BS ISO 14242-3-2009 Implants for surgery - Wear of total hip-joint prostheses - Loading and displacement parameters for orbital bearing type wear testing machines and corresponding.pdf
《BS ISO 14242-3-2009 Implants for surgery - Wear of total hip-joint prostheses - Loading and displacement parameters for orbital bearing type wear testing machines and corresponding.pdf》由会员分享,可在线阅读,更多相关《BS ISO 14242-3-2009 Implants for surgery - Wear of total hip-joint prostheses - Loading and displacement parameters for orbital bearing type wear testing machines and corresponding.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BS ISO14242-3:2009ICS 11.040.40NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDImplants for surgery Wear of total hip-jointprosthesesPart 3: Loading and displacementparameters for orbital bearingtype wear testing machines andcorresponding environmentalconditions
2、 for testThis British Standardwas published underthe authority of theStandards Policy andStrategy Committee on 30November 2009 BSI 2009ISBN 978 0 580 57753 6Amendments/corrigenda issued since publicationDate CommentsBS ISO 14242-3:2009National forewordThis British Standard is the UK implementation o
3、f ISO 14242-3:2009.The UK participation in its preparation was entrusted to TechnicalCommittee CH/150/4, Bone and joint replacements.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisi
4、onsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.BS ISO 14242-3:2009Reference numberISO 14242-3:2009(E)ISO 2009INTERNATIONAL STANDARD ISO14242-3First edition2009-03-15Implants for surgery Wear of total
5、 hip-joint prostheses Part 3: Loading and displacement parameters for orbital bearing type wear testing machines and corresponding environmental conditions for test Implants chirurgicaux Usure des prothses totales de larticulation de la hanche Partie 3: Paramtres de charge et de dplacement pour mach
6、ines dessai dusure du type orbital de maintien et conditions environnementales correspondantes dessai BS ISO 14242-3:2009ISO 14242-3:2009(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be ed
7、ited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a
8、trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member b
9、odies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2009 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by an
10、y means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail
11、copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2009 All rights reservedBS ISO 14242-3:2009ISO 14242-3:2009(E) ISO 2009 All rights reserved iiiContents Page Foreword iv Introduction v 1 Scope . 1 2 Normative references . 1 3 Terms and definitions. 1 4 Principle. 2 5 Reagents and tes
12、t specimens . 2 6 Apparatus 3 7 Procedure 6 8 Test report . 7 9 Disposal of test specimen . 8 Bibliography . 9 BS ISO 14242-3:2009ISO 14242-3:2009(E) iv ISO 2009 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodie
13、s (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations,
14、 governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO
15、/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the m
16、ember bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 14242-3 was prepared by Technical Committee ISO/TC 150, Implants for
17、 surgery, Subcommittee SC 4, Bone and joint replacements. ISO 14242 consists of the following parts, under the general title Implants for surgery Wear of total hip-joint prostheses: Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for t
18、est Part 2: Methods of measurement Part 3: Loading and displacement parameters for orbital bearing type wear testing machines and corresponding environmental conditions for test BS ISO 14242-3:2009ISO 14242-3:2009(E) ISO 2009 All rights reserved vIntroduction The orbital bearing hip wear simulator (
19、OBM) is widely used and has been successful in evaluating the wear properties of Total Hip Arthroplasty (THA) articulating surfaces. These test results have been shown to correlate well with clinical experience. Since this type of test machine is widely used, it is important that the parameters be s
20、tandardized to make the results more uniform and comparable between laboratories. This test method differs from that in ISO 14242-1 in the articulating motion of the test. Although the motion of the OBM is simpler and less anatomic than the motion described in ISO 14242-1, OBM hip simulators have be
21、en used to evaluate the wear of THA articulating components for more than 25 years. The equipment is used globally for wear testing of THA components, and has been very successful in reproducing the types and amounts of wear that occur in vivo with a wide variety of bearing materials, including poly
22、ethylene, metals and ceramics. Because of this, tests on OBM machines have provided very accurate predictions of the subsequent clinical performance of newly developed materials. This is particularly true for the new crosslinked polyethylenes. Several recent reports with more than five years of foll
23、ow up have shown percent reductions in wear, compared to historical polyethylene, that are very close to those that were predicted as much as ten years earlier in tests run on OBM hip simulators. BS ISO 14242-3:2009BS ISO 14242-3:2009INTERNATIONAL STANDARD ISO 14242-3:2009(E) ISO 2009 All rights res
24、erved 1Implants for surgery Wear of total hip-joint prostheses Part 3: Loading and displacement parameters for orbital bearing type wear testing machines and corresponding environmental conditions for test 1 Scope This part of ISO 14242 specifies relative angular movement between articulating compon
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1424232009IMPLANTSFORSURGERYWEAROFTOTALHIPJOINTPROSTHESESLOADINGANDDISPLACEMENTPARAMETERSFORORBITALBEARINGTYPEWEARTESTINGMACHINESANDCORRESPONDINGPDF

链接地址:http://www.mydoc123.com/p-584371.html