DIN EN 14624-2012 Performance of portable leak detectors and of room monitors for halogenated refrigerants German version EN 14624 2012《移动式检漏器和卤化制冷剂室内监控器的性能》.pdf
《DIN EN 14624-2012 Performance of portable leak detectors and of room monitors for halogenated refrigerants German version EN 14624 2012《移动式检漏器和卤化制冷剂室内监控器的性能》.pdf》由会员分享,可在线阅读,更多相关《DIN EN 14624-2012 Performance of portable leak detectors and of room monitors for halogenated refrigerants German version EN 14624 2012《移动式检漏器和卤化制冷剂室内监控器的性能》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、April 2012 Translation by DIN-Sprachendienst.English price group 12No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS
2、23.040.99; 71.100.45!$?,“1882809www.din.deDDIN EN 14624Performance of portable leak detectors and of room monitors forhalogenated refrigerantsEnglish translation of DIN EN 14624:2012-04Leistung von mobilen Leckdetektoren und Raumberwachungsgerten fr halogenierteKltemittelEnglische bersetzung von DIN
3、 EN 14624:2012-04Performances des dtecteurs de fuite portables et des contrleurs dambiance de fluidesfrigorignes halognsTraduction anglaise de DIN EN 14624:2012-04SupersedesDIN EN 14624:2005-06www.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document compr
4、ises 25 pages03.12 DIN EN 14624:2012-04 2 A comma is used as the decimal marker. National foreword This standard has been prepared by Technical Committee CEN/TC 182 “Refrigerating systems, safety and environmental requirements” (Secretariat: DIN, Germany). The responsible German body involved in its
5、 preparation was the Normenausschuss Kltetechnik (Refrigeration Technology Standards Committee), Working Committee NA 044-00-01 AA Sicherheit und Umweltschutz. Amendments This standard differs from DIN EN 14624:2005-06 as follows: a) Clause 3 “Terms and definitions” has been revised; b) Clause 11 “P
6、erformance tests” has been completely revised; c) an informative Annex B “Correlation between test gas concentration and leakage rate” has been added; d) an informative Annex C “Guidelines for monitoring a machinery room or space for gas leaks” has been added. Previous editions DIN EN 14624: 2005-06
7、 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 14624 January 2012 ICS 23.040.99; 71.100.45 Supersedes EN 14624:2005English Version Performance of portable leak detectors and of room monitors for halogenated refrigerants Performances des dtecteurs de fuite portables et des contrleurs dambiance
8、 de fluides frigorignes halogns Leistung von mobilen Leckdetektoren und Raumberwachungsgerten fr halogenierte Kltemittel This European Standard was approved by CEN on 19 November 2011. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving
9、 this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three offici
10、al versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of A
11、ustria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Ki
12、ngdom. Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14624:2012: EEUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGEN 1462
13、4:2012 (E) 2 Contents Page Foreword 41 Scope 52 Normative references 53 Terms and definitions .54 Symbols and abbreviations 75 Types of portable leak detectors and room monitors 76 General requirements for all portable leak detectors and room monitors 76.1 Gas type 76.2 Capabilities .76.3 Output sig
14、nal 86.4 Response time .86.5 Recovery time (clean up time) 86.6 Repeatability .86.7 Calibration 87 Specific requirements for locating portable leak detectors 87.1 General 87.2 Lowest detectable leakage rate threshold when the leak detector is stationary 97.3 Lowest detectable leakage rate threshold
15、value when the detector probe is moving .97.4 Leak detection in a contaminated environment .98 Specific requirements for room monitors 108.1 General . 108.2 Lowest detectable concentration (lower detection limit) . 108.3 Highest tolerable concentration (upper detection limit) . 108.4 Upper and lower
16、 alarm thresholds 108.5 Response time for alarm trigger . 109 Calibration leaks . 109.1 General . 109.2 Calibration gases 1010 Test apparatus 1110.1 General . 1110.2 Apparatus no. 1: detector probe stationary at the orifice of a calibration leak . 1110.3 Apparatus no. 2: detector probe moved with de
17、fined speed and distance in front of a calibration leak 1110.4 Apparatus no. 3: Chamber with monitored concentration . 1211 Performance tests. 1211.1 Performance test of locating leak detector 1211.1.1 Test no. 1: Static detection 1211.1.2 Test no. 2: dynamic detection limit . 1311.1.3 Test no. 3: d
18、etection limit in contaminated environment . 1311.1.4 Test no. 4: recovery time . 1311.2 Performance tests of room monitor 1311.2.1 General . 1311.2.2 Test a) to determine the upper and lower detection limits . 1311.2.3 Test b) to determine response time 1411.2.4 Test c) to determine recovery time f
19、rom exposure to a large concentration . 1412 Instrument characteristics and reporting of test results 15DIN EN 14624:2012-04 EN 14624:2012 (E) 3 12.1 Characteristics of locating leak detector 1512.2 Characteristics of room monitors 1513 Technical data 1613.1 Locating leak detectors 1613.2 Measuring
20、leak detectors . 1613.3 All portable leak detectors 1613.4 Room monitor 16Annex A (informative) Conversion factors of leakage rate units . 18Annex B (informative) Correlation between test gas concentration and leakage rate 19Annex C (informative) Guidelines for monitoring a machinery room or space f
21、or gas leaks 23DIN EN 14624:2012-04 EN 14624:2012 (E) 4 Foreword This document (EN 14624:2012) has been prepared by Technical Committee CEN/TC “Refrigerating systems, safety and environmental requirements “, the secretariat of which is held by DIN. This European Standard shall be given the status of
22、 a national standard, either by publication of an identical text or by endorsement, at the latest by July 2012, and conflicting national standards shall be withdrawn at the latest by July 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of pat
23、ent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 14624:2005. The following changes have been made during revision: a) Clause 3 “Terms and definitions“ has been revised; b) Clause 11 “Performance tests“ has been co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN146242012PERFORMANCEOFPORTABLELEAKDETECTORSANDOFROOMMONITORSFORHALOGENATEDREFRIGERANTSGERMANVERSIONEN146242012

链接地址:http://www.mydoc123.com/p-667480.html