BS EN 60512-15-5-2008 Connectors for electronic equipment - Tests and measurements -Part 15-5 Connector tests (mechanical) - Test 15e - Contact retention in insert cable nutation《电.pdf
《BS EN 60512-15-5-2008 Connectors for electronic equipment - Tests and measurements -Part 15-5 Connector tests (mechanical) - Test 15e - Contact retention in insert cable nutation《电.pdf》由会员分享,可在线阅读,更多相关《BS EN 60512-15-5-2008 Connectors for electronic equipment - Tests and measurements -Part 15-5 Connector tests (mechanical) - Test 15e - Contact retention in insert cable nutation《电.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 60512-15-5:2008Connectors for electronic equipment Tests and measurements Part 15-5: Connector tests (mechanical) Test 15e: Contact retention in insert, cable nutationICS 31.220.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g
2、40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 60512-15-5:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2008 BSI 2008ISBN 978 0 580 55903 7National forewordThis B
3、ritish Standard is the UK implementation of EN 60512-15-5:2008. It is identical to IEC 60512-15-5:2008.The UK participation in its preparation was entrusted to Technical Committee EPL/48, Electromechanical components and mechanical structures for electronic equipment.A list of organizations represen
4、ted on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments/cor
5、rigenda issued since publicationDate CommentsEUROPEAN STANDARD EN 60512-15-5 NORME EUROPENNE EUROPISCHE NORM July 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat:
6、 rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60512-15-5:2008 E ICS 31.220.10 English version Connectors for electronic equipment - Tests and measurements - Part 15-5: Connector tests
7、(mechanical) - Test 15e: Contact retention in insert, cable nutation (IEC 60512-15-5:2008) Connecteurs pour quipements lectroniques - Essais et mesures - Partie 15-5: Essais (mcaniques) des connecteurs - Essai 15e: Rtention du contact dans lisolant par nutation du cble (CEI 60512-15-5:2008) Steckver
8、binder fr elektronische Einrichtungen - Mess- und Prfverfahren - Teil 15-5: Mechanische Prfungen an Steckverbindern - Prfung 15e: Kontakthalterung im Einsatz - Kabelbeanspruchung (IEC 60512-15-5:2008) This European Standard was approved by CENELEC on 2008-07-01. CENELEC members are bound to comply w
9、ith the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secreta
10、riat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the
11、 official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Por
12、tugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 48B/1847/FDIS, future edition 1 of IEC 60512-15-5, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic equipment, was s
13、ubmitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60512-15-5 on 2008-07-01. This standard is to be read in conjunction with EN 60512-1 and EN 60512-1-100 which explains the structure of the EN 60512 series. The following dates were fixed: latest date by which the EN has to
14、be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-07-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the Inte
15、rnational Standard IEC 60512-15-5:2008 was approved by CENELEC as a European Standard without any modification. _ BS EN 60512-15-5:2008 2 CONNECTORS FOR ELECTRONIC EQUIPMENT TESTS AND MEASUREMENTS Part 15-5: Connector tests (mechanical) Test 15e: Contact retention in insert, cable nutation 1 Scope a
16、nd object This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this document is to detail a standard test method to
17、 verify the capability of the contact retention system to withstand dynamic mechanical loading of the contacts that tends to dislodge them. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited a
18、pplies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60512-1-1, Connectors for electronic equipment Tests and measurements Part 1-1: General examination Test 1a: Visual examination IEC 60512-2-5: Connectors for electronic equipment Tes
19、ts and measurements Part 2-5: Electrical continuity and contact resistance tests Test 2e: Contact disturbance 3 Preparations 3.1 Preparation of specimen The specimen shall consist of a connector with its terminations. Any accessories, which do not form part of the contact system, may be removed. Any
20、 preconditioning given in the detail specification shall be applied. The contacts to be tested shall be attached to a flexible stranded steel cable of a diameter suitable for attachment to the contact under test and to support the specified mass shown on Figure 1. If specified in the detail specific
21、ation, a specified copper or other cable may be used. NOTE It may be necessary to enlarge the end of the cable before attachment to the contact(s), in order to prevent the cable pulling out of the contact during testing. Where the connector has four or more contacts, three contacts shall be selected
22、 at random provided that two contacts shall be near periphery and one near the centre of the connector insert or housing. All other contacts shall be installed. In the case where a corresponding connector is to be used, this shall have all contacts installed. BS EN 60512-15-5:2008 3 3.2 Equipment Te
23、st apparatus such as that shown in Figure 1 shall be provided. The mass shall be sufficient to provide tension in the cable without deforming the specimen under test. Unless otherwise stated in the detail specification, this shall be 1,4 kg 0,02 kg. NOTE 1 If the detail specification requires specia
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN605121552008CONNECTORSFORELECTRONICEQUIPMENTTESTSANDMEASUREMENTSPART155CONNECTORTESTSMECHANICALTEST15ECONTACTRETENTIONININSERTCABLENUTATION

链接地址:http://www.mydoc123.com/p-575793.html