1、BRITISH STANDARD AEROSPACE SERIES BS G243:1990 Specification for Igniter cables for engine use (4kV d.c.)BSG243:1990 This BritishStandard having beenprepared under the directionof theAerospace Standards Policy Committee (ACE/-) was published undertheauthority of the BoardofBSIand comes into effect o
2、n 31August1990 BSI01-2000 The following BSI references relate to the work on this standard: Committee reference ACE/6 Draft for comment88/71918DC ISBN 0 580 18036 0 Committees responsible for this BritishStandard The preparation of this BritishStandard was entrusted by the Aerospace Standards Commit
3、tee (ACE/-) to Technical Committee ACE/6, upon which the following bodies were represented: BEAMA Ltd. British Cable Makers Confederation British Rubber Manufacturers Association Civil Aviation Authority Electronic Components Industry Federation Ministry of Defence National Supervising Inspectorate
4、Society of British Aerospace Companies Limited Amendments issued since publication Amd. No. Date of issue CommentsBSG243:1990 BSI 01-2000 i Contents Page Committees responsible Insidefrontcover Foreword ii 1 Scope 1 2 Construction 1 3 Designation and marking 1 4 Packaging and labelling 1 5 Performan
5、ce 1 6 Testing 1 Appendix A Hot dielectric test 6 Appendix B Thermal shock test 6 Figure 1 Cable 1 Table 1 Cable properties 2 Table 2 Cable test requirements 2 Table 3 Test application 4 Publications referred to Inside back coverBSG243:1990 ii BSI 01-2000 Foreword This BritishStandard, which has bee
6、n prepared under the direction of the Aerospace Standards Policy Committee, specifies requirements for a range of aircraft engine ignition cables that are suitable for use on high energy ignition circuits working at voltages of not more than4kV d.c. It is intended to be read in conjunction with BS G
7、 230 “General requirements for aircraft electrical cables (second series)” which specifies the general requirements and test methods for this range of cables. The standard requires the selection of the dielectric material so as to provide the minimum penalties of weight and space whilst offering rel
8、iable performance, and the dielectric insulation material should be suitable for printed identity marking methods. Cables manufactured to this standard are not required to meet BS3G 100, subsection3-13, Resistance to fire in designated fire zones. Care should be taken to select terminations which ha
9、ve been declared as suitable for use with the cable specified in this BritishStandard. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of i
10、tself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to6, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be ind
11、icated in the amendment table on the inside front cover.BSG243:1990 BSI 01-2000 1 1 Scope This BritishStandard specifies the physical properties and performance requirements for high energy igniter cables of sizes030 and050 which are suitable for working at voltages of not more than4kV d.c. The cabl
12、es are suitable for continuous use where the maximum stabilized conductor temperature does not exceed260 C, and for applications involving flexing at temperatures down to65 C. NOTE 1The latest revision of an Aerospace standard is indicated by the prefix number. NOTE 2The titles of the publications r
13、eferred to in this standard are listed on the inside back page. 2 Construction 2.1 General The materials and method of construction used for the formation of the cables shall be defined and controlled to the satisfaction of the Approving Authority 1) . No change shall be made to such materials or pr
14、ocesses unless it can be shown to the satisfaction of the Approving Authority that the performance and handling properties of the cable have not been degraded. 2.2 Conductors 2.2.1 Conductors used in the manufacture of this cable shall comply with BS G 231. 2.2.2 Copper strands shall be nickel-plate
15、d (seeFigure 1). 2.3 Insulation 2.3.1 The insulation shall consist of two or more contrawrapped lapped layers of polytetrafluoroethylene (PTFE) tape sintered into an homogeneous mass (seeFigure 1). 2.3.2 The insulation shall not be loose on the conductor but it shall be possible to strip the insulat
16、ion from the conductor leaving the latter in a sufficiently clean condition to permit satisfactory connections to be made to terminations. 2.4 Properties Cable properties shall be in accordance with Table 1. 2.5 Colour The colour of the finished cable shall be white. 3 Designation and marking The de
17、signation and marking of the cable shall comply with clause4 of BSG 230:1984. 4 Packaging and labelling The packaging and labelling of cable shall comply with clause5 of BSG 230:1984. 5 Performance When tested in accordance with6.1 the cable shall comply with the specific requirements given in Table
18、 2. 6 Testing 6.1 Cable shall be tested in accordance with Table 2. Test methods shall comply with BS G 230. 6.2 The application of tests for qualification approval, production quality testing, inspection lot testing and production routine testing shall be in accordance with Table 3. Test methods sh
19、all comply with BS G 230. 1) The Approving Authority shall be either: a) for UK civil aviation products, the Civil Aviation Authority (or their accredited representative); or b) for UK military products, the Quality Assurance Directorate nominated in the relevant Ministry of Defence contract. Figure
20、 1 CableBSG243:1990 2 BSI 01-2000 Table 1 Cable properties Table 2 Cable test requirements Cable designation Size code Conductor (nominal) Maximum resistance Minimum insulation thickness Cable diameter Maximum mass per unit length Area No. of wires Wire diameter Conductor diameter maximum minimum BS
21、 G 243 030 mm 22.98 37 mm 0.32 mm 2.24 Ohms/Km 6.44 mm 0.725 mm 3.94 mm 3.69 g/m 45.2 BS G 243 050 4.65 37 0.4 2.8 4.08 0.9 4.8 4.6 68.6 BS G 230Test No. Purpose of test Specific requirements of this standard 1 Appearance and identification of finished cable As BSG 230 2 Mass per unit length of fini
22、shed cable Maximum values shall be in accordance with Table 1 of this standard 3 Conductor composition As BSG 230 4 Visual examination of strands As BSG 230 5 Insulation thickness and concentricity Minimum values shall be in accordance with Table 1 of this standard 6 Core and cable outer diameters D
23、imensions shall be in accordance with Table 1 of this standard 7 Tensile strength and elongation at break of copper or copper alloy conductors Tensile strength shall be220N/mm 2(minimum)300N/mm 2(maximum) Elongation shall be10%(minimum). 9 Strand plating continuity As BSG 230 10 Strand plating adher
24、ence As BSG 230 11 Strand plating thickness As BSG 230 12 Electrical resistance of copper or copper alloy conductors Maximum values shall be in accordance with Table 1 of this standard 15 Conductors strand adhesion As BSG 230 16 High voltage As BSG 230 16(a) 16(b) Immersion Dry spark Test voltage5kV
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSG2431990SPECIFICATIONFORIGNITERCABLESFORENGINEUSE4KVDC 发动机 点火 电缆 规范 KV 直流 PDF

链接地址:http://www.mydoc123.com/p-582837.html