DIN 8062-2009 Unplasticized polyvinyl chloride (PVC-U) pipes - Dimensions《非增塑聚氯乙烯管(PVC-U) 尺寸》.pdf
《DIN 8062-2009 Unplasticized polyvinyl chloride (PVC-U) pipes - Dimensions《非增塑聚氯乙烯管(PVC-U) 尺寸》.pdf》由会员分享,可在线阅读,更多相关《DIN 8062-2009 Unplasticized polyvinyl chloride (PVC-U) pipes - Dimensions《非增塑聚氯乙烯管(PVC-U) 尺寸》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、October 2009 Translation by DIN-Sprachendienst.English price group 10No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).IC
2、S 23.040.20!$s$“1618001www.din.deDDIN 8062Unplasticized polyvinyl chloride (PVC-U) pipes DimensionsEnglish version of DIN 8062:2009-10Rohre aus weichmacherfreiem Polyvinylchlorid (PVC-U) MaeEnglische bersetzung von DIN 8062:2009-10Tuyaux en chlorure de polyvinyle non plastifi (PVC-U) DimensionsDIN 8
3、062:2009-10SupersedesDIN 8062:1988-11www.beuth.deDocument comprises pagesIn case of doubt, the German-language original shall be considered authoritative.1506.10Traduction anglaise de DIN 8062:2009-10 A comma is used as the decimal marker. Contents Page Foreword3 1 Scope .4 2 Normative references.4
4、3 Terms and definitions 4 4 Material 5 5 Safety factors5 6 Dimensions and designation.5 6.1 General 5 6.2 Outside diameters, wall thicknesses, S/SDR series and masses .6 6.3 Tolerances on mean outside diameter and out-of-roundness 8 6.4 Tolerances on wall thickness9 7 Allowable working pressures10 7
5、.1 Allowable working pressures for pipes conveying water10 7.2 Allowable working pressures for pipes conveying other liquids10 8 Form supplied.13 9 Marking13 Annex A (informative) Explanatory notes.14 Bibliography 15 Figures Figure 1 Outside diameter and wall thickness5 Tables Table 1 Outside diamet
6、ers, wall thicknesses, S/SDR series and masses .6 Table 2 Tolerances on mean outside diameter and out-of roundness.8 Table 3 Tolerances on wall thickness9 Table 4 Allowable working pressure for PVC-U pipes with a safety factor (SF) = 2,5 11 Table 5 Allowable working pressures for PVC-U pipes with a
7、safety factor (SF) = 2,0 12 Table 6 Tolerances for pipe lengths.13 2 DIN 8062:2009-10 Foreword This document has been prepared by Working Committee NA 054-05-01 AA Auendurchmesser und Betriebsdrcke of the Normenausschuss Kunststoffe (FNK) (Plastics Standards Committee). See Annex A for the relations
8、hip to International Standard ISO 161-1 published by the International Organization for Standardization. Attention is drawn to the possibility that some elements of this document may be the subject of patent rights. DIN shall not be held responsible for identifying any or all such patent rights. Ame
9、ndments This standard differs from DIN 8062:1988-11 as follows: a) The title has been changed. b) The content has been editorially revised. c) Materials PVC-U-K and PVC-HI have been deleted. d) Information regarding pipe series and pressure ratings have been deleted from the tables giving dimensions
10、. e) Information on pipe series S = 5 has been added. f) A table giving allowable working pressures for a safety factor SF = 2 is now included. g) The table giving tolerances on mean outside diameters has been expanded to include tolerances on out-of-roundness. h) Values in the table giving dimensio
11、ns have been harmonized with ISO 4065. i) The table giving allowable working pressures for pipes conveying fluids to which PVC-U is resistant has been deleted. j) The average density of pipes has been increased to 1,42 g/cm3. k) In the table giving outside diameters, wall thicknesses and masses, the
12、 masses have been calculated for an average density of 1,42 g/cm3. Previous editions DIN 8062: 1941x-07, 1959-03, 1960x-07, 1966-09, 1971-04, 1974-02, 1988-11 3 DIN 8062:2009-10 1 Scope This standards applies to unplasticized polyvinyl chloride (PVC-U) pipes that meet the requirements of DIN 8061. A
13、ttention is brought to the fact that there are European product standards which apply to specific applications; these are to be complied with where relevant. Some of these product standards are listed in the bibliography for the information of users of this standard. Please note that because Europea
14、n Standards are continually being developed, this list is not exhaustive. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenc
15、ed document (including any amendments) applies. DIN 8061, Unplasticized polyvinyl chloride (PVC-U) pipes General quality requirements and testing DIN EN ISO 12162, Thermoplastics materials for pipes and fittings for pressure applications Classification, designation, and design coefficient ISO 4065,
16、Thermoplastic pipes Universal wall thickness table ISO 11922-1, Thermoplastics pipes for the conveyance of fluids Dimensions and tolerances Part 1: Metric series 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 pipe series number S nominal pip
17、e series number taken from ISO 4065 NOTE To calculate wall thickness e using equation (1), the “calculated values” for S specified in ISO 4065 are to be used. 1S2 +=de (1) 3.2 standard dimension ratio SDR ratio of the nominal outside diameter of a pipe to its nominal wall thickness NOTE Calculated u
18、sing equation (2). ed+1S2 = SDR (2) where S is the nominal pipe series number. 4 DIN 8062:2009-10 5 3.3 out-of-roundness ovality difference between the measured maximum outside diameter and the measured minimum outside diameter in the same cross-section of the pipe 4 Material The MRS classification
19、of PVC-U material for pipes is based on its long-term hydrostatic strength at 20 C over 50 years with water as the exposure medium and at a suitable pressure, and is specified in DIN EN ISO 12162. The minimum long-term hydrostatic strength (MRS) is 25 MPa. 5 Safety factors Safety factors are specifi
20、ed in product standards. 6 Dimensions and designation 6.1 General The principle dimensions for designating pipes are shown in Figure 1. Figure 1 Outside diameter and wall thickness Designation of a pipe with an outside diameter d = 32 mm and a wall thickness e = 1,8 mm made from PVC-U: Pipe DIN 8062
21、 32 1,8 PVC-U DIN 8062:2009-10 6 6.2Outside diameters,wallthicknesses,S/SDR series andmasses Table 1 Outside diameters, wall thicknesses,S/SDR seriesandmassesDimensionsin millimetresPipe series S 63 25 20 16,7 12,5 10 8 6,3 5 4 Standard dimension ratio SDR 127a51 41 34,4 26 21 17 13,6 11c9cd mm e mm
22、 Massbkg/m e mmMassbkg/m e mmMassbkg/m e mmMassbkg/m e mmMassbkg/m e mmMassbkg/m e mmMassbkg/m e mmMassbkg/m e mmMassbkg/m e mmMassbkg/m 5 1,0 0,020 6 1,0 0,025 8 1,0 0,035 10 1,00,045 1,2 0,054 12 1,10,062 1,4 0,074 16 1,20,091 1,50,108 1,8 0,125 20 1,50,139 1,90,168 2,3 0,199 25 1,50,177 1,90,215
23、2,30,255 2,8 0,299 32 1,60,243 1,90,280 2,40,347 2,90,405 3,6 0,489 40 1,6 0,307 1,90,355 2,40,442 3,00,533 3,70,642 4,5 0,761 50 1,5 0,366 2,0 0,469 2,40,560 3,00,678 3,70,821 4,60,995 5,6 1,18 63 1,6 0,491 1,9 0,571 2,5 0,739 3,00,866 3,81,08 4,71,31 5,81,571 7,0 1,85 75 1,5 0,556 1,9 0,683 2,2 0,
24、793 2,9 1,01 3,61,24 4,51,52 5,61,85 6,82,191 8,4 2,64 90 1,8 0,785 2,2 0,957 2,7 1,15 3,5 1,46 4,31,77 5,42,18 6,72,64 8,23,172 10,1 3,80 110 1,8 0,964 2,2 1,18 2,7 1,41 3,2 1,66 4,2 2,14 5,32,65 6,63,24 8,13,91 10,04,700 12,3 5,64 125 1,8 1,10 2,5 1,50 3,1 1,84 3,7 2,16 4,8 2,75 6,03,39 7,44,13 9,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN80622009UNPLASTICIZEDPOLYVINYLCHLORIDEPVCUPIPESDIMENSIONS 非增塑 聚氯乙烯 PVCU 尺寸 PDF

链接地址:http://www.mydoc123.com/p-661726.html