CSA AM CSA ANSI Z21 47A-2007 Gas-Fired Central Furnaces Addenda to the Fifth Edition [Superseded CSA AM Z21 64A CSA AM Z21 64 CSA AM Z21 64 CSA AM Z21 64]《燃气中央熔炉 第5版补遗[代替 CSA AM Z2.pdf
《CSA AM CSA ANSI Z21 47A-2007 Gas-Fired Central Furnaces Addenda to the Fifth Edition [Superseded CSA AM Z21 64A CSA AM Z21 64 CSA AM Z21 64 CSA AM Z21 64]《燃气中央熔炉 第5版补遗[代替 CSA AM Z2.pdf》由会员分享,可在线阅读,更多相关《CSA AM CSA ANSI Z21 47A-2007 Gas-Fired Central Furnaces Addenda to the Fifth Edition [Superseded CSA AM Z21 64A CSA AM Z21 64 CSA AM Z21 64 CSA AM Z21 64]《燃气中央熔炉 第5版补遗[代替 CSA AM Z2.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI Z21.47a-2007CSA 2.3a-2007Addenda to the Fifth Edition of Z21.47-2006 CSA 2.3-2006American National Standard/ CSA Standard forGas-Fired Central FurnacesCopyright CSA America, Inc. Provided by IHS under license with CSA/AM Not for ResaleNo reproduction or networking permitted without license from
2、 IHS-,-,-Standard DeveloperAPPROVEDCSA AMERICA INC. 8501 East Pleasant Valley RoadCleveland, Ohio 44131CANADIAN STANDARDS ASSOCIATION5060 Spectrum Way, Suite 100Mississauga, Ontario, Canada L4W 5N6Published - October 2007Copyright 2007Canadian Standards AssociationPermission is granted to republish
3、material herein in laws or ordinances, and in regulations, administrative orders, or similar documents issued by public authorities. Those desiring permission for other republication should consult Canadian Standards Association, 5060 Specrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.Copy
4、right 2007CSA America, Inc.Permission is granted to republish material herein in laws or ordinances, and in regulations, administrative orders, or similar documents issued by public authorities. Those desiring permission for other republication should consult CSA America, Inc., 8501 East Pleasant Va
5、lley Road, Cleveland, Ohio 44131.PrefaceThe standards set forth herein apply to the fifth edition of the Standard for Gas-Fired Central Furnaces, Z21.47-2006 CSA 2.3-2006 and supersede corresponding standards therein. Following their preparation by the supervising Technical Advisory Group, they were
6、 accepted by the American National Standards Institute (ANSI) and the Interprovincial Gas Advisory Council (IGAC), and subsequently approved.NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.July 19, 2007American National Standards Institute, Inc.September 14, 2007Int
7、erprovincial Advisory Council Effective in Canada May 1, 2009IGACCopyright CSA America, Inc. Provided by IHS under license with CSA/AM Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-1Addenda to American National Standard/ CSA Standard for Gas-Fired Central Furnace
8、s Part I: Construction1.24 Installation Manuals1.24.6Installation manuals for installing vents, venting systems and provisions for adequate combustion and ventilation air shall include the following instructions:a. A furnace shall not be connected to a chimney flue serving a separate appliance desig
9、ned to burn solid fuel. (See Exhibit K, Items Unique to One Country).b. Provisions for adequate combustion and ventilation air in accordance with one of the following:1. Section 5.3, Air for Combustion and Ventilation, of the National Fuel Gas Code, ANSI Z223.1/NFPA 54,2. Sections 7.2, 7.3 or 7.4 of
10、 Natural Gas and Propane Installation Code, CSA B149.1, or3. Applicable provisions of the local building code.c. If the furnace is intended for use with a listed Type B vent or vent connector, the specified type of Type B vent or vent connector to be used with the listed clearances from combustible
11、construction. (Also see 1.27.9-e).d. For Category II, III or IV furnaces:The manufacturers instructions shall specify the type of venting material to be used, vent size, and the minimum and maximum vent lengths.1. When the manufacturer supplies the venting system, the instructions shall include a pa
12、rts list andinstructions covering the installation of properly identified parts to provide for the venting of the vent gases to the outdoors (see 1.2.25).2. When the parts for venting the vent gases are not provided by the furnace manufacturer and they are specific types listed by a nationally recog
13、nized testing agency, these instructions shall clearly identify and specify the use of the specific parts, and the standard under which the vent system components are listed. The instructions shall indicate that only pipe listed under the specific standard shall be used to vent the furnace. (See 1.2
14、7.6-f and -g.)e. For Category II, III and IV furnaces, the venting system shall be installed in accordance with the furnace manufacturers instructions.Copyright CSA America, Inc. Provided by IHS under license with CSA/AM Not for ResaleNo reproduction or networking permitted without license from IHS-
15、,-,-2f. When an existing Category I furnace is removed or replaced, the original venting system may no longer be sized to properly vent the attached appliances. Instructions shall also indicate effects of an improperly sized venting system (formation of condensate, leakage, spillage, etc.) and shall
16、 specify the following test procedure.g. If a furnace is marked, “Category I or Category III” per 1.27.3-b4, the installation manuals shall specify the venting system to be used for both categories.h. A Category I furnace may be specified as Category I or III provided the installation manuals specif
17、y the venting system to be used for each category. (See 1.1.12.)i. Instructions for proper venting installation:WARNINGCARBON MONOXIDE POISONING HAZARDFailure to follow the steps outlined below for each appliance connected to the venting system being placed into operation could result in carbon mono
18、xide poisoning or death.The following steps shall be followed for each appliance connected to the venting system being placed into operation, while all other appliances connected to the venting system are not in operation:1. Seal any unused openings in the venting system.2. Inspect the venting syste
19、m for proper size and horizontal pitch, as required in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code, CSA B149.1 and these instructions. Determine that there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause
20、an unsafe condition.3. As far as practical, close all building doors and windows and all doors between the space in which the appliance(s) connected to the venting system are located and other spaces of the building.4. Close fireplace dampers.5. Turn on clothes dryers and any appliance not connected
21、 to the venting system. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they are operating at maximum speed. Do not operate a summer exhaust fan.6. Follow the lighting instructions. Place the appliance being inspected into operation. Adjust the thermostat so appliance is oper
22、ating continuously.7. Test for spillage from draft hood equipped appliances at the draft hood relief opening after 5 minutes of main burner operation. Use the flame of a match or candle.8. If improper venting is observed during any of the above tests, the venting system must be corrected in accordan
23、ce with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or Natural Gas and Propane Installation Code, CSA B149.1.9. After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace damper
24、s and any other gas-fired burning appliance to their previous conditions of use.Copyright CSA America, Inc. Provided by IHS under license with CSA/AM Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-31. For Category I furnaces, vent installations shall be in accorda
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAAMCSAANSIZ2147A2007GASFIREDCENTRALFURNACESADDENDATOTHEFIFTHEDITIONSUPERSEDEDCSAAMZ2164ACSAAMZ2164CSAAMZ2164CSAAMZ2164

链接地址:http://www.mydoc123.com/p-621073.html