DIN 743-4-2012 Calculation of load capacity of shafts and axles - Part 4 Fatigue limit endurance limit - Equivalently damaging continuous stress《轴和柄负载能力的计算 第4部分 疲劳极限、持久极限 等效破坏连续应力》.pdf
《DIN 743-4-2012 Calculation of load capacity of shafts and axles - Part 4 Fatigue limit endurance limit - Equivalently damaging continuous stress《轴和柄负载能力的计算 第4部分 疲劳极限、持久极限 等效破坏连续应力》.pdf》由会员分享,可在线阅读,更多相关《DIN 743-4-2012 Calculation of load capacity of shafts and axles - Part 4 Fatigue limit endurance limit - Equivalently damaging continuous stress《轴和柄负载能力的计算 第4部分 疲劳极限、持久极限 等效破坏连续应力》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、December 2012 Translation by DIN-Sprachendienst.English price group 8No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).IC
2、S 21.120.10!%,d.“2096511www.din.deDDIN 743-4Calculation of load capacity of shafts and axles Part 4: Fatigue limit, endurance limit Equivalently damaging continuous stress,English translation of DIN 743-4:2012-12Tragfhigkeitsberechnung von Wellen und Achsen Teil 4: Zeitfestigkeit, Dauerfestigkeit Sc
3、hdigungsquivalente Spannungsamplitude,Englische bersetzung von DIN 743-4:2012-12Calcul de la capacit des arbres et axes Partie 4: Rsistance la fatigue pour une dure de vie limite, rsistance la fatigue pourunedure de vie illimite Amplitude de contrainte pour endommagement quivalent,Traduction anglais
4、e de DIN 743-4:2012-12www.beuth.deDocument comprises 11 pagesIn case of doubt, the German-language original shall be considered authoritative.08.15 DIN 743-4:2012-10 2 A comma is used as the decimal marker. Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Symbols, designations and units
5、 .4 4 Calculation 5 4.1 General 5 4.2 Single direction of loading 5 4.2.1 Calculation of safety factor for time-constant amplitude in the limited life strength domain 5 4.2.2 Calculation of safety factor for load spectra in the limited life strength and fatigue strength domains .7 4.3 Combined loads
6、 10 Bibliography . 11 Figures Figure 1 Limited life strength value ANK6 Figure 2 Method according to Miner extended . 8 DIN 743-4:2012-10 3 Foreword This standard has been prepared by Working Committee NA 060-34-32 AA Wellen- und Welle-Nabe-Verbindungen of Section Antriebstechnik of the Normenaussch
7、uss Maschinenbau (Mechanical Engineering Standards Committee) in DIN. DIN 743, Calculation of load capacity of shafts and axles comprises: Part 1: General Part 2: Theoretical stress concentration factors and fatigue notch factors Part 3: Strength of materials Part 4: Fatigue limit, endurance limit -
8、 Equivalently damaging continuous stress Supplement 1: Examples to part 1 to 3 Supplement 2: Examples to part 4 DIN 743-4:2012-10 4 1 Scope This standard applies to the calculation and verification of the safety of shafts and axles, in accordance with DIN 743-1, in the limited life strength domain (
9、fatigue failure) as well as in the limited life strength and fatigue strength domains for load spectrum loading. Users can make use of their own verified experience or results. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated
10、 references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. DIN 743-1, Calculation of load capacity of shafts and axles Part 1: General 3 Symbols, designations and units Symbol Designation Unit DMMiner sum _ i
11、 Load bin of the load spectrum _ j Number of load spectrum bins _ KKLoad spectrum factor _ K Corrected number of load spectrum bins _ neCorrected number of load cycles in bin k _ ni Number of load cycles in bin i _ NDSalient point of the Whler curve between the limited life strength and fatigue stre
12、ngth domains _ NL Required number of load cycles _ N* Reference number of load cycles _ NSSalient point of the Whler curve between the quasi-static strength and the limited life strength domain _ q Exponent of the Whler curve _ S Safety of the component _ SminRequired minimum safety of the component
13、 _ n Shape of the load spectrum _ zd,bADK,ttADKFatigue strength value N/mm2zd,bANK,ttANKLimited life strength value N/mm2DIN 743-4:2012-10 5 zd,ba,ttaEquivalent damaging stress amplitude N/mm2zd,bai,ttaiStress amplitude of load bin i N/mm2zd,ba1,tta1 Maximum stress amplitude of the given load spectr
14、um N/mm2S,StSingle safety _ Subscripts b Bending t, Torsion zd Tension/compression Tension/compression, bending 4 Calculation 4.1 General The method described in this standard takes into account the complete load spectrum covering the number of load cycles before the salient point NDof the Whler cur
15、ve. The decrease in fatigue strength caused by higher effective loads has been considered by approximation. The influence of order is not taken into account. The assumptions on which the Whler curve is based apply for notched round bars. ADKshall be calculated in accordance with DIN 743-1. For cases
16、 where m= constant and/or tm= constant it shall be assumed that mand ttmhave a constant value in all bins of the load spectrum and in the case of load increases remain constant in all bins of the load spectrum; this condition accordingly applies to zd,ba/m= constant and/or a/m= constant, i.e. the re
17、lation of the stress amplitude to the mean stress is constant in all bins of the load spectrum. 4.2 Single direction of loading 4.2.1 Calculation of safety factor for time-constant amplitude in the limited life strength domain 4.2.1.1 Basic equations The safety values shall be calculated on the basi
18、s of the maximum endurable stress (strength) and the stress existing in the case of application. The calculated safety factor S shall be equal to or greater than the minimum safety factor Smin: Smin 1,2 (1) The principles of the calculation method itself require a minimum safety factor Smin= 1,2. Un
19、certainties in the assumed load, possible consequential damage, etc. require higher safety factors. They shall be agreed upon or determined by the designer, depending on the case of application. DIN 743-4:2012-10 6 4.2.1.2 Working stresses If a calculation is to be made in the limited life strength
20、domain without taking into consideration load spectra, the working stresses shall be determined according to DIN 743-1. If load spectra are to be taken into consideration, proceed as described in subclause 4.2.2 of this standard. 4.2.1.3 Limited life strength value Regarding the limited life strengt
21、h domain the Whler curve equation, which is used to convert fatigue strength to limited life strength, generally applies: ,Dqzd bANK zd bADKLNN= (2) where q is the exponent of the Whler curve for bending DqtANK tADKLNNttt= (3) where qtis the exponent of the Whler curve for torsion. Unless otherwise
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便