CEA-560-1990 Standard Method of Measurement for Compact Disc Players《雷射唱盘测量的标准》.pdf
《CEA-560-1990 Standard Method of Measurement for Compact Disc Players《雷射唱盘测量的标准》.pdf》由会员分享,可在线阅读,更多相关《CEA-560-1990 Standard Method of Measurement for Compact Disc Players《雷射唱盘测量的标准》.pdf(51页珍藏版)》请在麦多课文档分享上搜索。
1、 CEA Standard Standard Method of Measurement for Compact Disc Players CEA-560 R-2011 June 1990 NOTICE Consumer Electronics Association (CEA) Standards, Bulletins and other technical publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and
2、 purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards, Bulletins and other technical publications shall not in any respect preclude an
3、y member or nonmember of CEA from manufacturing or selling products not conforming to such Standards, Bulletins or other technical publications, nor shall the existence of such Standards, Bulletins and other technical publications preclude their voluntary use by those other than CEA members, whether
4、 the standard is to be used either domestically or internationally. Standards, Bulletins and other technical publications are adopted by CEA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, CEA does not assume any liability to any patent owner, nor d
5、oes it assume any obligation whatever to parties adopting the Standard, Bulletin or other technical publication. This CEA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid
6、 comparison between the CEA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health pra
7、ctices and to determine the applicability of regulatory limitations before its use. This document is copyrighted by the Consumer Electronics Association (CEA) and may not be reproduced, in whole or part, without written permission. Federal copyright law prohibits unauthorized reproduction of this do
8、cument by any means. Organizations may obtain permission to reproduce a limited number of copies by entering into a license agreement with IHS (http:/). .Requests to reproduce text, data, charts, figures or other material should be made to the CEA. (Formulated under the cognizance of the CEAs R3 Aud
9、io Systems Committee.) Published by CONSUMER ELECTRONICS ASSOCIATION 2011 Technology this represents the level of the one-third-octave filtered noise alone. Record the voltmeter reading at this point, and let N (dB) represent the reading. (d) Calculate the dynamic range according to the following fo
10、rmula: Dynamic range (dB) = A - N (e) The theoretical maximum value for a 16 bit linear PCM system with the dither and signal specified in Track 20 is 114.3 dB. Any greater value may indicate a design compromise affecting other player characteristics. 4.3.4 Measurement example: - Measurement Paramet
11、er: L : R - Dynamic Range: 105 dB : 106 dB - Test Disc: CD-1 Signal Frequency: 500 Hz Output Terminal: FIXED OUTPUT De-emphasis: OFF Table 3 4.3.5 Indication method: Follow the example below: Example: Dynamic range (EIA): 105 db or better CEA-560Page 10 Notes: 1. The channels need not be indicated.
12、2. It is not necessary to indicate that the de-emphasis is off. 4.4 Total Harmonic Distortion + Noise (THD+N) 4.4.1 Definition: The Percentage of Total Harmonic Distortion + Noise (THD+N) of a sine wave is equal to 100 times the ratio of the rms voltage measured with the fundamental component of the
13、 sine wave removed by a notch filter, to the rms voltage of the fundamental component. 4.4.2 Measuring system block diagram: 4.4.3 Test conditions: Total Harmonic Distortion + Noise (THD+N) shall be measured at 32 Hz, 63 Hz, 125 Hz, 250 Hz, 500 HZ, 1 kHz, 2 kHz, 4 kHz, 8 kHz, 10 kHz, 12.5 kHz, 16 kH
14、z, 18 kHz and 20 kHz (14 frequencies) at the O dB level. Total Harmonic Distortion + Noise (THD+N) shall also be measured at 1 kHz at the -30 dB and -60 dB levels. Inclusion of the low-pass filter shown in Figure 4 is optional. However, if a low-pass filter is used, its presence shall be indicated i
15、n the data. 4.4.4 Measurement method (a) Establish the test conditions shown in Figure 4. TEST DISC CD PLAYER BEING MEASURED LOW-PASS FILTER Figure 4 TOTAL HARMONIC DISTORTION METER CEA-560Page 11 (b) Reproducing the signals prepared for measuring THD+N (Tracks 6 through 10 and Track 18, Index 07 an
16、d 10), measure the Total Harmonic Distortion + Noise. (c) Note the presence of the low pass filter if used). CEA-560Page 12 4.4.5 Measurement example: Test Frequency : L : R 32 Hz : 0.005% : 0.005% 63 Hz : 0.005% : 0.005% 125 Hz : 0.005% : 0.005% 250 Hz : 0.005% : 0.005% 500 Hz : 0.005% : 0.005% 1 k
17、Hz : 0.005% : 0.005% 2 kHz : 0.005% : 0.005% 4 kHz : 0.005% : 0.005% 8 kHz : 0.005% : 0.005% 10 kHz : 0.005% : 0.005% 12.5 kHz : 0.007% : 0.007% 16 kHz : 0.01% : 0.01% 18 kHz : 0.02% : 0.02% 20 kHz : 0.02% : 0.02% Test Disc: CD-1 Signal Level: 0 dB Output Terminal: OUTPUT 1 De-emphasis: OFF Low-pass
18、 Filter: Used Table 4A Level : L : R -30 dB : 0.005% : 0.005% -60 dB : 0.20% : .20% Test Disc: CD-1 Signal Frequency: 1 kHz Output Terminal: FIXED OUTPUT 1 De-emphasis: OFF Low-pass Filter: Used Table 4B CEA-560Page 13 4.4.6 Indication method: Follow example below: Examples: THD+N at 0 dB (EIA) : 0.
19、005%, f 10 kHz (Low-pass Filter In) 0.02%, f 20 kH THD+N at 1 kHz (EIA): 0.005% at -30 dB (Low-pass Filter In): 0.20% at -60 dB Notes: 1. The channels need not be indicated. 2. It is not necessary to indicate that de-emphasis is off. 4.5 Channel Separation 4.5.1 Definition: Channel separation is def
20、ined as the ratio of the output signal level on one channel to the level of the fundamental component of that signal measured on the second channel, expressed in decibels. 4.5.2 Measuring system block diagram: 4.5.3 Test frequencies: 125 Hz, 1 khz, 10 kHz and 16 kHz TEST DISC CD PLAYER BEING MEASURE
21、D LOW-PASS FILTER Figure 5 VOLTMETER SPECTRUM ANALYZER CEA-560Page 14 4.5.4 Measurement method (a) Establish the test conditions shown in Figure 5. (b) Reproduce the portions of the Standard Test Disc designed for measuring Channel Separation (Tracks 2 and 3), measure the output of the reference-lev
22、el signal in the first channel, and let A (dB) represent the output reading. Simultaneously, reproduce the zero-level signal in the second channel, measure the level of the fundamental component in the second channel, and let B (dB) represent the reading. (c) Calculate the Channel Separation accordi
23、ng to the following formula: Channel Separation (dB) = A - B (d) It is recommended that a spectrum analyzer be used to measure the level of the fundamental component in the second channel. Use of a bandpass filter to measure the fundamental component in the second channel is permissible provided tha
24、t the accuracy of the reading is maintained. 4.5.5 Measurement example: Test Frequency : L R : R L 125 Hz : 83 dB : 83 dB 1kHz : 83 dB : 83 dB 4kHz : 83 dB : 83 dB 10 kHz : 68 dB : 86 dB 16 kHz : 64 dB : 63 dB Test Disc: CD-1 Signal Frequency: 1 kHz Output Terminal: OUTPUT 1 De-emphasis: OFF Low-pas
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEA5601990STANDARDMETHODOFMEASUREMENTFORCOMPACTDISCPLAYERS 雷射 唱盘 测量 标准 PDF

链接地址:http://www.mydoc123.com/p-591470.html