BS EN 61391-2-2010 Ultrasonics - Pulse-echo scanners - Measurement of maximum depth of penetration and local dynamic range《超音波 脉冲回波扫描器 最大穿透深度和局部动态范围的测量》.pdf
《BS EN 61391-2-2010 Ultrasonics - Pulse-echo scanners - Measurement of maximum depth of penetration and local dynamic range《超音波 脉冲回波扫描器 最大穿透深度和局部动态范围的测量》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61391-2-2010 Ultrasonics - Pulse-echo scanners - Measurement of maximum depth of penetration and local dynamic range《超音波 脉冲回波扫描器 最大穿透深度和局部动态范围的测量》.pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationUltrasonics Pulse-echo scannersPart 2: Measurement of maximum depth of penetration and local dynamic rangeBS EN 61391-2:2010National forewordThis British Standard is the UK imple
2、mentation of EN 61391-2:2010. It isidentical to IEC 61391-2:2010.The UK participation in its preparation was entrusted to Technical CommitteeEPL/87, Ultrasonics.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to inclu
3、de all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 58266 0ICS 17.140.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy a
4、nd Strategy Committee on 31 July 2010.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61391-2:2010EUROPEAN STANDARD EN 61391-2 NORME EUROPENNE EUROPISCHE NORM April 2010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation
5、 Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61391-2:2010 E ICS 17.140.50 English version Ultrasonic
6、s - Pulse-echo scanners - Part 2: Measurement of maximum depth of penetration and local dynamic range (IEC 61391-2:2010) Ultrasons - Scanners impulsion et cho - Partie 2 : Mesure de la profondeur maximale de pntration et de la plage dynamique locale (CEI 61391-2:2010) Ultraschall - Impuls-Echo-Scann
7、er - Teil 2: Messung der maximalen Eindringtiefe und des lokalen Dynamikbereichs (IEC 61391-2:2010) This European Standard was approved by CENELEC on 2010-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Stan
8、dard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, Fre
9、nch, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium,
10、 Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN
11、 61391-2:2010EN 61391-2:2010 - 2 - Foreword The text of document 87/400/CDV, future edition 1 of IEC 61391-2, prepared by IEC TC 87, Ultrasonics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61391-2 on 2010-04-01. Attention is drawn to the possibility that some of
12、 the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national
13、 standard or by endorsement (dop) 2011-01-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-04-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61391-2:2010 was approved by CENELEC as a Europea
14、n Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60601-1:2005 NOTE Harmonized as EN 60601-1:2006 (not modified). IEC 61161:1992 NOTE Harmonized as EN 61161:1994 (not modified). _ BS EN 61391-2:2010-
15、3 - EN 61391-2:2010 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated refe
16、rences, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 61391-1 2006 Ultrasonics - Pulse-echo scan
17、ners - Part 1: Techniques for calibrating spatial measurement systems and measurement of system point spread function response EN 61391-1 2006 IEC 62127-1 2007 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz EN 62127-1 2007 BS EN 61391-2
18、:2010 2 61391-2 IEC:2010(E) CONTENTS INTRODUCTION.61 Scope.82 Normative references .83 Terms and definitions .84 General requirement.135 Environmental conditions136 Equipment and data required146.1 General .146.2 Phantoms146.2.1 Phantoms required 146.2.2 Phantom for maximum depth of penetration.146.
19、2.3 Phantoms to estimate local dynamic range 156.3 Test equipment for measuring local dynamic range .156.4 Digitized image data177 Measurement methods .197.1 System sensitivity: maximum depth of penetration.197.1.1 Scanning system settings 197.1.2 Image acquisition 197.1.3 Analysis.207.2 Local dynam
20、ic range .227.2.1 Scanning system settings 227.2.2 Measurement method 227.2.3 Type II testing for measuring local dynamic range .237.2.4 Estimating local dynamic range using backscatter contrast24Annex A (informative) Phantom for determining maximum depth of penetration .26Annex B (informative) Loca
21、l dynamic range using acoustical test objects.28Bibliography35Figure 1 Arrangement for measuring local dynamic range using an acoustic-signal injection technique16Figure 2 Arrangement for measuring local dynamic range using an acoustically-coupled burst generator 17Figure 3 Image of the penetration
22、phantom20Figure 4 Mean digitized image data value vs. depth for the phantom image data (A(j) and for the noise image data (A(j) 21Figure 5 Digitized-image data vs. attenuator setting during local dynamic range measurements using acoustic signal injection.23Figure 6 Image of phantom with inclusions (
23、circles) .24Figure 7 Ensemble-average mean pixel value vs. backscatter contrast of inclusions25Figure A.1 Phantom for maximum depth of penetration tests26Figure B.1 Possible arrangement of reflectors for determining local dynamic range .29Figure B.2 Displayed intensity (or image pixel value) vs. ref
24、lector reflection coefficient .30Figure B.3 Flat ended wire test object for determining local dynamic range32BS EN 61391-2:201061391-2 IEC:2010(E) 3 Figure B.4 The experimentally observed backscattering cross section of flat-ended stainless-steel wires as a function of diameter for three frequencies
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6139122010ULTRASONICSPULSEECHOSCANNERSMEASUREMENTOFMAXIMUMDEPTHOFPENETRATIONANDLOCALDYNAMICRANGE

链接地址:http://www.mydoc123.com/p-577477.html