CSA T568 2-4-2005 Commercial building telecommunications cabling standard Part 2 Balanced twisted pair cabling components Addendum 4 Solderless connection reliability requiremen.pdf
《CSA T568 2-4-2005 Commercial building telecommunications cabling standard Part 2 Balanced twisted pair cabling components Addendum 4 Solderless connection reliability requiremen.pdf》由会员分享,可在线阅读,更多相关《CSA T568 2-4-2005 Commercial building telecommunications cabling standard Part 2 Balanced twisted pair cabling components Addendum 4 Solderless connection reliability requiremen.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 T568.2-4-05(ANSI/TIA/EIA-568-B.2-4-2002)Commercial building telecommunications cabling standard Part 2: Balanced twisted pair cabling components Addendum 4 Solderless connection reliability requirements for copper connecting hardware CSA StandardT568.2-4-05 (ANSI/TIA/EIA-568-B.2-4-2002) Commercial
2、building telecommunications cabling standard Part 2: Balanced twisted pair cabling components Addendum 4 Solderless connection reliability requirements for copper connecting hardware Published in May 2005 by Canadian Standards Association A not-for-profit private sector organization 5060 Spectrum Wa
3、y, Suite 100, Mississauga, Ontario, Canada L4W 5N61-800-463-6727 416-747-4044 Visit our Online Store at www.ShopCSA.ca Commercial building telecommunications cabling standard Part 2: Balanced twisted pair cabling components Addendum 4 Solderless T568.2-4-05 connection reliability requirements for co
4、pper connecting hardware CSA/2 Canadian Standards Association May 2005 T568.2-4-05 Commercial building telecommunications cabling standard Part 2: Balanced twisted pair cabling components Addendum 4 Solderless connection reliability requirements for copper connecting hardware CSA Preface This is the
5、 first edition of CSA T568.2-4, Commercial building telecommunications cabling standard Part 2: Balanced twisted pair cabling components Addendum 4 Solderless connection reliability requirements for copper connecting hardware. This Standard is an adoption of the identically titled ANSI/TIA/EIA (Amer
6、ican National Standards Institute/Telecommunications Industry Association/Electronic Industries Alliance) Standard 568-B.2-4-2002 and is the product of the Telecommunications Industry Association TR-42 Technical Committee, which included a number of Canadian members in order to ensure that Canadian
7、perspectives and requirements were addressed. It is written in SI (metric) units with yard/pound (imperial) units in parentheses. This Standard has been adopted with no technical deviations. Where code requirements or regulations necessitate changes from US to Canadian references, they should be mad
8、e by the user, as follows: (a) Throughout this Standard, replace the term “American” with “Canadian”, as applicable. (b) Throughout this Standard, replace the term “state” with “provincial or territorial”, as applicable. (c) Throughout this Standard, replace “NEC” with “CE Code, Part I” (Canadian El
9、ectrical Code), as applicable. In addition, (i) where reference is made to “conduit”, replace it with “conduit/EMT” (electrical metallic tubing) because, in accordance with the Canadian Electrical Code, Part I, EMT is not considered a type of conduit; and (ii) the definitions of the following terms
10、are to be taken from the Canadian Electrical Code, Part I: “Bonding”, “Ground”, and “Raceway”. (d) Throughout this Standard, where reference is made to “FCC”, replace it with “CRTC” (Canadian Radio-television and Telecommunications Commission), or “Industry Canada”, as applicable. (e) The following
11、Standard, published by the Canadian Standards Association, is an adoption of a TIA/EIA Standard. The requirements of this CSA Standard take precedence over the TIA/EIA Standard on which it is based; any reference in CSA T568.2-4 to the TIA/EIA Standard is to be replaced by a reference to the equival
12、ent Canadian Standard: T568.2-05, Commercial building telecommunications cabling standard Part 2: Balanced twisted-pair cabling components. Commercial building telecommunications cabling standard Part 2: Balanced twisted pair cabling components Addendum 4 Solderless T568.2-4-05 connection reliabilit
13、y requirements for copper connecting hardware May 2005 Canadian Standards Association CSA/3 (f) Throughout this Standard, replace the term “Listed” with “Approved as applied to electrical equipment”. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Telecommunication
14、s Wiring Systems, under the jurisdiction of the Strategic Steering Committee on Information and Communications Technology, and has been formally approved by the Technical Committee. A list of the members of the Technical Committee is available upon request. May 2005 Canadian Standards Association 20
15、05 All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. TIA/EIA material is reprinted with permission. Inquiries regarding this CSA Standard should be addressed to Canadian Standards Association 5060 Spectrum Way, Su
16、ite 100, Mississauga, Ontario, Canada L4W 5N6 1-800-463-6727 416-747-4044 www.csa.ca ANSI/TIA/EIA-568-B.2-4-2002 Approved: June 13, 2002 TIA/EIA STANDARD Cm TIA/EIA-568-B.2-4 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted Pair Cabling Components Addendum 4 Solderles
17、s Connection Reliability Requirements for Copper Connecting Hardware TIA/EIA-568-B.2-4 (Addendum No. 4 to TIA/EIA-568-B.2) JUNE 2002 TELECOMMUNICATIONS INDUSTRY ASSOCIATION The Telecommunications Industry Association represents the communications sector of NOTICE TIA/EIA Engineering Standards and Pu
18、blications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particula
19、r need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of TIA/EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use
20、by those other than TIA/EIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by TIA/EIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA/EIA does not assume any liability t
21、o any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to es
22、tablish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 3-4426-AD4, formulated under the cognizance of the TIA TR-42.7 Subcommittee on Telecommunications Copper Cabling Systems.) Published by g211TELECO
23、MMUNICATIONS INDUSTRY ASSOCIATION 2002 Standards and Technology Department 2500 Wilson Boulevard Arlington, VA 22201 All rights reserved PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the TIA and may not be reproduced without permission. Organizations may obtain permission to reproduc
24、e a limited number of copies through entering into a license agreement. For information, contact: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 or call U.S.A. and Canada 1-800-854-7179, International (303) 397-7956 NOTICE OF DISCLAIMER AND LIMITATION OF LIABILITY The do
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAT568242005COMMERCIALBUILDINGTELECOMMUNICATIONSCABLINGSTANDARDPART2BALANCEDTWISTEDPAIRCABLINGCOMPONENTSADDENDUM4SOLDERLESSCONNECTIONRELIABILITYREQUIREMENPDF

链接地址:http://www.mydoc123.com/p-621641.html