CEPT T CD 02-05 E-1986 Engineering Requirements for a Bus Interface to Be Used in Data Communication Equipment《要用于数据通信设备中的总线接口工程要求》.pdf
《CEPT T CD 02-05 E-1986 Engineering Requirements for a Bus Interface to Be Used in Data Communication Equipment《要用于数据通信设备中的总线接口工程要求》.pdf》由会员分享,可在线阅读,更多相关《CEPT T CD 02-05 E-1986 Engineering Requirements for a Bus Interface to Be Used in Data Communication Equipment《要用于数据通信设备中的总线接口工程要求》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、CEPT T/CD*02-05*E Ab E 232b414 0003548 7 E Page E 1 Recommendation T/CD 02-05 (Odense 1986) ENGINEERING REQUIREMENTS FOR A BUS INTERFACE TO BE USED IN DATA COMMUNICATION EQUIPMENT Recommendation proposed by Working Group T/WG 10 ?Data communications? (CD) Text of the revised Recommendation adopted b
2、y the ?Telecommunications? Commission: ?The Conference of European Post and Telecommunications Administrations, considering - that working group CD has studied under the auspices of Question CD 1 the harmonization of Data Circuit Terminating Equipment, recommends - that the attached specification of
3、 engineering requirements for a bus interface to be used in data communication equipment as contained in Annex 1 to this Recommendation should be taken into account by all CEPT Administrations when the implementation of a relevant piece of equipment is being planned by Administrations.? Administrati
4、ons are free to stipulate additional requirements, and also which of the optional requirements, if any, are to be provided. Note 1. It should be noted that this Recommendation may be revised from time to time. Edition of April 15, 1987 CEPT T/CD*02-05* 8b H 232b4l.14 0003543 3 E T/CD 02-05 E Page 2
5、Annex 1 1. SCOPE This specification is generally applicable for use within data communication systems. Its application for specific equipment will be defined in relevant equipment specifications. These equipment specifications may also indicate which specific structures or options apply for that equ
6、ipment. 2. SYSTEM LAYOUT Three different structures are described in this specification. Selection of one of these structures is dependent on the application. - Structure I consists of one bus master unit connected to a number of bus slave units. - Structure II consists of a CENTRAL CONTROLLER conne
7、cted to a number of units, some or all of which have the capability of becoming bus master, under control of the CENTRAL CONTROLLER. - Structure III consists of a number of interconnected units, some or all of which have the capability of becoming bus master. Units negotiate this via a separate bus.
8、 Note. Units that do not have the capability to become bus master can be used in all three structures. 3. FUNCTIONAL CHARACTERISTICS The bus consists of a number of lines as listed in Table 1 (T/CD 02-05). Name Transfer control ADDRESS STROBE DATA STROBE WRITE INTERNAL ADDRESS STROBE DATAIADDRESS SO
9、URCE Master control BUS REQUEST STROBE BUS SEIZED BUS RELEASE PRIORITY Mairiterimice RESET HALT PERIPHERAL CONTROL SYSTEM CONTROL Dataladdress DATAIADDRESS ADDRESS Additionai - Abbr. AS DS WR IAS DAS BRS BS BR PR7-PRO RES HT PER SYS DA7-DAO A 15-A8 - Struct. Type TP/TS TP/TS TP/TS TP/TS oc TP/TS oc
10、TP oc TS TS - Status essential essential essential optional optional essential essential essential essential for further study for further study for further study for further study essential optional for further study Table 1 (T/CD 02-05). Bus lines. Note. For explanation of the column “type” refer
11、to section 5 of this specification. The ADDRESS STROBE line validates the signals on the DATA/ADDRESS lines DA7-DAO and poten- tially Al5.A8 as an address. The line is controlled by the bus master or by the CENTRAL CONTROLLER (structure 11). The DATA STROBE line validates the signals on the DATA/ADD
12、RESS lines as data. The line is controlled by the bus master or by the CENTRAL CONTROLLER (structure 11). Edition of April 15, 1987 4. 4.1. 4.1.1. 4.1.2. 4.1.3. - 1 CEPT T/CD*02-05*E 86 E 232bllLll 0003550 5 E T/CD 02-05 E Page 3 The WRITE line determines whether a transfer action is a read or a wri
13、te action. The line is controlled by the bus master or by the CENTRAL CONTROLLER (structure II). The INTERNAL ADDRESS STROBE line validates the signals on the DATA/ADDRESS lines as an internal address. The line is controlled by the bus master or by the CENTRAL CONTROLLER (struc- ture 11). The DATAIA
14、DDRESS SOURCE line is used to control repeaters in extended bus systems. The line is activated by the unit that activates the DATA/ADDRESS and/or ADDRESS lines. The BUS REQUEST STROBE line - in structure II validates the signals on the DATA/ADDRESS and ADDRESS fines as a bus request poll - in struct
15、ure III validates the signals on the PRIORITY and BUS SEIZED lines. This line is controlled The BUS SEIZED line - in structure II indicates that a unit has seized the bus and thus become bus master; - in structure III validates a bus request on the priority lines and initializes the transmit address
16、 procedure. The line is controlled by the master unit. The BUS RELEASE line indicates to a unit that it shall release the bus and thus cease to be the bus master, The line is controlled by the CENTRAL CONTROLLER (structure II). The PRIORITY lines detesmine which unit may become bus master. The line
17、is controlled by all units wishing to become bus master. The function of the RESET, HALT, PERIPHERAL CONTROL and SYSTEM CONTROL lines is under study. The DATAIADDRESS lines are multifunctional lines. Their function is determined by signals on STROBE lines. The ADDRESS lines contain the most signific
18、ant octet of an address when validated by the ADDRESS STROBE line. Additional lines may be defined for specific applications. Study is underway to detesmine whether some of these lines can be harmonized. address. The line is controlled by the CENTRAL CONTROLLER; by the master unit. BUS PROCEDURES Tr
19、ansfer Control The transfer control procedure is identical for all structures. Transfer actions consist of two or three different phases, the address phase, the optional internal address phase and the data phase. Address phase In this phase the bus master will apply a two octet address to the ADDRES
20、S lines (most significant octet) and the DATAIADDRESS lines (least significant octet). The master unit or the CENTRAL CONTROL- LER will activate the ADDRESS STROBE line. A unit responding to the address will enter the read/write active mode. Systems, not requiring more than 256 different addresses,
21、will not implement the optional ADDRESS lines. Internal address phase In this optional phase, the bus master will apply the internal address to the DATA/ADDRESS lines. The master unit or the CENTRAL CONTROLLER will activate the INTERNAL ADDRESS STROBE. The unit being in the read/write active mode wi
22、ll accept the internal address and regard subsequent data transfer actions as pertinent to this internal address. Theinternal address could, e,g. indicate a modem on a multiple modem unit or a timeslot in a multiplexer unit, etc. Data phase The procedure during this phase depends on whether the acti
23、on is a read or a write action, Edition of April 15, 1987 CEPT T/CD*02-05*E 6 E 2326434 0003553 7 I T/CD 02-05 E Page 4 4.1.3.1. 4.1.3.2. 4.1.4. 4.2, 4.2.1. 4,2,1,1, 4.2.1.2. 4.2.2. 4.2.2.1. Read action During a read action the master unit or the CENTRAL CONTROLLER will activate the DATA STROBE line
24、. The master unit will not activate the write line. The unit(s) being in the read/write active mode will apply a data octet to the DATA/ADDRESS lines. Write action During a write action the master unit or the CENTRAL CONTROLLER will activate the DATA STROBE line. The master unit will activate the wr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTCD0205E1986ENGINEERINGREQUIREMENTSFORABUSINTERFACETOBEUSEDINDATACOMMUNICATIONEQUIPMENT 用于 数据通信 设备

链接地址:http://www.mydoc123.com/p-593002.html