DIN 53177-2002 Binders for paints and varnishes - Measurement of the dynamic viscosity of liquid resins Resin solutions and oils by the capillary viscosimeter of isocelses type acc.pdf
《DIN 53177-2002 Binders for paints and varnishes - Measurement of the dynamic viscosity of liquid resins Resin solutions and oils by the capillary viscosimeter of isocelses type acc.pdf》由会员分享,可在线阅读,更多相关《DIN 53177-2002 Binders for paints and varnishes - Measurement of the dynamic viscosity of liquid resins Resin solutions and oils by the capillary viscosimeter of isocelses type acc.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、ICS 87.060.20Bindemittel fr Beschichtungsstoffe Messung der dynamischenViskositt von flssigen Harzen, Harzlsungen und len mit demKapillarviskosimeter gleichschenkliger Bauart nach UbbelohdeIn keeping with current practice in standards published by the International Organization for Standardization(I
2、SO), a comma has been used throughout as the decimal marker.Ref. No. DIN 53177 : 2002-11English price group 06 Sales No. 010612.03DEUTSCHE NORM November 200253177Continued on pages 2 to 6. No part of this translation may be reproduced without the prior permission ofDIN Deutsches Institut fr Normung
3、e.V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).Determination of dynamic viscosity of liquidresins, resin solutions and oils using theUbbelohde capillary viscometerTranslation by DIN-Sprachendienst.In case of doubt, the German-
4、language original should be consulted as the authoritative text.ForewordThis standard has been prepared by Technical Committee Lackrohstoffe of the NormenausschussBeschichtungsstoffe und Beschichtungen (Paints and Varnishes Standards Committee).The capillary viscometers specified in DIN 51562-1 to D
5、IN 51562-3 for measuring kinematic viscosity haveproved satisfactory in practice, with a repeatability limit of 0,2 % if the Hagenbach correction is taken intoaccount. The measurement conditions specified in those standards have been included in this standard sothat viscometers having the same visco
6、meter constants are designated in the same way in both standards.The requirement for a somewhat more rugged viscometer for measuring the dynamic viscosity directlywithout determining the density is fulfilled by a viscometer having equal limbs, which was also developedby Ubbelohde. With a repeatabili
7、ty limit of 1 % (absolute), better information can be obtained with flow timesof around 100 s than with flow times using the ISO cup (cf. DIN EN ISO 2431), despite the omission of theHagenbach correction, which is below 5 % even with viscometer of size no. 1c.AmendmentsThis standard differs from the
8、 November 1990 edition in that it has been editorially revised and the normativereferences have been updated.Previous editionsDIN 53177: 1974-07, 1990-11.All dimensions are in millimetres.1 ScopeThe method described in this standard serves to determine the dynamic viscosity of liquid resins, resinso
9、lutions, oils and other liquids having Newtonian flow and used to produce paints and varnishes, impreg-nating resins, etc. The viscometers specified in this standard are intended for use for flow times of at least50 s and at temperatures ranging from 10 C to about 90 C, and are operated at measuring
10、 ranges extend-ing from 1,5 mPa. s to over 5 000 mPa. s, the upper limit being set by the onset of non-Newtonian flow,where viscosities of over 12 000 mPa. s are frequently encountered. In this context, reference is made toDIN 53012.SupersedesNovember 1990 edition.Page 2DIN 53177 : 2002-112 Normativ
11、e referencesThis standard incorporates, by dated or undated reference, provisions from other publications. These norma-tive references are cited at the appropriate places in the text, and the titles of the publications are listed below.For dated references, subsequent amendments to or revisions of a
12、ny of these publications apply to thisstandard only when incorporated in it by amendment or revision. For undated references, the latest edition ofthe publication referred to applies.DIN 1342-1 Viscosity Rheological conceptsDIN 51562-1 Determination of kinematic viscosity using the Ubbelohde viscome
13、ter Apparatus andmeasurement procedureDIN 51562-2 Determination of kinematic viscosity using the Ubbelohde microviscometerDIN 51562-3 Determination of kinematic viscosity using the Ubbelohde viscometer Relative incre-ment at short flow timesDIN 53012 Capillary viscometry of Newtonian liquids Sources
14、 of error and correctionsDIN EN ISO 2431 Determination of flow time of paints and varnishes by use of flow cups (ISO 2431 : 1993+ Corr 1 : 1994)DIN EN ISO 15528 Paints, varnishes and raw materials for paints and varnishes Sampling (ISO 15528 : 2000)ISO 719 : 1985 Glass Hydrolytic resistance of glass
15、 grains at 98 C Method of test and classificationDIN ISO 3310-1 Test sieves Technical requirements and testing Part 1: Test sieves of metal wire cloth(ISO 3310-1 : 2000)3 ConceptsSee DIN 1342-1.4 PrincipleThe method is based on laminar flow of the test liquid through a capillary. Since the hydrostat
16、ic internal pressureis negligible during the measurement, the density of the test liquid is not involved and surface tension hasvirtually no effect, the method permits direct measurement of dynamic viscosity and requires the applicationof external pressure.5 Sampling and sample preparationA represen
17、tative sample of the test liquid sufficient for at least two measurements (about 20 ml for each test)shall be collected as described in DIN EN ISO 15528, removing suspended particles before measurement byfiltration or by sieving through an analytical sieve of aperture size 0,2 mm (as in DIN ISO 3310
18、-1).6 Number of measurementsViscosity shall be measured twice using a fresh sample each time.7 ApparatusThe following equipment shall be used.7.1 Ubbelohde capillary viscometer having two equal limbsThe viscometer (see figure 1) shall be made of glass and have a hydrolytic resistance corresponding t
19、o classHBG 1 as in ISO 719. Each limb shall have a bulb of equal volume at the same height1), one limb containing ameasuring capillary (sealed-in) with the viscometer constant permanently marked on it (the constant can alsobe determined in-house as described in subclause 8.3), the other limb having
20、permanent measuring marks (M1and M2).Since the diameter of the capillaries depends on the viscosity range required, several viscometers havingcapillaries of the same length (100 mm), but different internal capillary diameters, are used (see table 1 andfigure 1 for other dimensions).Calibrated precis
21、ion glass tubes shall be used for the capillaries. The volume of each of the two bulbs measuredbetween the marks shall be (7 t 0,5) ml. The limb above M2 may either be bent over about 50 mm below theend of the other limb, as shown in figure 1, or be straight and of the same length as the latter.1) T
22、he accuracy of the measurements is unaffected by whether the bulbs are spherical or somewhat elongatedat the tube attachment point, but it is important that their volumes are as equal as possible.Page 3DIN 53177 : 2002-11NOTE: The holder shown in figure 2 is suitable for suspending viscometers with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN531772002BINDERSFORPAINTSANDVARNISHESMEASUREMENTOFTHEDYNAMICVISCOSITYOFLIQUIDRESINSRESINSOLUTIONSANDOILSBYTHECAPILLARYVISCOSIMETEROFISOCELSESTYPEACCPDF

链接地址:http://www.mydoc123.com/p-658980.html