1、BS ISO 11171:2016Hydraulic fluid power Calibration of automaticparticle counters for liquidsBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS ISO 11171:2016 ISO 2016Hydraulic fluid power Calibration of automatic particle counters for liquidsTransmissions hydraulique
2、s talonnage des compteurs automatiques de particules en suspension dans les liquidesINTERNATIONALSTANDARDISO11171Third edition2016-10-01Reference numberISO 11171:2016(E)BS ISO 11171:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of ISO 11171:2016. It supersedes
3、BS ISO 11171:2010 which is withdrawn.Attention is drawn to the fact that the UK committee voted against the approval of this International Standard.The UK committee has concerns that there are three options for presenting data which will give significant differences in particle counts when analysing
4、 the same fluid with automatic particle counters (APCs). The difference in particle counts is because the previous calibration suspensions, SRM 2806 and 2806a, where the calibrated size is labelled “m(c)”, are no longer available. The latest characterization of the particle sizes by electron microsc
5、ope has shown that there is an increase in size of the same particles. The result is that calibration using SRM 2806b results in higher particle counts compared to calibration using SRM 2806 or SRM 2806a, when testing the same fluid.Clause 6.8 of this standard describes the process for constructing
6、an additional calibration curve so that an APC calibrated using SRM 2806b can give results equivalent to the earlier standard that used SRM 2806 or SRM 2806a when option 7.1 b) is selected, but use of this is not required when reporting to options 7.1 a) and 7.1 c).Any standard using APCs calibrated
7、 to ISO 11171 will be affected by these changes e.g. ISO 4406. It is beyond the scope of this standard to state how to apply the results derived in clause 7.1 to generate ISO 4406 codes. At the time of publication, ISO 4406 has not been revised to account for these changes and the UK committee sugge
8、sts, therefore, that the ISO Code is followed by: “m” if option 7.1 a) is chosen; “m(c)” if option 7.1 b) is chosen, or “m(b)” if option 7.1 c) is chosen.The UK participation in its preparation was entrusted by Technical Committee MCE/18, Fluid power systems and components, to Subcommittee MCE/18/-/
9、6, Contamination control.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution
10、2016. Published by BSI Standards Limited 2016ISBN 978 0 580 92671 6ICS 23.100.60; 75.120Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2016.Amendment
11、s/corrigenda issued since publicationDate Text affectedBS ISO 11171:2016 ISO 2016Hydraulic fluid power Calibration of automatic particle counters for liquidsTransmissions hydrauliques talonnage des compteurs automatiques de particules en suspension dans les liquidesINTERNATIONAL STANDARDISO11171Thir
12、d edition2016-10-01Reference numberISO 11171:2016(E)BS ISO 11171:2016ISO 11171:2016(E)ii ISO 2016 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2016, Published in SwitzerlandAll rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in
13、any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCh. de Bla
14、ndonnet 8 CP 401CH-1214 Vernier, Geneva, SwitzerlandTel. +41 22 749 01 11Fax +41 22 749 09 47copyrightiso.orgwww.iso.orgBS ISO 11171:2016ISO 11171:2016(E)Foreword ivIntroduction v1 Scope . 12 Normative references 13 Terms and definitions . 14 Materials and equipment 25 Sequence of APC calibration pr
15、ocedures 46 Sizing calibration procedure 77 Data presentation .138 Identification statement 14Annex A (normative) Preliminary APC check 15Annex B (normative) Coincidence error procedure 18Annex C (normative) Flow rate limit determination 23Annex D (normative) Resolution determination 27Annex E (norm
16、ative) Verification of particle-counting accuracy 32Annex F (normative) Preparation and verification of bottles of secondary calibration suspensions .35Annex G (informative) APC calibration round robin .38Annex H (informative) Sample calculations.43Annex I (informative) Verification of particle size
17、 distribution of calibration samples 49Bibliography .51 ISO 2016 All rights reserved iiiContents PageBS ISO 11171:2016ISO 11171:2016(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing In
18、ternational Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison
19、with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directiv
20、es, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some
21、of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarati
22、ons received (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement.For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about
23、 ISOs adherence to the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following URL: www.iso.org/iso/foreword.html. The committee responsible for this document is ISO/TC 131, Fluid power systems, Subcommittee SC 6, Contamination control.This third edition
24、cancels and replaces the second edition (ISO 11171:2010), of which it constitutes a minor revision.This edition includes the following significant changes with respect to the previous edition: 6.8: defining m equation, Table 3 revised to show m(b) and m(c) to be reported; 7.1: revised to show how to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO111712016HYDRAULICFLUIDPOWERCALIBRATIONOFAUTOMATICPARTICLECOUNTERSFORLIQUIDS 液压 传动 液体 自动 粒子 计数器

链接地址:http://www.mydoc123.com/p-583492.html