BS EN 60068-3-2-1999 Environmental testing - Guidance - Combined temperature low air pressure tests - Combined temperature low air pressure tests《环境试验 指南 组合温度 低气压试验》.pdf
《BS EN 60068-3-2-1999 Environmental testing - Guidance - Combined temperature low air pressure tests - Combined temperature low air pressure tests《环境试验 指南 组合温度 低气压试验》.pdf》由会员分享,可在线阅读,更多相关《BS EN 60068-3-2-1999 Environmental testing - Guidance - Combined temperature low air pressure tests - Combined temperature low air pressure tests《环境试验 指南 组合温度 低气压试验》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD Environmental testing - Part 3: Background information - Section 2: Combined temperaturehow air pressure tests The European Standard EN 6O0683-21999 has the status of a British Standard ICs 19.040 BS EN 6068-3-2: 1999 IEC 60068-3-2:1976 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PE
2、RMITTED BY COPYRIGHT LAW National foreword direction of the Electrotechnicai Amd. No. Da Sector Committee, was published This British Standard is the English language version of EN 6006852: 1999. It is identical with IEC 600683-2:19976. It supersedes BS 20113WAM is still a very small fraction of the
3、 resulting dimensions. STD-BSI BS EN bOOb8-3-2-ENGL 1999 m Lb24bb9 0792959 243 m Page 6 EN 60068-3-2:1999 3. Environmental effects 3.1 The following effects on a specimen are considered to be due to the combination of temperature and low air pressure: a) increase of surface temperature and changes o
4、f temperature gradients of heat-dissipating specimens in comparison with the values achieved with Tests A or B are due to the decrease of the convection coefficient ae, at low air pressure (low air density). Although the increase of surface temperatures can be achieved by using a higher test tempera
5、ture at normal air pressure, this test temperature value cannot be properly established and the correct temperature gradients cannot be achieved without combining with low air pressure; b) changes in functional or safety characteristics of specimens due to changes with pressure and temperature of di
6、electric properties of air (air density and ion mobility effects). At low pressures, particularly when combined with high temperature, there is a marked reduction of air dielectric strength with the consequent increased risk of arc, surface or corona discharges. Table I gives multiplying factors for
7、 obtaining sparkover voltages for plane and parallel electrodes with air gaps greater than 5 mm. The factors convert values at standard conditions (25 “C and 1 013 mbar) to the pressures and temperatures given in the table. TABLE I 1 I r Temperature in degrees Celsius Pressure (mbar) - 20 O 20 40 60
8、 I70 340 510 675 850 0.26 0.24 0.23 0.21 0.20 0.19 0.47 O .44 0.42 0.39 0.31 0.24 0.68 0.64 0.60 0.56 0.53 0.50 0.87 0.82 0.77 0.72 0.68 0.64 1 .O7 0.99 0.93 0.87 0.82 0.17 c) changes in material characteristics (brittleness, plasticity) due to cold or heat increase the risk that sealed equipments o
9、r packages will be deformed or cracked at low air pressures. 3.2 Other effects due essentially to temperature but remarkably accelerated by low air pressures (so that a test at normal air pressure can give the same effects only after a very long test time) are: a) volatilization of plasticizers and
10、of degradation products from plastics, with changes in the mechanical and electrical characteristics of individual parts of the specimen; these evaporated products can, in addition, condense on nearby surfaces, producing changes of characteristics or corrosion and degradation; b) evaporation of lubr
11、icants with consequent blocking of moving parts; this process can be exaggerated by dimensional changes due to temperature; c) dissolved gas evolution from liquids; the reduced pressure can result in transitory boiling, with a possible leakage of liquid. At much lower air pressures (such as the ones
12、 existing in outer space), other phenomena become very important. A special testing philosophy must then be used for these latter conditions. 4. Testing facilities The composition of the atmosphere in the testing chamber is generally not truly representative of the natural conditions. The compositio
13、n is determined essentially by the type of pumps used to reduce the air pressure. A con- biderable quantity of water vapour is generally present (the humidity can be measured by a dew point instrument). Page 6 EN 60068-3 - 2: 1999 The error in the convection coefficient a, due to differences between
14、 natural and simulated air composition is The following factors are more important for possible side effects on specimens being tested: not more than 10%. a) chamber atmosphere contamination from vapours of the pump working fluid and from vapours released from chamber accessories (valves, heat insul
15、ators, etc.); b) contamination by dust or water introduced by the air when pressure is restored to normal. 5. Measurements of environmental parameters 5.1 Temperature measurements air temperature monitoring is reduced by the a, decrease. The efficiency of thermal exchange between test atmosphere and
16、 sensing elements of the thermometer used for As a consequence: a) the response time of thermometers to temperature changes is greater than at normal pressure; b) errors due to the thermal conduction between the thermometer and the chamber exterior can become important. In testing of heat-dissipatin
17、g specimens, there is another measurement error (caused by the reduced a, value) which may be larger at low air pressure than at normal air pressure; the thermometer can give incorrect readings if affected by energy radiated from the specimen. The use of radiation shields around the thermometer can
18、reduce this error. 5.2 Air pressure measurements In the pressure range under consideration, the pressure inside the chamber is generally measured with man- ometers connected to the working space by tubes. In stationary conditions, such tubes do not result in significant measurement errors even for l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN60068321999ENVIRONMENTALTESTINGGUIDANCECOMBINEDTEMPERATURELOWAIRPRESSURETESTSCOMBINEDTEMPERATURELOWAIRPRESSURETESTS

链接地址:http://www.mydoc123.com/p-575227.html