcCLis the nickel concentration in the water sample taken from the control line CL; VS,n is
12、 the volume of the water sample taken from test line (n) in ml; VTSis the volume of the water in the test samples installed in the test line in ml. For the condition: n: number of the test line (n=1, 2 , 3, ) when )(TcCLis lower than the quantification limit of the analysis then TSnSnnEPVVTcTc,*,)()
13、( =. Any negative result shall be reported as below quantification limit. 10.3 Mean concentration after a given period of operation (T) Calculate the arithmetic mean and the standard deviation of the nickel concentrations of the different test lines. 10.4 Presentation of results The individual value
14、s shall be tabulated. For each test line, the nickel concentrations after 4h-stagnation according to 10.1 for end point devices or 10.2 for in-line devices shall be plotted over the period of operation (T) (see Annex B). DIN EN 16058:2012-07 EN 16058:2012 (E) 11 11 Test report The test report shall
15、contain: a) name and address of the test institute; b) name(s), function(s) and signature(s) or equivalent identification of person(s) authorising the test report; c) registration mark or number of the test report; d) name and address of the customer and/or producer of the tested material; e) name a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN160582012INFLUENCEOFMETALLICMATERIALSONWATERINTENDEDFORHUMANCONSUMPTIONDYNAMICRIGTESTFORASSESSMENTOFSURFACECOATINGSWITHNICKELLAYERSLONGTERMTESTPDF

链接地址:http://www.mydoc123.com/p-672625.html