《BS ISO 15106-6-2015 Plastics Film and sheeting Determination of water vapour transmission rate Atmospheric pressure ionization mass spectrometer method《塑料 薄膜和薄板 水蒸汽传递率的测定 大气压力离子质谱法.pdf》由会员分享,可在线阅读,更多相关《BS ISO 15106-6-2015 Plastics Film and sheeting Determination of water vapour transmission rate Atmospheric pressure ionization mass spectrometer method《塑料 薄膜和薄板 水蒸汽传递率的测定 大气压力离子质谱法.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS ISO 15106-6:2015Plastics Film and sheeting Determination of water vapourtransmission ratePart 6: Atmospheric pressure ionizationmass spectrometer methodBS ISO 15106-6:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of ISO 15106-6:2015.
2、The UK participation in its preparation was entrusted to Technical Committee PRI/75, Plastics and rubber film and sheets.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a co
3、ntract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 85830 7ICS 83.140.10Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the a
4、uthority of the Standards Policy and Strategy Committee on 30 April 2015.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS ISO 15106-6:2015 ISO 2015Plastics Film and sheeting Determination of water vapour transmission rate Part 6: Atmospheric pressure ionization mass spect
5、rometer methodPlastiques Film et feuille Dtermination du coefficient de transmission de vapeur deau Partie 6: Mthode utilisant un spectromtre de masse ionisation sous pression atmosphriqueINTERNATIONAL STANDARDISO15106-6First edition2015-04-15Reference numberISO 15106-6:2015(E)BS ISO 15106-6:2015ISO
6、 15106-6:2015(E)ii ISO 2015 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2015All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the in
7、ternet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCase postale 56 CH-1211 Geneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-mail copyrightiso.orgWeb www
8、.iso.orgPublished in SwitzerlandBS ISO 15106-6:2015ISO 15106-6:2015(E)Foreword iv1 Scope . 12 Normative references 13 Terms and definitions . 14 Principle 15 Test specimens 26 Conditioning 27 Apparatus . 28 Test condition 39 Calibration graph . 410 Procedure. 511 Calculation 612 Test result 613 Prec
9、ision . 614 Test report . 6Bibliography 8 ISO 2015 All rights reserved iiiContents PageBS ISO 15106-6:2015ISO 15106-6:2015(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing Internationa
10、l Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO,
11、also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1
12、. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).Attention is drawn to the possibility that some of the elem
13、ents of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations receive
14、d (see www.iso.org/patents).Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement.For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adhere
15、nce to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary informationThe committee responsible for this document is ISO/TC 61, Plastics, Subcommittee SC 11, Products.ISO 15106 consists of the following parts, under the general title Plastics F
16、ilm and sheeting Determination of water vapour transmission rate: Part 1: Humidity detection sensor method Part 2: Infrared detection sensor method Part 3: Electrolytic detection sensor method Part 4: Gas-chromatographic detection sensor method Part 5: Pressure sensor method Part 6: Atmospheric pres
17、sure ionization mass spectrometer method Part 7: Calcium corrosion methodiv ISO 2015 All rights reservedBS ISO 15106-6:2015Plastics Film and sheeting Determination of water vapour transmission rate Part 6: Atmospheric pressure ionization mass spectrometer method1 ScopeThis part of ISO 15106 specifie
18、s a method for determining the water vapour transmission rate of plastic film, plastic sheeting, and multi-layer structures including plastics, using an atmospheric pressure ionization mass spectrometric detection sensor.NOTE The method provides rapid measurement over a wide range of water vapour tr
19、ansmission rates.2 Normative referencesThe following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (inc
20、luding any amendments) applies.ISO 6145-8, Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 8: Diffusion method3 Terms and definitionsFor the purposes of this document, the following terms and definitions apply.3.1water vapour transmission rateamount of wate
21、r vapour transmitted through unit area of test specimen per unit time under specified conditionsNote 1 to entry: Water vapour transmission rate is expressed in grams per square metre per 24 h g/(m224 h).4 PrincipleThe gas transmission cell is designed in such a way that, with the test specimen inser
22、ted, it is divided into a dry chamber and a wet chamber. The dry side of the specimen is swept by a flow of dry carrier gas such as nitrogen or argon, and water vapour permeating through the specimen from the wet chamber is carried by the carrier gas into an atmospheric pressure ionization mass spec
23、trometer. This sensor contains an ion formation region near atmospheric pressure and a mass analysis region in ultra-high vacuum. The carrier gas with the moisture is introduced into the ion formation region where the carrier gas is ionized as primary ions by corona discharge ion sources, and then,
24、an ion-molecule reaction is produced between the primary ions and water molecules contained in the carrier gas and the water molecules are ionized. These ionized water molecules are fed to the mass analysis region. Water vapour content in the range between ppt and ppb in the carrier gas can be detec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1510662015PLASTICSFILMANDSHEETINGDETERMINATIONOFWATERVAPOURTRANSMISSIONRATEATMOSPHERICPRESSUREIONIZATIONMASSSPECTROMETERMETHOD

链接地址:http://www.mydoc123.com/p-584630.html