BS EN 61100-1993 Classification of insulating liquids according to fire point and net calorific value《根据燃点和净热值对绝缘液体进行的分类》.pdf
《BS EN 61100-1993 Classification of insulating liquids according to fire point and net calorific value《根据燃点和净热值对绝缘液体进行的分类》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61100-1993 Classification of insulating liquids according to fire point and net calorific value《根据燃点和净热值对绝缘液体进行的分类》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 61100:1993 IEC 1100:1992 Classification of insulating liquids according to fire point and net calorific value The European Standard EN61100:1992 has the status of a BritishStandard UDC 621.315.615:536.4:614.83BSEN61100:1993 This BritishStandard, having been prepared under the
2、directionof the Cables and Insulation Standards Policy Committee, was published underthe authority of the Standards Board and comes intoeffect on 15March1993 BSI 12-1999 The following BSI references relate to the work on this standard: Committee reference CIL/10 Special announcement BSINews October1
3、992 ISBN 0 580 21983 6 Cooperating organizations The European Committee for Electrotechnical Standardization (CENELEC), under whose supervision this European Standard was prepared, comprises the national committees of the following countries: Austria Italy Belgium Luxembourg Denmark Netherlands Finl
4、and Norway France Portugal Germany Spain Greece Sweden Iceland Switzerland Ireland UnitedKingdom Amendments issued since publication Amd. No. Date CommentsBSEN61100:1993 BSI 12-1999 i Contents Page Cooperating organizations Inside front cover National foreword ii Foreword 2 Text of EN61100 3 Nationa
5、l annex NA (informative) Committees responsible Inside back cover National annex NB (informative) Cross-references Inside back coverBSEN61100:1993 ii BSI 12-1999 National foreword This BritishStandard has been prepared under the direction of the Cables and Insulation Standards Policy Committee and i
6、s the English language version of EN61100:1992 Classification of insulating liquids according to fire point and net calorific value, published by the European Committee for Electrotechnical Standardization (CENELEC). It is identical with IEC1100:1992 published by the International Electrotechnical C
7、ommission (IEC). A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This do
8、cument comprises a front cover, an inside front cover, pagesi andii, theEN title page, pages2 to6, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front co
9、ver.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61100 July 1992 UDC621.315.615:536.4:614.83 Descriptors: Liquid electrical insulating materials, classification, fire point, calorific value, designation English version Classification of insulating liquids according to fire point and net calo
10、rific value (IEC1100:1992) Classification des isolants liquides selon le point de feu et le pouvoir calorifique infrieur (CEI1100:1992) Klassifikation von Isolierflssigkeiten nach dem Brandverhalten und unteren Heizwert (IEC1100:1992) This European Standard was approved by CENELEC on1992-03-24. CENE
11、LEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on a
12、pplication to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secre
13、tariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and UnitedKingdom. CENELEC
14、European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1992 Copyright reserved to CENELEC members Ref.No.EN61100:1992EEN61100:1992 BSI 12-1999 2
15、Foreword The text of document10(CO)261, as prepared by IEC Technical Committee No10: Fluids for electrotechnical applications, was submitted to the IEC-CENELEC parallel vote in July1991. The reference document was approved by CENELEC as EN61100 on24 March1992. The following dates were fixed: Annexes
16、 designated “normative” are part of the body of the standard. In this standard, Annex ZA is normative. Contents Page Foreword 2 Introduction 3 1 Scope 3 2 Normative references 3 3 Characteristics selected for the classification 3 3.1 Fire-point 3 3.2 Net calorific value 3 4 Classification 4 4.1 Clas
17、sification according to fire-point 4 4.2 Classification according to net calorific value 4 4.3 Examples of designation 4 Annex ZA (normative) Other international publications quoted in this standard with the references of the relevant European publications 5 latest date of publication of an identica
18、l national standard (dop)1993-05-01 latest date of withdrawal of conflicting national standards (dow)1993-05-01EN61100:1992 BSI 12-1999 3 Introduction IEC Publication76-2:1976, Power transformers Part2: Temperature rise, includes a classification system for identifying transformers based on type of
19、cooling medium and the method of coolant circulation. Insulating liquids were classified therein according to their fire behaviour into classesO (mineral oil or equivalent combustible synthetic insulating liquids), and L (non-flammable synthetic insulating liquids). In1984, IEC/TC10 undertook a clas
20、sification of insulating liquids according to fire behaviour. Pending IEC/TC10 proposals, CENELEC/TC14 drafted such a classification based on fire-point adding to the former classes O and L a new class K for liquids with fire-point above300 C. While the value of fire-point to indicate the relative e
21、ase of ignition of a liquid is widely recognized, the degree of fire hazard depends on the rate of heat release during a fire. Therefore, it seemed desirable to include an additional classification property related to the heat energy generated by the liquid during its combustion. The classification
22、system of insulating liquids described in this standard uses two fire-related characteristics: fire-point and net calorific value. When suitable, internationally standardized methods for the determination of heat release or other characteristics of fire behaviour become available, they may be incorp
23、orated in this classification. The intention is not to provide a complete evaluation of all aspects of fire hazard, neither to establish an order of merit of insulating liquid, but only to set in the same class those liquids that may require similar type and amount of safeguards for fire protection.
24、 1 Scope This International Standard defines a system for classifying insulating liquids according to fire-point and net calorific value. The characteristics on which the system is based are given together with limiting values. 2 Normative references The following standards contain provisions which,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN611001993CLASSIFICATIONOFINSULATINGLIQUIDSACCORDINGTOFIREPOINTANDNETCALORIFICVALUE 根据 燃点 热值 绝缘 液体

链接地址:http://www.mydoc123.com/p-576855.html