BS ISO 15106-7-2015 Plastics Film and sheeting Determination of water vapour transmission rate Calcium corrosion method《塑料 薄膜和薄板 水蒸汽传递率的测定 钙腐蚀方法》.pdf
《BS ISO 15106-7-2015 Plastics Film and sheeting Determination of water vapour transmission rate Calcium corrosion method《塑料 薄膜和薄板 水蒸汽传递率的测定 钙腐蚀方法》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 15106-7-2015 Plastics Film and sheeting Determination of water vapour transmission rate Calcium corrosion method《塑料 薄膜和薄板 水蒸汽传递率的测定 钙腐蚀方法》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS ISO 15106-7:2015Plastics Film and sheeting Determination of water vapourtransmission ratePart 7: Calcium corrosion methodBS ISO 15106-7:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of ISO 15106-7:2015.The UK participation in its pre
2、paration was entrusted to Technical Committee PRI/75, Plastics and rubber film and sheets.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible f
3、or its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 85831 4ICS 83.140.10Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Polic
4、y and Strategy Committee on 30 April 2015.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS ISO 15106-7:2015 ISO 2015Plastics Film and sheeting Determination of water vapour transmission rate Part 7: Calcium corrosion methodPlastiques Film et feuille Dtermination du coeffi
5、cient de transmission de vapeur deau Partie 7: Mthode de la corrosion du calciumINTERNATIONAL STANDARDISO15106-7First edition2015-04-15Reference numberISO 15106-7:2015(E)BS ISO 15106-7:2015ISO 15106-7:2015(E)ii ISO 2015 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2015All rights reserved. Unl
6、ess otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the
7、address below or ISOs member body in the country of the requester.ISO copyright officeCase postale 56 CH-1211 Geneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-mail copyrightiso.orgWeb www.iso.orgPublished in SwitzerlandBS ISO 15106-7:2015ISO 15106-7:2015(E)Foreword iv1 Scope . 12 Terms and defi
8、nitions . 13 Principle 14 Test specimens 15 Conditioning 26 Apparatus, procedure, and calculation . 27 Test conditions . 28 Test result 29 Precision . 310 Test report . 3Annex A (normative) Optical measurement method 4Annex B (normative) Electrical measurement method 6Annex C (normative) Corrosion a
9、rea evaluation method . 8Bibliography .10 ISO 2015 All rights reserved iiiContents PageBS ISO 15106-7:2015ISO 15106-7:2015(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing Internationa
10、l Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO,
11、also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1
12、. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).Attention is drawn to the possibility that some of the elem
13、ents of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations receive
14、d (see www.iso.org/patents).Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement.For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adhere
15、nce to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary informationThe committee responsible for this document is ISO/TC 61, Plastics, Subcommittee SC 11, Products.ISO 15106 consists of the following parts, under the general title Plastics F
16、ilm and sheeting Determination of water vapour transmission rate: Part 1: Humidity detection sensor method Part 2: Infrared detection sensor method Part 3: Electrolytic detection sensor method Part 4: Gas-chromatographic detection sensor method Part 5: Pressure sensor method Part 6: Atmospheric pres
17、sure ionization mass spectrometer method Part 7: Calcium corrosion methodiv ISO 2015 All rights reservedBS ISO 15106-7:2015Plastics Film and sheeting Determination of water vapour transmission rate Part 7: Calcium corrosion method1 ScopeThis part of ISO 15106 specifies a method for determining the w
18、ater vapour transmission rate of plastic film, plastic sheeting, and multi-layer structures including plastics based on measurements of calcium degradation due to the reaction with water.NOTE The method provides rapid measurement over a wide range of water vapour transmission rates.2 Terms and defin
19、itionsFor the purposes of this document, the following terms and definitions apply.2.1water vapour transmission rateamount of water vapour transmitted through unit area of test specimen per unit time under specified conditionsNote 1 to entry: Water vapour transmission rate is expressed in grams per
20、square metre per 24 h g/(m224 h).2.2seal materialadhesive materials between test specimen and glass slide for protecting the calcium film from the corrosive gas2.3encapsulantencapsulation material for protecting the calcium film from the corrosive gas3 PrincipleThe calcium test method is based on me
21、asuring the rate of reaction between calcium metal and water. A calcium film is deposited on a test specimen or a glass slide and sealed or encapsulated according to one of the three procedures described in Annex A, Annex B, and Annex C. The water vapour transmission rate is determined from the chan
22、ge of calcium film properties after exposure in an environmental chamber as described in Annex A, Annex B, and Annex C.4 Test specimens4.1 The test specimens shall be representative of the material, free from wrinkles, creases and pinholes, and have uniform thickness. Each test specimen shall have a
23、 larger area than the transmission area of the cell.4.2 Three test specimens shall be tested unless otherwise specified or agreed between the interested parties.NOTE For some products, testing more than three test specimens gives a more representative result.INTERNATIONAL STANDARD ISO 15106-7:2015(E
24、) ISO 2015 All rights reserved 1BS ISO 15106-7:2015ISO 15106-7:2015(E)5 ConditioningCondition the test specimens in vacuum or inert atmosphere. The period of conditioning shall be as stated in the relevant specification for the material.NOTE For some products, heating the test specimen is effective
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1510672015PLASTICSFILMANDSHEETINGDETERMINATIONOFWATERVAPOURTRANSMISSIONRATECALCIUMCORROSIONMETHOD

链接地址:http://www.mydoc123.com/p-584631.html