DIN 18008-2-2010 Glass in Building - Design and construction rules - Part 2 Linearly supported glazings《建筑玻璃 设计和建造规则 第2部分 直线支撑玻璃窗》.pdf
《DIN 18008-2-2010 Glass in Building - Design and construction rules - Part 2 Linearly supported glazings《建筑玻璃 设计和建造规则 第2部分 直线支撑玻璃窗》.pdf》由会员分享,可在线阅读,更多相关《DIN 18008-2-2010 Glass in Building - Design and construction rules - Part 2 Linearly supported glazings《建筑玻璃 设计和建造规则 第2部分 直线支撑玻璃窗》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、December 2010DEUTSCHE NORM Normenausschuss Bauwesen (NABau) im DINDIN-SprachendienstEnglish price group 9No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale
2、for German Standards (DIN-Normen).ICS 81.040.20!$zN“1888743www.din.deDDIN 18008-2Glass in building Design and construction rules Part 2: Linearly supported glazingsEnglish translation of DIN 18008-2:2010-12Glas im Bauwesen Bemessungs- und Konstruktionsregeln Teil 2: Linienfrmig gelagerte Verglasunge
3、nEnglische bersetzung von DIN 18008-2:2010-12Verre dans la construction Rgles de calcul et de la construction Partie 2: Vitrages fixation linareTraduction anglaise de DIN 18008-2:2010-12www.beuth.deDocument comprises 13 pages09.12 DIN 18008-2:2010-12 2 A comma is used as the decimal marker. Contents
4、 Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions . 4 4 Conditions for use . 4 5 Additional provisions for horizontal glazing 5 6 Additional provisions for vertical glazing . 5 7 Actions and verifications 6 Annex A (informative) Approximate method for the determination of c
5、limate loads and for the distribution of actions . 7 A.1 Calculation of the individual panes proportions aand iin the total bending stiffness . 7 A.2 Calculation of the characteristic edge length a* 8 A.3 Calculation of factor . 8 A.4 Determination of the isochoric pressure p09 A.5 Distribution of a
6、ctions . 9 Bibliography 13 Tables Table A.1 Factor BV8 Table A.2 Distribution of the actions 9 Table A.3 Proportion of the stiffness of individual panes in the total stiffness, and characteristic edge length 11 DIN 18008-2:2010-12 3 Foreword This standard has been prepared by Working Committee NA 00
7、5-09-25 AA Bemessungs- und Konstruktions-regeln fr Bauprodukte aus Glas of the Normenausschuss Bauwesen (NABau) (Building and Civil Engineering Standards Committee).*)DIN 18008, Glass in building Design and construction rules consists of the following parts: Part 1: Terms and general basics Part 2:
8、Linearly supported glazing Part 3: Point-fixed glazing1) Part 4: Additional requirements for barrier glazing1) Part 5: Additional requirements for glazing accessible for public1) Part 6: Additional requirements for glazing accessible for maintenance1) Part 7: Special structures1)*)Translators note.
9、This translation takes into account Corrigendum 1, issued in April 2011, which corrected Subclause 7.2. 1) in preparation DIN 18008-2:2010-12 4 1 Scope This part of DIN 18008, in combination with DIN 18008-1, applies to flat infill glazing supported on at least two opposite sides using mechanical fa
10、steners (e.g. clamping strips with screw connections), with the support being plane and continuously linear. Glazing which is also provided with point fixings (e.g. edge clamps and/or bolted connections through glass holes) is dealt with in DIN 18008-31). For glazing which can be walked on or driven
11、 on, which serves as balustrade or barriers or which is intended to be subject to hydrostatic loads (e.g. aquarium glazing), further requirements shall be taken into consideration. Depending on its vertical inclination, linearly supported glazing in the context of this standard is divided into horiz
12、ontal glazing: inclination 10 and vertical glazing: inclination 10. The provisions for horizontal glazing are also applicable to vertical glazing, provided this e.g. shed roofs with a potential for lateral snow loads is not only subject to short-term variable actions. 2 Normative references The foll
13、owing referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. DIN 1055-100:2001-03, Actions on structures Part 100: Bas
14、es of structural design Safety concept and design rules DIN 1259-1, Glass Terminology for glass types and groups DIN 1259-2, Glass Terminology of glass products DIN 18008-1:2010-12, Glass in building Design and construction rules Part 1: Terms and general bases DIN ISO 8930, General principles on re
15、liability for structures List of equivalent terms ISO 6707-1, Building and civil engineering Vocabulary Part 1: General terms 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 6707-1, DIN ISO 8930, DIN 1259-1, DIN 1259-2, DIN 1055-100 and DIN 18008-1 a
16、pply. 4 Conditions for use 4.1 The glass bite shall be chosen such that long-term structural stability of the glazing is ensured. Unless specified otherwise in the following, a minimum edge cover of 10 mm is required. 4.2 The linear support shall be bilaterally effective (for pressure and suction) o
17、n at least two opposite sides, normal to the plane of the pane. In the case of multiple layers, the linear support shall be effective for all panes. 1) in preparation DIN 18008-2:2010-12 5 4.3 An edge can be regarded as being supported in a plane and linear way if, relative to the supported length o
18、f the pane, the design value of the deflection of the substructure does not exceed 1/200. By way of simplification, the design value of the stress may be determined in accordance with DIN 1055-100:2001-03, Equation (22). 4.4 The glazing shall be professionally installed with setting blocks. 5 Additi
19、onal provisions for horizontal glazing 5.1 In the case of single glazing or the lower pane of insulating glazing, respectively, only laminated safety glass (LSG) made of float glass or of heat-strengthened glass (HSG) or wired glass may be used in order to protect public areas. 5.2 Drill holes and r
20、ecesses shall not result in a reduced residual load-bearing capacity. 5.3 LSG panes made of HSG may have drill holes for fixing clamping strips. 5.4 LSG panes with an effective span exceeding 1,2 m shall be supported on all sides. 5.5 The nominal thickness of the interlayer of LSG shall be 0,76 mm m
21、in. In cases of all-sided support of panes with an effective span of 0,8 m max. in the main supporting direction, an interlayer of nominal thickness 0,38 mm may also be used. 5.6 Using wired glass is only permissible up to an effective span of 0,7 m max. in the main supporting direction. In these ca
22、ses, the glass bite shall be 15 mm min. The edges of wired glass shall not be subject to persistent humidity. Free edges may be exposed to weathering, provided their drying is not inhibited. 5.7 The projection parallel and perpendicular to the support of the free edge of LSG beyond the area formed b
23、y the linear supports shall be 30 % max. of the supporting length but not more than 300 mm. A LSG pane shall not project beyond the laminate area (e.g. drip edges of overhead glazings) by more than 30 mm. 5.8 The performance of the lower pane of horizontal glazing made of insulating glass shall alwa
24、ys be verified with the load acting on the upper panes, including in the case of the upper panes failing. Failure of the upper panes is an “accidental” design situation. Here, DIN 1055-100:2001-03, 9.4 (Equation (15), applies. 5.9 Deviations from the additional provisions for horizontal glazing give
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN1800822010GLASSINBUILDINGDESIGNANDCONSTRUCTIONRULESPART2LINEARLYSUPPORTEDGLAZINGS 建筑 玻璃 设计 建造 规则 部分

链接地址:http://www.mydoc123.com/p-653827.html